25 research outputs found

    Unexpected discovery of surgical gauze during a robotic radical prostatectomy identified as a capturing lymph node on magnetic resonance

    Get PDF
    Multiparametric magnetic resonance, plays a crucial role in several steps of the management of prostate cancer. Various factors could alter the interpretation and reduce the accuracy of MR. Among these the group of the retained surgical items, can produce serious implications for the health of patient, as well as medical-legal consequences. Here we report the case of a patient, with a prostate tumor, who performed a mp-MRI of the prostate, where it was reported as collateral finding, compatible thesis with lymphadenopathy. During robotic assisted radical prostatectomy, was found a gauze, which persisted asymptomatic, retained after a previous right inguinal hernioplast

    Penile lenghthening original technique using a pubo-cavernous spacer. Long term results from a series of over 200 patients

    Get PDF
    Introduction: We report our long experience in the surgical treatment of patients requesting penile lengthening by suspensory ligament release and placement of a custom-made soft silicone pubo-cavernous spacer. The aim was to show that with this surgical technique the results obtained are maintained over time. It is crucial to achieve postoperative satisfaction of these patients who show fragility and self-esteem problems. Methods: From 1999 to 2020, we treated 245 patients with congenital or acquired penile brevity. We carefully analysed the preoperative and postoperative (at 6, 12, 24 and 48 months) penile size of the patients to evaluate whether this technique could allow the long-term maintenance of aesthetic results. We also assessed preoperative erectile function and we focused on the psychological aspects to avoid surgery in patients with dysmorphophobia. This original technique involves the section of the suspensory ligament and the implantation of a silicone spacer between the pubic symphysis and the corpora cavernosa. This spacer is conformed to the patient anatomy and maintains the relationship between the anatomical structures unchanged over time. Sexual self-esteem and patient satisfaction were assessed with the APPSSI questionnaire. Results: The mean increase in penile length was about 2.5 cm in flaccid state and 1.9 cm in stretched state. There were no injuries of the neurovascular bundle or urethra, and no erectile dysfunction was noted. These results persisted at 6, 12, 24 and 48 months without significant differences. Over 80% of patients stated that they were completely satisfied with the results obtained. This satisfaction remained stable along follow up. Conclusion: The section of the suspensory ligament and the implant of the soft silicone spacer provide real penis elongation with satisfactory results that persist over time. This technique avoids the frequent complication of short-term shortening due to the scar adhesions of the edges of the dissected ligament. The high aesthetic satisfaction of patients is stable at controls at 6, 12, 24 and 48 months

    Cribriform pattern does not have a significant impact in Gleason Score ≥7/ISUP Grade ≥2 prostate cancers submitted to radical prostatectomy

    Get PDF
    The aim of this study was to correlate cribriform pattern (CP) with other parameters in a large prospective series of Gleason score ≥7/ISUP grade ≥2 prostate cancer (PC) cases undergoing radical prostatectomy (RP)

    Impact of uni- or multifocal perineural invasion in prostate cancer at radical prostatectomy

    Get PDF
    Background: Aim of this study was to correlate perineural invasion (PNI) with other clinical-pathological parameters in terms of prognostic indicators in prostate cancer (PC) cases at the time of radical prostatectomy (RP). Methods: Prospective study of 288 consecutive PC cases undergoing RP. PNI determination was performed either in biopsy or in RP specimens classifying as uni- and multifocal PNI. The median follow-up time was 22 (range, 6-36) months. Results: At biopsy PNI was found in 34 (11.8%) cases and in 202 (70.1%) cases at the time of surgery. Among those identified at RP 133 (46.1%) and 69 (23.9%) cases had uni- and multi-PNI, respectively. Presence of PNI was significantly (P<0.05) correlated with unfavorable pathological parameters such higher stage and grade. The percentage of extracapsular extension in PNI negative RP specimens was 18.6% vs. 60.4% of PNI positive specimens. However, the distribution of pathological staging and International Society of Urological Pathology (ISUP) grading did not vary according to whether PNI was uni- or multifocal. The risk of biochemical progression increased 2.3 times in PNI positive cases was significantly associated with the risk of biochemical progression (r=0.136; P=0.04). However, at multivariate analysis PNI was not significantly associated with biochemical progression [hazard ratio (HR): 1.87, 95% confidence interval (CI): 0.68-3.12; P=0.089]. Within patients with intermediate risk disease, multifocal PNI was able to predict cases with lower mean time to biochemical and progression free survival (chi-square 5.95; P=0.04). Conclusions: PNI at biopsy is not a good predictor of the PNI incidence at the time of RP. PNI detection in surgical specimens may help stratify intermediate risk cases for the risk of biochemical progression

