    Diagnostic value of PET-measured heterogeneity in myocardial blood flows during cold pressor testing for the identification of coronary vasomotor dysfunction

    Get PDF
    Background: We aimed to evaluate the diagnostic value of a positron emission tomography (PET)-measured heterogeneity in longitudinal myocardial blood flow (MBF) during cold pressor testing (CPT) and global MBF response to CPT from rest (ΔMBF) for identification of coronary vasomotor dysfunction. Methods and Results: In 35 patients CPT-induced alterations in epicardial luminal area were determined with quantitative angiography as the reference. MBF was assessed over the whole left ventricle as global MBF and regionally in the mid and mid-distal myocardium as MBF difference or MBF heterogeneity with nitrogen-13 ammonia and PET. The sensitivity and specificity of a longitudinal MBF difference during CPT in the identification of epicardial vasomotor dysfunction were significantly higher, than the global ΔMBF to CPT (88% vs 79% and 82% vs 64%, respectively; P<.05). Combining both parameters resulted in an optimal sensitivity of 100% at the expense of an intermediate specificity of 73%. The diagnostic accuracy was higher for the combined analysis than that for the MBF difference alone and global ΔMBF alone (91% vs 86% and 74%, respectively; P<.05). Conclusions: The combined evaluation of a CPT-induced heterogeneity in longitudinal MBF and the change in global MBF from rest may emerge as a new promising analytic approach to further optimize the identification and characterization of coronary vasomotor dysfunctio

    Characterization of a double-sided silicon strip detector autoradiography system

    Get PDF
    The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim of this study is to characterize the imaging performance of one such instrument, a double-sided silicon strip detector (DSSD) system for digital autoradiography. A novel aspect of this work is that the instrument, in contrast to previous prototype systems using the same detector type, provides the ability for user accessible imaging with higher throughput. Studies were performed to compare its spatial resolution to that of storage phosphor screens and test the implementation of multiradionuclide ex vivo imaging in a mouse preclinical animal study

    Molecular imaging in oncology: the acceptance of PET/CT and the emergence of MR/PET imaging

    Get PDF
    In the last decade, PET-only systems have been phased out and replaced with PET-CT systems. This merger of a functional and anatomical imaging modality turned out to be extremely useful in clinical practice. Currently, PET-CT is a major diagnostic tool in oncology. At the dawn of the merger of MRI and PET, another breakthrough in clinical imaging is expected. The combination of these imaging modalities is challenging, but has particular features such as imaging biological processes at the same time in specific body locations
    corecore