181 research outputs found

    DNA Suspension Arrays: Silencing Discrete Artifacts for High-Sensitivity Applications

    Get PDF
    Detection of low frequency single nucleotide polymorphisms (SNPs) has important implications in early screening for tumorgenesis, genetic disorders and pathogen drug resistance. Nucleic acid arrays are a powerful tool for genome-scale SNP analysis, but detection of low-frequency SNPs in a mixed population on an array is problematic. We demonstrate a model assay for HIV-1 drug resistance mutations, wherein ligase discrimination products are collected on a suspension array. In developing this system, we discovered that signal from multiple polymorphisms was obscured by two discrete hybridization artifacts. Specifically: 1) tethering of unligated probes on the template DNA elicited false signal and 2) unpredictable probe secondary structures impaired probe capture and suppressed legitimate signal from the array. Two sets of oligonucleotides were used to disrupt these structures; one to displace unligated reporter labels from the bead-bound species and another to occupy sequences which interfered with array hybridization. This artifact silencing system resulted in a mean 21-fold increased sensitivity for 29 minority variants of 17 codons in our model assay for mutations most commonly associated with HIV-1 drug resistance. Furthermore, since the artifacts we characterized are not unique to our system, their specific inhibition might improve the quality of data from solid-state microarrays as well as from the growing number of multiple analyte suspension arrays relying on sequence-specific nucleic acid target capture

    Development and Evaluation of a New Lateral Flow Immunoassay for Serodiagnosis of Human Fasciolosis

    Get PDF
    Fasciolosis is an important plant-borne trematode zoonosis. This disease is of both clinical and veterinary relevance and, according to the WHO, is considered a re-emerging disease that is spreading around the world. Fasciolosis has a serious impact on health because of the large size of the parasite and the effects of the parasite in down-regulating the host immune response. Human fasciolosis can be distinguished by an acute phase, in which the parasite migrates through different tissues, and a chronic phase in which it invades the bile ducts. Here we describe the development of a rapid, simple and inexpensive immunochromatographic diagnostic method, based on the use of a recombinant cathepsin L1 protein, which performs better than other more complex indirect methods, providing similar specificity and higher sensitivity. The simplicity of the method represents a great advantage for the intervention systems applied in different endemic areas by WHO, such as passive case finding (e.g. Vietnam) and selective treatment (e.g. Egypt). Because of its characteristics, the system can be applied to both phases of the disease, and in holo, meso and hyperendemic areas where point-of-care testing is required

    A Computational Study on the Role of Gap Junctions and Rod Ih Conductance in the Enhancement of the Dynamic Range of the Retina

    Get PDF
    Recent works suggest that one of the roles of gap junctions in sensory systems is to enhance their dynamic range by avoiding early saturation in the first processing stages. In this work, we use a minimal conductance-based model of the ON rod pathways in the vertebrate retina to study the effects of electrical synaptic coupling via gap junctions among rods and among AII amacrine cells on the dynamic range of the retina. The model is also used to study the effects of the maximum conductance of rod hyperpolarization activated current Ih on the dynamic range of the retina, allowing a study of the interrelations between this intrinsic membrane parameter with those two retina connectivity characteristics. Our results show that for realistic values of Ih conductance the dynamic range is enhanced by rod-rod coupling, and that AII-AII coupling is less relevant to dynamic range amplification in comparison with receptor coupling. Furthermore, a plot of the retina output response versus input intensity for the optimal parameter configuration is well fitted by a power law with exponent . The results are consistent with predictions of more theoretical works and suggest that the earliest expression of gap junctions along the rod pathways, together with appropriate values of rod Ih conductance, has the highest impact on vertebrate retina dynamic range enhancement

    A retrospective population-based study of childhood hospital admissions with record linkage to a birth defects registry

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Using population-based linked records of births, deaths, birth defects and hospital admissions for children born 1980–1999 enables profiles of hospital morbidity to be created for each child.</p> <p>Methods</p> <p>This is an analysis of a state-based registry of birth defects linked to population-based hospital admission data. Transfers and readmissions within one day could be taken into account and treated as one episode of care for the purposes of analyses (N = 485,446 children; 742,845 non-birth admissions).</p> <p>Results</p> <p>Children born in Western Australia from 1980–1999 with a major birth defect comprised 4.6% of live births but 12.0% of non-birth hospital admissions from 1980–2000. On average, the children with a major birth defect remained in hospital longer than the children in the comparison group for the same diagnosis. The mean and median lengths of stay (LOS) for admissions before the age of 5 years have decreased for all children since 1980. However, the mean number of admissions per child admitted has remained constant at around 3.8 admissions for children with a major birth defect and 2.2 admissions for all other children.</p> <p>Conclusion</p> <p>To gain a true picture of the burden of hospital-based morbidity in childhood, admission records need to be linked for each child. We have been able to do this at a population level using birth defect cases ascertained by a birth defects registry. Our results showed a greater mean LOS and mean number of admissions per child admitted than previous studies. The results suggest there may be an opportunity for the children with a major birth defect to be monitored and seen earlier in the primary care setting for common childhood illnesses to avoid hospitalisation or reduce the LOS.</p

    D-shaped configurations in FTU for testing liquid lithium limiter: Preliminary studies and experiments

