8 research outputs found

    Mir-23b down-regulates the expression of target gene of acetaldehyde dehydrogenase 1a1 and increases the sensitivity of cervical cancer stem cells to cisplatin

    Get PDF
    Purpose: To study the effect of miR-23b on the expression of the target gene of acetaldehyde dehydrogenase 1A1 (ALDH1A1), and cisplatin (CDDP) susceptibility of cervical carcinoma stem cells. Methods: Human cervical cancer cell line Hela cells were cultured in vitro, and miR-23b mimic and negative control were transfected into the cells using lipofectamine method. The growth of the two groups of cells was determined using growth curve method, and their proliferation measured using plate clone formation. The influence of treatments on the sensitivity of the cells to CDDP was assayed using MTT method. The mRNA expression of ALDH1A1 in Hela cells was assayed using real-time quantitative polymerase hain reation (PCR), while its protein expression was assayed by Western blot. Results: The levels of expressions of ALDH1A1 protein and mRNA in the miR-23b overexpression group were significantly lower than those in the control group (p < 0.05). The sensitivities of Hela cells to CDDP in the ALDH1A1 inhibition group and the control group were dose-dependent to some extent, but cell inhibition in ALDH1A1 inhibition group markedly increased, relative to control when the CDDP dose was 0.1 ppc (p < 0.01). Conclusion: Up-regulating the expression of miR-23b significantly inhibits the growth and proliferation of cervical cancer cells, and increases their sensitivity to CDDP via down-regulation of the expression of the target gene for ALDH1A1. Therefore, during cervical carcinoma treatment, increasing the level of miR-23b may produce a chemotherapeutic effect. Keywords: MiR-23b, Acetaldehyde dehydrogenase 1A1, Cervical cancer, Cisplatin, Sensitivit

    Coronary stent implantation links to the occurrence of eosinophilia and interstitial pneumonia: a case report and systematic review

    No full text
    Abstract Background Rapamycin has been extensively utilized for coating coronary artery stents to reduce the occurrence of restenosis, yet there has been limited research on the potential harms of rapamycin-eluting stents. Herein, We report a case of eosinophilia and interstitial pneumonia caused by a cobalt-based alloy stent eluted with rapamycin. Case presentation The patient was admitted due to fever, cough, and expectoration symptoms. Previously, the patient had undergone a procedure of percutaneous coronary stent implantation in our hospital’s cardiology department, which led to a gradual rise in blood eosinophil count. This time, the eosinophil count was higher than the previous admission. A chest CT scan revealed multiple flocculent density increases in both lungs and bronchiectasis. The rapamycin-eluting stents may have caused eosinophilia and interstitial pneumonia, which improved after administering corticosteroids. A systematic review of relevant literature was conducted to summarize the characteristics of interstitial pneumonia caused by drug-eluting stents. Conclusion Paclitaxel, everolimus, zotarolimus, and rapamycin are the types of drugs that can lead to drug-eluting stents, and because of the rarity of their onset, clinical doctors must be precise and prompt in diagnosing suspected cases to avoid misdiagnosis and delayed treatment

    Diagnostic accuracy of thoracic CT to differentiate transudative from exudative pleural effusion prior to thoracentesis

    No full text
    Abstract Background Computed tomography (CT) scan is commonly performed for pleural effusion diagnostis in the clinic. However, there are limited data assessing the accuracy of thoracic CT for the separation of transudative from exudative effusions. The study aimed to determine the diagnostic value of thoracic CT in distinguishing transudates from exudates in patients with pleural effusion. Methods This is a two-center retrospective analysis of patients with pleural effusion, a total of 209 patients were included from The First Affiliated Hospital of Henan University of Science and Technology as the derivation cohort (Luoyang cohort), and 195 patients from the First Affiliated Hospital of Zhengzhou University as the validation cohort (Zhengzhou cohort). Patients who underwent thoracic CT scan followed by diagnostic thoracentesis were enrolled. The optimal cut-points of CT value in pleural fluid (PF) and PF to blood CT value ratio for predicting a transudative vs. exudative pleural effusions were determined in the derivation cohort and further verified in the validation cohort. Results In the Derivation (Luoyang) cohort, patients with exudates had significantly higher CT value [13.01 (10.01–16.11) vs. 4.89 (2.31–9.83) HU] and PF to blood CT value ratio [0.37 (0.27–0.53) vs. 0.16 (0.07–0.26)] than those with transudates. With a cut-off value of 10.81 HU, the area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CT value were 0.85, 88.89%, 68.90%, 43.96%, and 95.76%, respectively. The optimum cut-value for PF to blood CT value ratio was 0.27 with AUC of 0.86, yielding a sensitivity of 61.11%, specificity of 86.36%, PPV of 78.57%, and NPV of 73.08%. These were further verified in the Validation (Zhengzhou) cohort. Conclusions CT value and PF to blood CT value ratio showed good differential abilities in predicting transudates from exudates, which may help to avoid unnecessary thoracentesis
    corecore