167 research outputs found

    Preliminary Report of NRC Twin Otter Operations in the 1997 Southern Great Plains Experiment

    Get PDF
    From June 18 to July 17, 1997, the NRC Twin Otter atmospheric research aircraft was operated from Oklahoma City, U.S.A., in the Southern Great Plains 1997 (SGP97) Hydrology Experiment. The primary role of the aircraft was to measure the vertical fluxes of sensible and latent heat, CO2, ozone and momentum in the atmospheric boundary layer, along with supporting meteorological and radiometric data. Approximately 400 flux runs and 100 soundings were flown in 27 project flights over rural areas near Oklahoma City. This preliminary report documents the flight program, lists the instrumentation aboard the aircraft, and presents a summary of run-averaged data from each flux run. These data are from the in-field analysis and must be considered preliminary. A re-analysis incorporating updated calibrations is planned for the fall of 1997 followed by a more comprehensive technical report

    A comparison of surface sensible and latent heat fluxes from aircraft and surface measurements in FIFE 1987

    Get PDF
    Surface fluxes of sensible and latent heat over a tall-grass prairie in central Kansas, as measured by 22 surface stations during FIFE 1987, are compared with values gained indirectly by linear extrapolation of aircraft-measured flux profiles to the surface. The results of 33 such comparisons covering the period 26 June to 13 October 1987 indicate that the sensible heat flux profiles were generally more linear with less scatter in the measurements at each level than were the latent heat flux profiles, the profile extrapolations of sensible heat flux in general underestimate the surface averages by about 30 percent, with slightly better agreement during periods of small flux, and the profile extrapolations of latent heat flux in general underestimate the surface averages by about 15 percent, with overestimates during periods of small fluxes (dry conditions) and overestimates during periods of large fluxes (moist conditions). Possible origins of the differences between the two sets of measurements are discussed, as directions for further research

    Superconducting fault current limiter application in a power-dense marine electrical system

    Get PDF
    Power-dense, low-voltage marine electrical systems have the potential for extremely high fault currents. Superconducting fault current limiters (SFCLs) have been of interest for many years and offer an effective method for reducing fault currents. This is very attractive in a marine vessel in terms of the benefits arising from reductions in switchgear rating (and consequently size, weight and cost) and damage at the point of fault. However, there are a number of issues that must be considered prior to installation of any SFCL device(s), particularly in the context of marine applications. Accordingly, this study analyses several such issues, including: location and resistance sizing of SFCLs; the potential effects of an SFCL on system voltage, power and frequency; and practical application issues such as the potential impact of transients such as transformer inrush. Simulations based upon an actual vessel are used to illustrate discussions and support assertions. It is shown that SFCLs, even with relatively small impedances, are highly effective at reducing prospective fault currents; the impact that higher resistance values has on fault current reduction and maintaining the system voltage for other non-faulted elements of the system is also presented and it is shown that higher resistance values are desirable in many cases. It is demonstrated that the exact nature of the SFCL application will depend significantly on the vessel’s electrical topology, the fault current contribution of each of the generators, and the properties of the SFCL device, such as size, weight, critical current value and recovery time

    Differential birefringence in Bragg gratings in multicore fiber under transverse stress

    Get PDF
    We present experimental measurements of the peak splitting of the reflection spectra of fiber Bragg gratings as a result of birefringence induced by transverse loading of a multicore fiber. Measurements show that the splitting is a function of the applied load and the direction of the load relative to the azimuth of the fiber. A model for calculating the stress in the fiber that is due to an applied load is in good agreement with our experimental observations

    Dynamic two-axis curvature measurement using multicore fiber Bragg gratings interrogated by arrayed waveguide gratings

    Get PDF
    We describe the use of arrayed waveguide gratings (AWGs) in the interrogation of fiber Bragg gratings (FBGs) for dynamic strain measurement. The ratiometric AWG output was calibrated in a static deflection experiment over a ±200 με range. Dynamic strain measurement was demonstrated with a FBG in a conventional single-mode fiber mounted on the surface of a vibrating cantilever and on a piezoelectric actuator, giving a resolution of 0.5 με at 2.4 kHz. We present results of this technique extended to measure the dynamic differential strain between two FBG pairs within a multicore fiber. An arbitrary cantilever oscillation of the multicore fiber was determined from curvature measurements in two orthogonal axes at 1125 Hz with a resolution of 0.05 m-1. © 2006 Optical Society of America