    MoS2 photoelectrodes for hydrogen production: Tuning the S-vacancy content in highly homogeneous ultrathin nanocrystals

    Full text link
    Tuning the electrocatalytic properties of MoS2 layers can be achieved through different paths, such as reducing their thickness, creating edges in the MoS2 flakes, and introducing S-vacancies. We combine these three approaches by growing MoS2 electrodes by using a special salt-assisted chemical vapor deposition (CVD) method. This procedure allows the growth of ultrathin MoS2 nanocrystals (1-3 layers thick and a few nanometers wide), as evidenced by atomic force microscopy and scanning tunneling microscopy. This morphology of the MoS2 layers at the nanoscale induces some specific features in the Raman and photoluminescence spectra compared to exfoliated or microcrystalline MoS2 layers. Moreover, the S-vacancy content in the layers can be tuned during CVD growth by using Ar/H2 mixtures as a carrier gas. Detailed optical microtransmittance and microreflectance spectroscopies, micro-Raman, and X-ray photoelectron spectroscopy measurements with sub-millimeter spatial resolution show that the obtained samples present an excellent homogeneity over areas in the cm2 range. The electrochemical and photoelectrochemical properties of these MoS2 layers were investigated using electrodes with relatively large areas (0.8 cm2). The prepared MoS2 cathodes show outstanding Faradaic efficiencies as well as long-term stability in acidic solutions. In addition, we demonstrate that there is an optimal number of S-vacancies to improve the electrochemical and photoelectrochemical performances of MoS2PID2021-126098OB-I00, PID2020-116619GA-C22, TED2021-131788A-I00, SI3/PJI/2021-0050

    Comparison of laparoscopic partial nephrectomy performed with AirSeal® system vs. standard insufflator: results from a referral center

    Get PDF
    ObjectiveTo compare perioperative and oncologic surgical outcomes during laparoscopic partial nephrectomy (LPN) performed by standard carbon dioxide insufflation, with those from surgeries in which the AirSeal® intelligent insufflation system was used for renal tumors.Materials and methodsA total of 27 patients with renal tumor were identified, 14 underwent LPN with AirSeal® (group A) and 13 LPN with standard insufflator (group B), respectively. Demographic baseline characteristics were similar in the two groups.ResultsThe size of the tumor was largest in group B (29.64 vs. 32.1 mm). The mean operative time was shorter in the AirSeal® group [group A: mean 109.0 min, median 107.5 min, interquartile range (IQR) 85; group B: mean 121.0 min, median 120.0 min, IQR 50.0]. Positive margin rates were absent in the two groups. Estimated blood loss presented a difference in the perioperative period (group A: mean 1.5 g/dL, median 1.45 g/dL; group B: mean 2.15 g/dL, median 2.2 g/dL). Time to ischemia was found to be shorter in group A with a median of 18 min compared to a median of 20 min in group B. No subcutaneous emphysema, pneumothorax, and pneumomediastinum cases occurred in either group. A postoperative complication developed in one patient requiring superselective embolization.ConclusionIn selected patients, our preliminary surgical experience has shown that the LPN procedure performed with the aid of the AirSeal® intelligent insufflation system can be used to treat even medium-/high-complexity kidney lesions, with a reduction in operating times, lower rates of complications, and perioperative blood loss.Clinical trial registrationAirSealV1

