55 research outputs found

    Small wind energy systems. State of the art and new challenges

    Get PDF
    This paper is devoted to the analysis of small wind energy systems, including a review of the state of the art and new challenges

    Stream data cleaning for dynamic line rating application

    Get PDF
    The maximum current that an overhead transmission line can continuously carry depends on external weather conditions, most commonly obtained from real-time streaming weather sensors. The accuracy of the sensor data is very important in order to avoid problems such as overheating. Furthermore, faulty sensor readings may cause operators to limit or even stop the energy production from renewable sources in radial networks. This paper presents a method for detecting and replacing sequences of consecutive faulty data originating from streaming weather sensors. The method is based on a combination of (a) a set of constraints obtained from derivatives in consecutive data, and (b) association rules that are automatically generated from historical data. In smart grids, a large amount of historical data from different weather stations are available but rarely used. In this work, we show that mining and analyzing this historical data provides valuable information that can be used for detecting and replacing faulty sensor readings. We compare the result of the proposed method against the exponentially weighted moving average and vector autoregression models. Experiments on data sets with real and synthetic errors demonstrate the good performance of the proposed method for monitoring weather sensors.This research was partially funded by Spanish Government under Spanish R+D initiative with reference ENE2013-42720-R and RETOS RTC-2015-3795-3

    Influence on power quality measurement of the simultaneous presence of different disturbances

    Get PDF
    Power Quality measurements involve not only problems related with the real use of recorders but also theoretical questions connected with functional and design aspects of the instrumentation. In addition, there are a rising number of standards covering topics from design to data analysis, so final users usually assume that they do not have to pay special attention to PQ instrumentation functionality when the device is designed according to approved standards. However, it is not unusual to find different disturbances at the same point and in the same time and standards do not say anything about their mutual influence on PQ index. The main aim of this research work is to show the influence that having different disturbances (flicker and sags) simultaneously has on the final results provided by the instrumentation for each individual disturbance. The paper proposes a test system and a methodology. The results of various tests using commercial and research instrumentation are presented and some possible solutions to these problems are considered

    Alarma activada por control remoto selectivo.

    Get PDF
    La finalidad de esta invención consiste en disponer de una alarma que bien evite el robo de objetos ligeros y portátiles por el procedimiento que se conoce como "del tirón" --es decir, arrebatar algo y salir corriendo--, bien permita identificar un equipaje entre otros. La originalidad del dispositivo reside en la activación/desactivación del dispositivo de sonido por control remoto, así como la posibilidad de seleccionar el sonido de salida dependiendo de su finalidad. Se reivindica como de nueva y propia invención la propiedad y explotación de cualquier alarma caracterizada por la inclusión en su circuito eléctrico o electrónico del dispositivo que se ha llamado control remoto selectivo, capaz de activar/desactivar la alarma y/o emitir dos sonidos funcionalmente distintos. Puede instalarse en bolsos, portafolios, neceseres, ordenadores, radio-casettes y, en general, objetos ligeros o portátiles, que frecuentemente, son robados en la calle o establecimientos públicos; o en cualquier objeto a identificar entre un conjunto de equipajes.Solicitud: 9502265 (06.11.1995)Nº Pub. de Solicitud: ES2112778A1 (01.04.1998)Nº de Patente: ES2112778B1 (16.12.1998

    A methodology for the calculation of typical gas concentration values and sampling intervals in the power transformers of a distribution system operator†

