222 research outputs found

    Study on the clinical application of pulsed DC magnetic technology for tracking of intraoperative head motion during frameless stereotaxy

    Get PDF
    BACKGROUND: Tracking of post-registration head motion is one of the major problems in frameless stereotaxy. Various attempts in detecting and compensating for this phenomenon rely on a fixed reference device rigidly attached to the patient's head. However, most of such reference tools are either based on an invasive fixation technique or have physical limitations which allow mobility of the head only in a restricted range of motion after completion of the registration procedure. METHODS: A new sensor-based reference tool, the so-called Dynamic Reference Frame (DRF) which is designed to allow an unrestricted, 360° range of motion for the intraoperative use in pulsed DC magnetic navigation was tested in 40 patients. Different methods of non-invasive attachment dependent on the clinical need and type of procedure, as well as the resulting accuracies in the clinical application have been analyzed. RESULTS: Apart from conventional, completely rigid immobilization of the head (type A), four additional modes of head fixation and attachment of the DRF were distinguished on clinical grounds: type B1 = pin fixation plus oral DRF attachment; type B2 = pin fixation plus retroauricular DRF attachment; type C1 = free head positioning with oral DRF; and type C2 = free head positioning with retroauricular DRF. Mean fiducial registration errors (FRE) were as follows: type A interventions = 1.51 mm, B1 = 1.56 mm, B2 = 1.54 mm, C1 = 1.73 mm, and C2 = 1.75 mm. The mean position errors determined at the end of the intervention as a measure of application accuracy were: 1.45 mm in type A interventions, 1.26 mm in type B1, 1.44 mm in type B2, 1.86 mm in type C1, and 1.68 mm in type C2. CONCLUSION: Rigid head immobilization guarantees most reliable accuracy in various types of frameless stereotaxy. The use of an additional DRF, however, increases the application scope of frameless stereotaxy to include e.g. procedures in which rigid pin fixation of the cranium is not required or desired. Thus, continuous tracking of head motion allows highly flexible variation of the surgical strategy including intraoperative repositioning of the patient without impairment of navigational accuracy as it ensures automatic correction of spatial distortion. With a dental cast for oral attachment and the alternative option of non-invasive retroauricular attachment, flexibility in the clinical use of the DRF is ensured

    Search for Charginos with a Small Mass Difference with the Lightest Supersymmetric Particle at \sqrt{s} = 189 GeV

    Get PDF
    A search for charginos nearly mass-degenerate with the lightest supersymmetric particle is performed using the 176 pb^-1 of data collected at 189 GeV in 1998 with the L3 detector. Mass differences between the chargino and the lightest supersymmetric particle below 4 GeV are considered. The presence of a high transverse momentum photon is required to single out the signal from the photon-photon interaction background. No evidence for charginos is found and upper limits on the cross section for chargino pair production are set. For the first time, in the case of heavy scalar leptons, chargino mass limits are obtained for any \tilde{\chi}^{+-}_1 - \tilde{\chi}^0_1 mass difference

    Intraoperative electrocortical stimulation of Brodman area 4: a 10-year analysis of 255 cases

    Get PDF
    BACKGROUND: Brain tumor surgery is limited by the risk of postoperative neurological deficits. Intraoperative neurophysiological examination techniques, which are based on the electrical excitability of the human brain cortex, are thus still indispensable for surgery in eloquent areas such as the primary motor cortex (Brodman Area 4). METHODS: This study analyzed the data obtained from a total of 255 cerebral interventions for lesions with direct contact to (121) or immediately adjacent to (134) Brodman Area 4 in order to optimize stimulation parameters and to search for direct correlation between intraoperative potential changes and specific surgical maneuvers when using monopolar cortex stimulation (MCS) for electrocortical mapping and continuous intraoperative neurophysiological monitoring. RESULTS: Compound muscle action potentials (CMAPs) were recorded from the thenar muscles and forearm flexors in accordance with the large representational area of the hand and forearm in Brodman Area 4. By optimizing the stimulation parameters in two steps (step 1: stimulation frequency and step 2: train sequence) MCS was successful in 91% (232/255) of the cases. Statistical analysis of the parameters latency, potential width and amplitude showed spontaneous latency prolongations and abrupt amplitude reductions as a reliable warning signal for direct involvement of the motor cortex or motor pathways. CONCLUSION: MCS must be considered a stimulation technique that enables reliable qualitative analysis of the recorded potentials, which may thus be regarded as directly predictive. Nevertheless, like other intraoperative neurophysiological examination techniques, MCS has technical, anatomical and neurophysiological limitations. A variety of surgical and non-surgical influences can be reason for false positive or false negative measurements

