174 research outputs found

    Bone densitometry in the evaluation of the results obtained with the use of bovine BMP in spine arthrodesis in rabbits

    Get PDF
    The object of this study is to evaluate the use of the bone densitometry as an evaluation method of the bone increment observed when we used bovine BMP in intertransverse arthrodesis of the rabbits' lumbar spine. Since the discovery of the BMP bone inductive properties, countless experimental models have been proposed. This caused the need of setting up evaluation methods to make possible a better understanding of the found results. Twenty female rabbits from New Zealand, divided in two groups, were submitted to the intertransverse arthrodesis of the lumbar column, segment L5/L6, posterior side. In the first group it was used autologous graft and in the second an association of autologous graft with biocompound (bovine BMP, 1.0 mg and hydroxyapatite, 9.0 mg). The animals were maintained in captivity, isolated and after 15 weeks submitted to the execution of bone densitometry by computerized tomography. 268 bone density measures of the normal bone, 134 measures of the newly formed bone by the association of the isolated autologous graft and 134 measures of the newly formed bone by the association autologous graft and BMP were obtained, what demonstrated a significant bone increment after statistical analysis (p=0.034) of the BMP/HAP group, when compared to the control group. We found this same variation of bone density analyzing the normal bone. The bone densitometry accomplished by the computerized tomography is an alternative method to assess the results when the BMP is used in experimental studies. Further studies should be accomplished for better understanding of the bone density variation found when the measures of the normal bone in the two groups are compared.As BMPs, proteínas indutoras de crescimento ósseo, desde o início de sua utilização, têm sido avaliadas em diferentes modelos experimentais objetivando determinar sua eficácia, sendo necessário o estabelecimento de métodos de avaliação que permitam melhor compreensão dos resultados. OBJETIVO: Este estudo tem por objetivo avaliar a utilização da densitometria óssea como método de avaliação do incremento ósseo observado quando da utilização de BMP bovina em artrodeses intertransversas da coluna lombar de coelhos. MÉTODOS: Foram utilizados dois grupos de dez coelhos neozelandeses fêmeas, submetidos a artrodese intertransversa da coluna lombar, segmento L5/L6, por via posterior. No primeiro grupo foi utilizado enxerto homólogo e no segundo a associação de enxerto homólogo com biocomposto (BMP bovino, 1,0 mg e hidroxiapatita, 9,0 mg). Os animais foram acompanhados por 15 semanas, isolados em cativeiro e avaliados diariamente por veterinário sob o ponto de vista clínico e neurológico e, posteriormente, submetidos à realização de densitometria óssea por tomografia computadorizada. RESULTADOS: Foram obtidas 268 medidas de densidade óssea do osso normal, 134 medidas do osso neoformado de enxerto homólogo isolado e 134 medidas do osso neoformado pela associação enxerto homólogo e BMP. Esses valores foram submetidos à análise estatística que demonstrou incremento ósseo significativo (p=0,034) do grupo BMP/HAP, quando comparado ao grupo controle. Os valores de densidade óssea do osso normal foram submetidos à mesma análise estatística onde se encontrou resultado semelhante. CONCLUSÃO: A densitometria óssea realizada pela tomografia computadorizada apresenta-se como método alternativo para avaliação de resultados quando utilizado BMP em estudos experimentais. Estudos subseqüentes deverão ser realizados para melhor entendimento da variação de densidade óssea encontrada quando da comparação das medidas do osso normal nos dois grupos.Universidade Federal de São Paulo (UNIFESP)Universidade Federal de São Paulo (UNIFESP) Departamento de Ortopedia e TraumatologiaUniversidade de São Paulo Faculdade de Odontologia de BauruUniversidade São Francisco Serviço de Ortopedia e TraumatologiaUNIFESP, Depto. de Ortopedia e TraumatologiaSciEL

    ANALYSIS OF THE SHOTS TO GOAL STRATEGIES OF FIRST DIVISION BRAZILIAN PROFESSIONAL SOCCER TEAMS

    Get PDF
    The purpose of this study was to analyze the shots to goal strategies during four soccer matches, through computational tracking. Software Dvideow was used to obtain data about players’ position and their technical actions and data treatment was performed in Matlab® environment. The results showed that the teams usually win the ball possession in their defensive soccer field and ball possessions that resulted in shot to goal can involve few or great number of passes depending on the game situation. Results do not corroborate with literature studies due to different methods of data treatment. Information about to these shots to goal strategies can help coaches to improve technical training, to find possible team mistakes and present it to players

    ANÁLISE DA VIABILIDADE ECONÔMICA DA AGÊNCIA DE INOVAÇÃO DE UMA INSTITUIÇÃO DE ENSINO SUPERIOR

    Get PDF
    Esta pesquisa apresenta uma análise econômica financeira da Agência de Inovação e Transferência de Tecnologia (AGITTEC) de uma Instituição de Ensino Superior (IES). Com a pretensão de contribuir para o conhecimento científico da área, este artigo foi construído tendo um problema de pesquisa definido emverificar quanto a AGITTEC necessita gerar de receita para que possa ser autofinanciada. Foi sistematizado um protocolo de pesquisa de acordo com o método sistemas dinâmicos condizente com o rigor metodológico exigido. A contribuição desta pesquisa se vincula a realizar uma discussão dos resultados favoráveis e benefícios da relação entre a universidade e agência, que podem se estender para melhoria da competitividade das empresas ao apresentarem um melhor desenvolvimento.O estudo serviu para verificar a que apesar das receitas, existe uma grande dependência da agência em relação aos recursos da IES, sendo cerca de 90% dos seus custos e despesas