    Evolution of oxygen isotopic composition in the inner solar nebula

    Full text link
    Changes in the chemical and isotopic composition of the solar nebula with time are reflected in the properties of different constituents that are preserved in chondritic meteorites. CR carbonaceous chondrites are among the most primitive of all chondrite types and must have preserved solar nebula records largely unchanged. We have analyzed the oxygen and magnesium isotopes in a range of the CR constituents of different formation temperatures and ages, including refractory inclusions and chondrules of various types. The results provide new constraints on the time variation of the oxygen isotopic composition of the inner (<5 AU) solar nebula - the region where refractory inclusions and chondrules most likely formed. A chronology based on the decay of short-lived 26Al (t1/2 ~ 0.73 Ma) indicates that the inner solar nebula gas was 16O-rich when refractory inclusions formed, but less than 0.8 Ma later, gas in the inner solar nebula became 16O-poor and this state persisted at least until CR chondrules formed ~1-2 Myr later. We suggest that the inner solar nebula became 16O-poor because meter-size icy bodies, which were enriched in 17,18O due to isotopic self-shielding during the ultraviolet photo dissociation of CO in the protosolar molecular cloud or protoplanetary disk, agglomerated outside the snowline, drifted rapidly towards the Sun, and evaporated at the snowline. This led to significant enrichment in 16O-depleted water, which then spread through the inner solar system. Astronomical studies of the spatial and/or temporal variations of water abundance in protoplanetary disks may clarify these processes.Comment: 27 pages, 5 figure

    Acupuncture, Counseling, and Usual care for Depression (ACUDep): study protocol for a randomized controlled trial

    Get PDF
    Background: The evidence on the effect of acupuncture or counseling for depression is not conclusive yet is sufficient to warrant further research. Our aim is to conduct a full-scale RCT to determine the clinical and cost effectiveness of acupuncture and counseling compared to usual care alone. We will explore the experiences and perspectives of patients and practitioners. Methods/Design: Randomized controlled trial with three parallel arms: acupuncture plus usual care, counseling plus usual care, and usual care alone, in conjunction with a nested qualitative study using in-depth interviews with purposive samples of trial participants. Participants: Patients aged over 18 years diagnosed with depression or mood disorder by their GP and with a score of 20 or above on the Beck Depression Inventory (BDI-II). Randomization: Computer randomization by York Trials Unit to acupuncture, counseling, and usual care alone in proportions of 2:2:1, respectively, with secure allocation concealment. Interventions: Patients allocated to acupuncture and counseling groups receive the offer of up to 12 weekly sessions. Both interventions allow flexibility to address patient variation, yet are constrained within defined protocols. Acupuncture is based on traditional Chinese medicine and counseling is non-directive within the humanistic tradition. Outcome: The PHQ-9 is the primary outcome measure, collected at baseline, 3, 6, 9, and 12 months. Also measured is BDI-II, SF-36 Bodily pain subscale, and EQ-5D. Texted mood scores are collected weekly over the first 15 weeks. Health-related resource use is collected over 12 months. Analysis: The sample size target was for 640 participants, calculated for an effect size of 0.32 on the PHQ-9 when comparing acupuncture with counseling given 90% power, 5% significance, and 20% loss to follow-up. Analysis of covariance will be used on an intention-to-treat basis. Thematic analysis will be used for qualitative data. We will compare incremental cost-effectiveness of the three treatment options at 12 months. Discussion: Ethical approval was obtained in October 2009. There were six subsequent protocol amendments, the last of which was approved in January 2012. Recruitment of 755 participants took place over 18 months. Data collection will be completed by June 2012. No interim analyses have been conducted

    Safety of lumbar puncture in comatose children with clinical features of cerebral malaria

    Get PDF
    Objective: We assessed the independent association of lumbar puncture (LP) and death in Malawian children admitted to the hospital with the clinical features of cerebral malaria (CM). Methods: This was a retrospective cohort study in Malawian children with clinical features of CM. Allocation to LP was nonrandom and was associated with severity of illness. Propensity score-based analyses were used to adjust for this bias and assess the independent association between LP and mortality. Results: Data were available for 1,075 children: 866 (80.6%) underwent LP and 209 (19.4%) did not. Unadjusted mortality rates were lower in children who underwent LP (15.3% vs 26.7% in the no-LP group) but differences in covariates between the 2 groups suggested bias in LP allocation. After propensity score matching, all covariates were balanced. Propensity score-based analyses showed no change in mortality rate associated with LP: by inverse probability weighting, the average risk reduction was 2.0% at 12 hours (95% confidence interval -1.5% to 5.5%, p = 0.27) and 1.7% during hospital admission (95% confidence interval -4.5% to 7.9%, p = 0.60). Undergoing LP did not change the risk of mortality in subanalyses of children with severe brain swelling on MRI or in those with papilledema. Conclusion: In comatose children with suspected CM who were clinically stable, we found no evidence that LP increases mortality, even in children with objective signs of raised intracranial pressur
    corecore