    Enzyme-Containing Paints Inhibit the Growth of Marine Microorganisms

    No full text
    A new strategy to prevent the biofouling of water-submerged surfaces is presented here. In particular, the authors show that carbonic anydrase from Methanosarcina thermophila can be entrapped into polyacrylic paints, preserving enzyme activity. In addition, the authors also show that enzyme-containing paints inhibit the growth of marine microorganims, preventing biofouling

    Influence of COVID-19 pandemic on timing and outcomes of treatment for acute testicular torsion in adults: a single institution experience

    No full text
    Introduction: The worldwide spread of SARS-COV2 had led to a delay in treatment of numerous urological pathologies, even in emergency conditions. We therefore sought to determine whether the timing of diagnosis and treatment and the postoperative outcome of patients with testicular torsion had been changed during the COVID pandemic. Materials and methods: We considered all patients evaluated in the emergency department (ED) for testicular torsion from February 2018 to August 2019 (pre-COVID period) and from February 2020 to August 2021 (during COVID pandemic). All patients underwent clinical and ultrasound evaluation and subsequently scrotal exploration. Primary outcomes were the time differences from pain onset to ED presentation and from ED presentation to surgical treatment. We also investigated whether the number or orchiectomies required changed during the pandemic. Results: A total of 54 patients were divided in two groups: 40 patients in pre-COVID-19 group and 14 in the COVID-19 cohort. Mean time from symptoms onset to ED access was longer during the pandemic (4.2 ± 5.7 versus 39.6 ± 37.3 hours, p = 0.009). Mean time from ED access to surgery was similar (2.9 ± 1.1 versus 4.2 ± 2.3, p = 0.355). In addition, the number of orchiectomies was higher in COVID-19 group (2.5% versus 28.6%, p < 0.01), compared to a lower number of detorsions (97.5% versus 71.4%, p < 0.01). Elapsed time from pain onset to surgery was directly correlated with the increased white blood cell (WBC) count after surgery (r = 0.399, p = 0.002). Discussion and conclusions: The current study identifies a significant delay in presentation of testicular torsion which resulted in a significant increase in orchiectomies with the expected decreased in detorsion/orchiopexy. In addition, there was an increase in the WBC at presentation associated with delayed presentation

    A standardization of Amphibalanus (Balanus) amphitrite (Crustacea, Cirripedia) larval bioassay for ecotoxicological studies

    No full text
    A series of 10 intra-laboratory bioassays and an inter-laboratory assay involving nine laboratories, were performed to validate the use of Amphibalanus amphitrite larvae as test organisms for ecotoxicological studies. The standardization protocol utilized Cadmium Nitrate as a reference toxicant and larval immobilization (after 24 and 48 h) as the end-point. The statistical data analysis showed high homogeneity in intra-laboratory EC50 values among bioassay repetitions (coefficient of variation (CV)= 15.8% after 24 h and 16.9% after 48 h); also CV values obtained in inter laboratory comparison exercise were not higher than the 50%, variation coefficient mentioned in the ISO standards for the precision of inter-laboratory assays. The results demonstrated that the protocol implemented for the balanus larval bioassay comply with the international standards both for intra- and inter-laboratory precision. (C) 2012 Elsevier Inc. All rights reserved

    Homogeneous spatial distribution of Deuterium chemisorbed on free-standing graphene

    No full text
    Atomic deuterium (D) adsorption on free-standing nanoporous graphene obtained by ultra-high vacuum D2 molecular cracking reveals a homogeneous distribution all over the nanoporous graphene sample, as deduced by ultra-high vacuum Raman spectroscopy combined with core-level photoemission spectroscopy. Raman microscopy unveils the presence of bonding distortion, from the signal associated to the planar sp2 configuration of graphene toward the sp3 tetrahedral structure of graphane. The establishment of D-C sp3 hybrid bonds is also clearly determined by high-resolution X-ray photoelectron spectroscopy and spatially correlated to the Auger spectroscopy signal. This work shows that the low-energy molecular cracking of D2 in an ultra-high vacuum is an efficient strategy for obtaining high-quality semiconducting graphane with homogeneous uptake of deuterium atoms, as confirmed by this combined optical and electronic spectro-microscopy study wholly carried out in ultra-high vacuum conditions
    corecore