    Get PDF
    The feasibility of getting "D" shaped plasma configurations in FTU, with a possible X point close to the first wall, has been investigated with the aim of achieving an H-mode regime in this machine. This regime could allow both evaluating the thermal effects on the liquid lithium limiter due to the possible Edge Localized Modes and studying the L-H transition properties in low recycling conditions due to the presence of lithium.. An alternative design for the magnetic system in FTU has been also proposed, to realize an X-point inside the plasma chamber, close to the Liquid Lithium Limiter.Preliminary experiments with elongated configurations and limited ECRH additional heating power did not allowed approaching the L-H transition but they were used to develop a proper elongation control. This controller allowed guaranteeing the vertical stability in elongated configurations despite the reduced power available for the horizontal field coils in FTU. The elongation was stably keep over 1.2, while the lithium limiter was very close to the last close flux surface. Neither limiter damages nor plasma pollution were observed in these configurations.A possible alternative connection of the poloidal field coils in FTU is here proposed, with the aim of achieving a true X-point configuration with a magnetic single null well inside the plasma chamber and strike points on the lithium limiter. A preliminary assessment of this design allowed estimating the required power supply upgrade and showed its compatibility with the existing mechanical structure and cooling system, at least for plasmas with current up to 300 kA and flat-top duration up to 4s. Keywords: FTU, Liquid lithium limiter, L-H transition, X-point, Plasma elongatio

    The interpretation of systematic reviews with meta-analyses: an objective or subjective process?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Discrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective of this study was to determine the discordance in interpretations when meta-analysts are presented with identical data.</p> <p>Methods</p> <p>We searched the literature for all randomized clinical trials (RCT) and review articles on the efficacy of intravenous magnesium in the early post-myocardial infarction period. We organized the articles chronologically and grouped them in packages. The first package included the first RCT, and a summary of the review articles published prior to first RCT. The second package contained the second and third RCT, a meta-analysis based on the data, and a summary of all review articles published prior to the third RCT. Similar packages were created for the 5<sup>th </sup>RCT, 10<sup>th </sup>RCT, 20<sup>th </sup>RCT and 23<sup>rd </sup>RCT (all articles). We presented the packages one at a time to eight different reviewers and asked them to answer three clinical questions after each package based solely on the information provided. The clinical questions included whether 1) they believed magnesium is now proven beneficial, 2) they believed magnesium will eventually be proven to be beneficial, and 3) they would recommend its use at this time.</p> <p>Results</p> <p>There was considerable disagreement among the reviewers for each package, and for each question. The discrepancies increased when the heterogeneity of the data increased. In addition, some reviewers became more sceptical of the effectiveness of magnesium over time, and some reviewers became less sceptical.</p> <p>Conclusion</p> <p>The interpretation of the results of systematic reviews with meta-analyses includes a subjective component that can lead to discordant conclusions that are independent of the methodology used to obtain or analyse the data.</p

    NeuroML: A Language for Describing Data Driven Models of Neurons and Networks with a High Degree of Biological Detail

    Get PDF
    Biologically detailed single neuron and network models are important for understanding how ion channels, synapses and anatomical connectivity underlie the complex electrical behavior of the brain. While neuronal simulators such as NEURON, GENESIS, MOOSE, NEST, and PSICS facilitate the development of these data-driven neuronal models, the specialized languages they employ are generally not interoperable, limiting model accessibility and preventing reuse of model components and cross-simulator validation. To overcome these problems we have used an Open Source software approach to develop NeuroML, a neuronal model description language based on XML (Extensible Markup Language). This enables these detailed models and their components to be defined in a standalone form, allowing them to be used across multiple simulators and archived in a standardized format. Here we describe the structure of NeuroML and demonstrate its scope by converting into NeuroML models of a number of different voltage- and ligand-gated conductances, models of electrical coupling, synaptic transmission and short-term plasticity, together with morphologically detailed models of individual neurons. We have also used these NeuroML-based components to develop an highly detailed cortical network model. NeuroML-based model descriptions were validated by demonstrating similar model behavior across five independently developed simulators. Although our results confirm that simulations run on different simulators converge, they reveal limits to model interoperability, by showing that for some models convergence only occurs at high levels of spatial and temporal discretisation, when the computational overhead is high. Our development of NeuroML as a common description language for biophysically detailed neuronal and network models enables interoperability across multiple simulation environments, thereby improving model transparency, accessibility and reuse in computational neuroscience

    The location of the axon initial segment affects the bandwidth of spike initiation dynamics

    Get PDF
    The dynamics and the sharp onset of action potential (AP) generation have recently been the subject of intense experimental and theoretical investigations. According to the resistive coupling theory, an electrotonic interplay between the site of AP initiation in the axon and the somato-dendritic load determines the AP waveform. This phenomenon not only alters the shape of AP recorded at the soma, but also determines the dynamics of excitability across a variety of time scales. Supporting this statement, here we generalize a previous numerical study and extend it to the quantification of the input-output gain of the neuronal dynamical response. We consider three classes of multicompartmental mathematical models, ranging from ball-and-stick simplified descriptions of neuronal excitability to 3D-reconstructed biophysical models of excitatory neurons of rodent and human cortical tissue. For each model, we demonstrate that increasing the distance between the axonal site of AP initiation and the soma markedly increases the bandwidth of neuronal response properties. We finally consider the Liquid State Machine paradigm, exploring the impact of altering the site of AP initiation at the level of a neuronal population, and demonstrate that an optimal distance exists to boost the computational performance of the network in a simple classification task. Copyright

    Combination antiretroviral therapy and the risk of myocardial infarction

    Get PDF
    • …
    corecore