10 research outputs found
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Liquid xenon time projection chambers are promising detectors to search for
neutrinoless double beta decay (0), due to their response
uniformity, monolithic sensitive volume, scalability to large target masses,
and suitability for extremely low background operations. The nEXO collaboration
has designed a tonne-scale time projection chamber that aims to search for
0 of \ce{^{136}Xe} with projected half-life sensitivity of
~yr. To reach this sensitivity, the design goal for nEXO is
1\% energy resolution at the decay -value (~keV).
Reaching this resolution requires the efficient collection of both the
ionization and scintillation produced in the detector. The nEXO design employs
Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm
scintillation light of liquid xenon. This paper reports on the characterization
of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3
SiPMs specifically designed for nEXO, as well as new measurements on new test
samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters
(MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct
crosstalk, correlated avalanches and photon detection efficiency were measured
as a function of the applied over voltage and wavelength at liquid xenon
temperature (163~K). The results from this study are used to provide updated
estimates of the achievable energy resolution at the decay -value for the
nEXO design
The novel Mechanical Ventilator Milano for the COVID-19 pandemic
This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world
The novel Mechanical Ventilator Milano for the COVID-19 pandemic
This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Multi-Pixel Photon Counters (MPPC)s as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various MPPC features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. MPPCs were characterized in the range 163Kâ€Tâ€233K. At an over voltage of 3.1±0.2 V and at T=163K we report a number of Correlated Avalanches (CAs) per pulse in the 1ÎŒs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137±0.002Hz/mm2. Both the number of CAs and the DN rate ar
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
© 2019 Elsevier B.V.In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Multi-Pixel Photon Counters (MPPC)s as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various MPPC features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. MPPCs were characterized in the range 163Kâ€Tâ€233K. At an over voltage of 3.1±0.2 V and at T=163K we report a number of Correlated Avalanches (CAs) per pulse in the 1ÎŒs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137±0.002Hz/mm2. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at T=233K for a mean wavelength of 189±7nm. At 3.6±0.2 V and 3.5±0.2 V of over voltage we report a PDE of 13.4±2.6% and 11±2%, corresponding to a saturation PDE of 14.8±2.8% and 12.2±2.3%, respectively. Both values are well below the 24% saturation PDE advertised by Hamamatsu. More generally, the second device tested at 3.5±0.2 V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF Silicon Photo-Multipliers for the final design of the nEXO detector11sciescopu
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0 of \ce{^{136}Xe} with projected half-life sensitivity of ~yr. To reach this sensitivity, the design goal for nEXO is 1% energy resolution at the decay -value (~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay -value for the nEXO design
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0 of \ce{^{136}Xe} with projected half-life sensitivity of ~yr. To reach this sensitivity, the design goal for nEXO is 1% energy resolution at the decay -value (~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay -value for the nEXO design