19 research outputs found

    De novoCIAS1 mutations, cytokine activation, and evidence for genetic heterogeneity in patients with neonatal-onset multisystem inflammatory disease (NOMID): A new member of the expanding family of pyrin-associated autoinflammatory diseases

    Get PDF
    Neonatal-onset multisystem inflammatory disease (NOMID; also known as chronic infantile neurologic, cutaneous, articular [CINCA] syndrome) is characterized by fever, chronic meningitis, uveitis, sensorineural hearing loss, urticarial skin rash, and a characteristic deforming arthropathy. We investigated whether patients with this disorder have mutations in CIAS1, the gene which causes Muckle-Wells syndrome and familial cold autoinflammatory syndrome, two dominantly inherited disorders with some similarities to NOMID/CINCA syndrome

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Current worldwide nuclear cardiology practices andradiationexposure: results from the 65 country IAEA nuclear cardiology protocols cross-sectional study (INCAPS)

    Get PDF
    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiationoptimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposurewere identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally

    Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries

    Get PDF
    Purpose: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. Methods: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 – 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). Results: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. Conclusion: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice

    Comparison of Radiation Doses and Best-Practice Use for Myocardial Perfusion Imaging in US and Non-US Laboratories: Findings From the IAEA (International Atomic Energy Agency) Nuclear Cardiology Protocols Study

    Get PDF
    not availabl

    Estimating the Reduction in the Radiation Burden From Nuclear Cardiology Through Use of Stress-Only Imaging in the United States and Worldwide

    Get PDF
    Not availabl

    Profile of Fatty Acids, Tocopherols, Phytosterols and Polyphenols in Mediterranean Oils (Argan Oils, Olive Oils, Milk Thistle Seed Oils and Nigella Seed Oil) and Evaluation of their Antioxidant and Cytoprotective Activities

    No full text

    Worldwide Diagnostic Reference Levels for Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging: Findings From INCAPS

    No full text
    Objectives: This study sought to establish worldwide and regional diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Background: Reference levels serve as radiation dose benchmarks to compare individual laboratories against aggregated data, helping to identify sites in greatest need of dose reduction interventions. DRLs for SPECT MPI have previously been derived from national or regional registries. To date there have been no multiregional reports of DRLs for SPECT MPI from a single standardized dataset. Methods: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study), a cross-sectional, multinational registry of MPI protocols. A total of 7,103 studies were included. DRLs and AAAs were calculated by protocol for each world region and for aggregated worldwide data. Results: The aggregated worldwide DRLs for rest-stress or stress-rest studies employing technetium Tc 99m–labeled radiopharmaceuticals were 11.2 mCi (first dose) and 32.0 mCi (second dose) for 1-day protocols, and 23.0 mCi (first dose) and 24.0 mCi (second dose) for multiday protocols. Corresponding AAAs were 10.1 mCi (first dose) and 28.0 mCi (second dose) for 1-day protocols, and 17.8 mCi (first dose) and 18.7 mCi (second dose) for multiday protocols. For stress-only technetium Tc 99m studies, the worldwide DRL and AAA were 18.0 mCi and 12.5 mCi, respectively. Stress-first imaging was used in 26% to 92% of regional studies except in North America where it was used in just 7% of cases. Significant differences in DRLs and AAAs were observed between regions. Conclusions: This study reports reference levels for SPECT MPI for each major world region from one of the largest international registries of clinical MPI studies. Regional DRLs may be useful in establishing or revising guidelines or simply comparing individual laboratory protocols to regional trends. Organizations should continue to focus on establishing standardized reporting methods to improve the validity and comparability of regional DRLs

    Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols

    No full text
    Objectives: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED). Background: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols. Methods: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED. Results: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv. Conclusions: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions

    Impact of age on the selection of nuclear cardiology stress protocols: The INCAPS (IAEA nuclear cardiology protocols) study

    No full text
    Background: There is growing concern about radiation exposure from nuclear myocardial perfusion imaging (MPI), particularly among younger patients who are more prone to develop untoward effects of ionizing radiation, and hence US and European professional society guidelines recommend age as a consideration in weighing radiation risk from MPI. We aimed to determine how patient radiation doses from MPI vary across age groups in a large contemporary international cohort. Methods: Data were collected as part of a global cross-sectional study of centers performing MPI coordinated by the International Atomic Energy Agency (IAEA). Sites provided information on each MPI study completed during a single week in March–April 2013. We compared across age groups laboratory adherence to pre-specified radiation-related best practices, radiation effective dose (ED; a whole-body measure reflecting the amount of radiation to each organ and its relative sensitivity to radiation's deleterious effects), and the proportion of patients with ED ≤ 9 mSv, a target level specified in guidelines. Results: Among 7911 patients undergoing MPI in 308 laboratories in 65 countries, mean ED was 10.0 ± 4.5 mSv with slightly higher exposure among younger age groups (trend p value < 0.001). There was no difference in the proportion of patients with ED ≤ 9 mSv across age groups, or in adherence to best practices based on the median age of patients in a laboratory. Conclusions: In contemporary nuclear cardiology practice, the age of the patient appears not to impact protocol selection and radiation dose, contrary to professional society guidelines
    corecore