    Statement of Second Brazilian Congress of Mechanical Ventilarion : part I

    Get PDF
    Resumo não disponíve

    Combined fit to the spectrum and composition data measured by the Pierre Auger Observatory including magnetic horizon effects

    Get PDF
    The measurements by the Pierre Auger Observatory of the energy spectrum and mass composition of cosmic rays can be interpreted assuming the presence of two extragalactic source populations, one dominating the flux at energies above a few EeV and the other below. To fit the data ignoring magnetic field effects, the high-energy population needs to accelerate a mixture of nuclei with very hard spectra, at odds with the approximate E2^{-2} shape expected from diffusive shock acceleration. The presence of turbulent extragalactic magnetic fields in the region between the closest sources and the Earth can significantly modify the observed CR spectrum with respect to that emitted by the sources, reducing the flux of low-rigidity particles that reach the Earth. We here take into account this magnetic horizon effect in the combined fit of the spectrum and shower depth distributions, exploring the possibility that a spectrum for the high-energy population sources with a shape closer to E2^{-2} be able to explain the observations

    Studies of the mass composition of cosmic rays and proton-proton interaction cross-sections at ultra-high energies with the Pierre Auger Observatory

    Get PDF
    In this work, we present an estimate of the cosmic-ray mass composition from the distributions of the depth of the shower maximum (Xmax) measured by the fluorescence detector of the Pierre Auger Observatory. We discuss the sensitivity of the mass composition measurements to the uncertainties in the properties of the hadronic interactions, particularly in the predictions of the particle interaction cross-sections. For this purpose, we adjust the fractions of cosmic-ray mass groups to fit the data with Xmax distributions from air shower simulations. We modify the proton-proton cross-sections at ultra-high energies, and the corresponding air shower simulations with rescaled nucleus-air cross-sections are obtained via Glauber theory. We compare the energy-dependent composition of ultra-high-energy cosmic rays obtained for the different extrapolations of the proton-proton cross-sections from low-energy accelerator data

    Study of downward Terrestrial Gamma-ray Flashes with the surface detector of the Pierre Auger Observatory

    Get PDF
    The surface detector (SD) of the Pierre Auger Observatory, consisting of 1660 water-Cherenkov detectors (WCDs), covers 3000 km2 in the Argentinian pampa. Thanks to the high efficiency of WCDs in detecting gamma rays, it represents a unique instrument for studying downward Terrestrial Gamma-ray Flashes (TGFs) over a large area. Peculiar events, likely related to downward TGFs, were detected at the Auger Observatory. Their experimental signature and time evolution are very different from those of a shower produced by an ultrahigh-energy cosmic ray. They happen in coincidence with low thunderclouds and lightning, and their large deposited energy at the ground is compatible with that of a standard downward TGF with the source a few kilometers above the ground. A new trigger algorithm to increase the TGF-like event statistics was installed in the whole array. The study of the performance of the new trigger system during the lightning season is ongoing and will provide a handle to develop improved algorithms to implement in the Auger upgraded electronic boards. The available data sample, even if small, can give important clues about the TGF production models, in particular, the shape of WCD signals. Moreover, the SD allows us to observe more than one point in the TGF beam, providing information on the emission angle

    Measuring the muon content of inclined air showers using AERA and the water-Cherenkov detector array of the Pierre Auger Observatory

    Get PDF

    The dynamic range of the upgraded surface-detector stations of AugerPrime

    Get PDF
    The detection of ultra-high-energy cosmic rays by means of giant detector arrays is often limited by the saturation of the recorded signals near the impact point of the shower core at the ground, where the particle density dramatically increases. The saturation affects in particular the highest energy events, worsening the systematic uncertainties in the reconstruction of the shower characteristics. The upgrade of the Pierre Auger Observatory, called AugerPrime, includes the installation of an 1-inch Small PhotoMultiplier Tube (SPMT) inside each water-Cherenkov station (WCD) of the surface detector array. The SPMT allows an unambiguous measurement of signals down to about 250m from the shower core, thus reducing the number of events featuring a saturated station to a negligible level. In addition, a 3.8m2 plastic scintillator (Scintillator Surface Detector, SSD) is installed on top of each WCD. The SSD is designed to match the WCD (with SPMT) dynamic range, providing a complementary measurement of the shower components up to the highest energies. In this work, the design and performances of the upgraded AugerPrime surface-detector stations in the extended dynamic range are described, highlighting the accuracy of the measurements. A first analysis employing the unsaturated signals in the event reconstruction is also presented

    The second knee in the cosmic ray spectrum observed with the surface detector of the Pierre Auger Observatory

    Get PDF
    corecore