    A Twenty-First Century Assessment of Values Across the Global

    Get PDF
    This article provides current Schwartz Values Survey (SVS) data from samples of business managers and professionals across 50 societies that are culturally and socioeconomically diverse. We report the society scores for SVS values dimensions for both individual- and societallevel analyses. At the individual-level, we report on the ten circumplex values sub-dimensions and two sets of values dimensions (collectivism and individualism; openness to change, conservation, self-enhancement, and self- transcendence). At the societal-level, we report on the values dimensions of embeddedness, hierarchy, mastery, affective autonomy, intellectual autonomy, egalitarianism, and harmony. For each society, we report the Cronbach’s a statistics for each values dimension scale to assess their internal consistency (reliability) as well as report interrater agreement (IRA) analyses to assess the acceptability of using aggregated individual level values scores to represent country values. We also examined whether societal development level is related to systematic variation in the measurement and importance of values. Thus, the contributions of our evaluation of the SVS values dimensions are two-fold. First, we identify the SVS dimensions that have cross-culturally internally reliable structures and withinsociety agreement for business professionals. Second, we report the society cultural values scores developed from the twenty-first century data that can be used as macro-level predictors in multilevel and single-level international business research

    Helminth Communities of Owls (Strigiformes) Indicate Strong Biological and Ecological Differences from Birds of Prey (Accipitriformes and Falconiformes) in Southern Italy

    Get PDF
    We compared the helminth communities of 5 owl species from Calabria (Italy) and evaluated the effect of phylogenetic and ecological factors on community structure. Two host taxonomic scales were considered, i.e., owl species, and owls vs. birds of prey. The latter scale was dealt with by comparing the data here obtained with that of birds of prey from the same locality and with those published previously on owls and birds of prey from Galicia (Spain). A total of 19 helminth taxa were found in owls from Calabria. Statistical comparison showed only marginal differences between scops owls (Otus scops) and little owls (Athene noctua) and tawny owls (Strix aluco). It would indicate that all owl species are exposed to a common pool of 'owl generalist' helminth taxa, with quantitative differences being determined by differences in diet within a range of prey relatively narrow. In contrast, birds of prey from the same region exhibited strong differences because they feed on different and wider spectra of prey. In Calabria, owls can be separated as a whole from birds of prey with regard to the structure of their helminth communities while in Galicia helminths of owls represent a subset of those of birds of prey. This difference is related to the occurrence in Calabria, but not Galicia, of a pool of 'owl specialist' species. The wide geographical occurrence of these taxa suggest that local conditions may determine fundamental differences in the composition of local communities. Finally, in both Calabria and Galicia, helminth communities from owls were species-poor compared to those from sympatric birds of prey. However, birds of prey appear to share a greater pool of specific helmith taxa derived from cospeciation processes, and a greater potential exchange of parasites between them than with owls because of phylogenetic closeness

    Assessment of a continuous blood gas monitoring system in animals during circulatory stress

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions</p> <p>Methods</p> <p>Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Arginine-vasopressin 4, 8 and 16 IU/h), hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia), and volume resuscitation were induced in ten swine (57.4 ± 10.7 Kg).Intermittent blood gas assessments were carried out using a routine gas analyzer at any experimental phase and compared with values obtained at the same time settings during continuous monitoring with CDI™ 500 system. The Bland-Altman analysis was employed.</p> <p>Results</p> <p>Bias and precision for pO<sub>2 </sub>were - 0.06 kPa and 0.22 kPa, respectively (r<sup>2 </sup>= 0.96); pCO<sub>2 </sub>- 0.02 kPa and 0.15 kPa, respectively; pH -0.001 and 0.01 units, respectively ( r<sup>2 </sup>= 0.96). The analysis showed very good agreement for SO<sub>2 </sub>(bias 0.04,precision 0.33, r<sup>2 </sup>= 0.95), Base excess (bias 0.04,precision 0.28, r<sup>2 </sup>= 0.98), HCO<sub>3 </sub>(bias 0.05,precision 0.62, r<sup>2 </sup>= 0.92),hemoglobin (bias 0.02,precision 0.23, r<sup>2 </sup>= 0.96) and K<sup>+ </sup>(bias 0.02, precision 0.27, r<sup>2 </sup>= 0.93). The sensor was reliable throughout the experiment during hemodynamic variations.</p> <p>Conclusions</p> <p>Continuous blood gas analysis with the CDI™ 500 system was reliable and it might represent a new useful tool to accurately and timely monitor gas exchange in critically ill patients. Nonetheless, our findings need to be confirmed by larger studies to prove its reliability in the clinical setting.</p
    corecore