    Get PDF
    Predictive maintenance strategies in power transformers aim to assess the risk through the calculation and monitoring of the health index of the power transformers. The parameter most used in predictive maintenance and to calculate the health index of power transformers is the dissolved gas analysis (DGA). The current tendency is the use of online DGA monitoring equipment while continuing to perform analyses in the laboratory. Although the DGA is well known, there is a lack of published experimental data beyond that in the guides. This study used the nearest-rank method for obtaining the typical gas concentration values and the typical rates of gas increase from a transformer population to establish the optimal sampling interval and alarm thresholds of the continuous monitoring devices for each power transformer. The percentiles calculated by the nearest-rank method were within the ranges of the percentiles obtained using the R software, so this simple method was validated for this study. The results obtained show that the calculated concentration limits are within the range of or very close to those proposed in IEEE C57.104-2019 and IEC 60599:2015. The sampling intervals calculated for each transformer were not correct in all cases since the trend of the historical DGA samples modified the severity of the calculated intervals.This work was partially financed by the EU Regional Development Fund (FEDER) and the Spanish Government under RETOS-COLABORACIÓN RTC-2017-6782-3 and by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 864579 (FLEXIGRID)

    Determination of transformer oil contamination from the OLTC gases in the power transformers of a distribution system operator

    Get PDF
    Power transformers are considered to be the most important assets in power substations. Thus, their maintenance is important to ensure the reliability of the power transmission and distribution system. One of the most commonly used methods for managing the maintenance and establishing the health status of power transformers is dissolved gas analysis (DGA). The presence of acetylene in the DGA results may indicate arcing or high-temperature thermal faults in the transformer. In old transformers with an on-load tap-changer (OLTC), oil or gases can be filtered from the OLTC compartment to the transformer?s main tank. This paper presents a method for determining the transformer oil contamination from the OLTC gases in a group of power transformers for a distribution system operator (DSO) based on the application of the guides and the knowledge of experts. As a result, twenty-six out of the 175 transformers studied are defined as contaminated from the OLTC gases. In addition, this paper presents a methodology based on machine learning techniques that allows the system to determine the transformer oil contamination from the DGA results. The trained model achieves an accuracy of 99.76% in identifying oil contamination.This work was partially financed by the EU Regional Development Fund (FEDER) and the Spanish Government under RETOS-COLABORACIÓN RTC-2017-6782-3 and by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 864579 (FLEXIGRID)

    A comparison of mechanical and ultrasonic anemometers for ampacity thermal rating in overhead lines

    Get PDF
    CIGRE TB601 guide for thermal rating calculations recommends the use of ultrasonic anemometers over mechanical devices [1]. This paper aims to compare the mechanical and ultrasonic wind speed measurement technologies for the purpose of dynamic ampacity rating. The comparison consists of applying the measurements of both anemometers (placed in the same spot) to the computation of ampacity in the same overhead line, and evaluating the diferences at different speed ranges.This work was supported by the Spanish Government under the R+D initiative INNPACTO with reference IPT- 2011-1447-920000 and Spanish R+D initiative with reference ENE2013-42720-R. The authors of this article would also like to acknowledge Viesgo for its continuous support to the dynamic ampacity rating line of investigation

    Energy meter behaviour under non-sinusoidal conditions

    Get PDF
    Currently, there are two energy meters types installed: electromechanicals and electronics. The first ones are still the most frequent. However, new facilities tend to use electronics energy meters based on solid-state technology. Electromechanicals devices present characteristics already well known that allows us to measure only energy consumption. However, now the rules that manage the energy supply are totally new, there is a competitive electricity market. This way, detailed information on the energy consumption of each client is needed. In this point, electronic meters seem to be the best option to face the new challenges. This study will review the operating principles of solid-state energy meters. The behavior of some three phases models under nonsinusoidal conditions is studied. Experimental setup and test methodology are discussed as well

    Comparative study of techniques used in the generation expansion planning

    Get PDF
    At the present time the generation expansion planning (GEP) has become a problem very difficult to solve for multiple reasons: many objectives, high uncertainties, very great planning horizon, etc. Its resolution by means of the exact traditional techniques, in numerous occasions, is not viable by the excessive time that is needed. For that reason, technical modern that allow the resolution in smaller time and with smaller accuracy in the solution are applied. Most of the approximate techniques are included inside a wider concept that is denominated Artificial Intelligence. In this article the more promising techniques of IA are studied indicating their applications in the PEG as well as their advantages and disadvantages
    corecore