792 research outputs found

    A Novel Structural Assessment Technique to Prevent Damaged FRP-Wrapped Concrete Bridge Piers from Collapse

    Get PDF
    Repairing deteriorated concrete bridge piers using externally wrapped fiber reinforced polymer (FRP) composites have been proven as an effective approach. This technique has also been applied to low-rise building structures. Failures in FRP-wrapped concrete structures may occur by flexural failures of critical sections or by debonding of FRP plate from the concrete substrate. Debonding in the FRP/adhesive/concrete interface region may cause a significant decrease in member capacity leading to a premature failure of the system. In this chapter, a novel structural assessment technique aiming at inspecting the near-surface FRP debonding and concrete cracking of damaged FRP-wrapped concrete bridge piers to prevent the structures from collapse is presented. In the first part of this chapter, failure mechanisms of FRP-wrapped concrete systems are briefly discussed. The second part of this chapter introduces a novel structural assessment technique in which far-field airborne radar is applied. In this development, emphasis is placed on inspection of debonding in glass FRP (GFRP)-wrapped concrete cylinders, while the technique is also applicable to beams and slabs with bonded GFRP composites. Physical radar measurements on laboratory specimens with structural damages were conducted and used for validating the technique. Processed experimental measurements have shown promising results for the future application of the technique. Finally, research findings and issues are summarized.National Science Foundation (U.S.) (Grant CMS-0324607)Lincoln Laborator

    Avaliação da resistência ao cisalhamento da união entre duas ligas a base de CoCr e uma cerâmica

    Get PDF
    INTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). MATERIAL and METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer’s recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS and CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys. ______________________________________________________________________________________________________________ RESUMOINTRODUÇÃO: Baseados na importância da integridade da interface metal-cerâmica, este trabalho tem como objetivo avaliar a resistência ao cisalhamento da união metal-cerâmica de duas ligas de Co-Cr (Wirobond C, Bego; Remanium 2000, Dentaurum) combinadas com a cerâmica Omega 900 (Vita Zahnfabrik). MATERIAIS E MÉTODOS: Foram confeccionados 11 corpos-de-prova cilíndricos para cada liga utilizada, sendo que a porção metálica foi obtida por fundição pela técnica da cera perdida, através de enceramentos padronizados com 4mm de altura por 4mm de diâmetro. A aplicação da cerâmica foi realizada segundo recomendações do fabricante, com auxílio de uma matriz de teflon que permitia sua padronização com as mesmas dimensões da porção metálica. Os corpos-de-prova foram submetidos ao ensaio de resistência ao cisalhamento em máquina de ensaios universal (EMIC), com auxílio de dispositivo desenvolvido para tal propósito, sob velocidade constante de 0,5mm/ min. RESULTADOS E CONCLUSÕES: As médias de resistência obtidas foram 48,387 MPa para a liga Wirobond C, com desvio padrão de 17,718, e 55,956 MPa para a Remanium 2000, com desvio padrão de 17,198. Após análise de variância foi possível observar que não há diferença estatisticamente significante entre os valores de resistência ao cisalhamento das duas ligas metalocerâmicas

    The Pioneer Anomaly

    Get PDF
    Radio-metric Doppler tracking data received from the Pioneer 10 and 11 spacecraft from heliocentric distances of 20-70 AU has consistently indicated the presence of a small, anomalous, blue-shifted frequency drift uniformly changing with a rate of ~6 x 10^{-9} Hz/s. Ultimately, the drift was interpreted as a constant sunward deceleration of each particular spacecraft at the level of a_P = (8.74 +/- 1.33) x 10^{-10} m/s^2. This apparent violation of the Newton's gravitational inverse-square law has become known as the Pioneer anomaly; the nature of this anomaly remains unexplained. In this review, we summarize the current knowledge of the physical properties of the anomaly and the conditions that led to its detection and characterization. We review various mechanisms proposed to explain the anomaly and discuss the current state of efforts to determine its nature. A comprehensive new investigation of the anomalous behavior of the two Pioneers has begun recently. The new efforts rely on the much-extended set of radio-metric Doppler data for both spacecraft in conjunction with the newly available complete record of their telemetry files and a large archive of original project documentation. As the new study is yet to report its findings, this review provides the necessary background for the new results to appear in the near future. In particular, we provide a significant amount of information on the design, operations and behavior of the two Pioneers during their entire missions, including descriptions of various data formats and techniques used for their navigation and radio-science data analysis. As most of this information was recovered relatively recently, it was not used in the previous studies of the Pioneer anomaly, but it is critical for the new investigation.Comment: 165 pages, 40 figures, 16 tables; accepted for publication in Living Reviews in Relativit

    Proportions of CD4+ memory T cells are altered in individuals chronically infected with Schistosoma haematobium

    Get PDF
    Characterisation of protective helminth acquired immunity in humans or experimental models has focused on effector responses with little work conducted on memory responses. Here we show for the first time, that human helminth infection is associated with altered proportions of the CD4+ memory T cells, with an associated alteration of TH1 responses. The reduced CD4+ memory T cell proportions are associated with a significantly lower ratio of schistosome-specific IgE/IgG4 (marker for resistance to infection/re-infection) in uninfected older people. Helminth infection does not affect the CD8+ memory T cell pool. Furthermore, we show for the first time in a helminth infection that the CD4+ memory T cell proportions decline following curative anti-helminthic treatment despite increased CD4+ memory cell replication. Reduced accumulation of the CD4+ memory T cells in schistosome-infected people has implications for the development of natural or vaccine induced schistosome-specific protective immunity as well as for unrelated pathogens

    Development and Validation of a Surgical Workload Measure: The Surgery Task Load Index (SURG-TLX)

    Get PDF
    Background: The purpose of the present study was to develop and validate a multidimensional, surgery-specific workload measure (the SURG-TLX), and to determine its utility in providing diagnostic information about the impact of various sources of stress on the perceived demands of trained surgical operators. As a wide range of stressors have been identified for surgeons in the operating room, the current approach of considering stress as a unidimensional construct may not only limit the degree to which underlying mechanisms may be understood but also the degree to which training interventions may be successfully matched to particular sources of stress. Methods: The dimensions of the SURG-TLX were based on two current multidimensional workload measures and developed via focus group discussion. The six dimensions were defined as mental demands, physical demands, temporal demands, task complexity, situational stress, and distractions. Thirty novices were trained on the Fundamentals of Laparoscopic Surgery (FLS) peg transfer task and then completed the task under various conditions designed to manipulate the degree and source of stress experienced: task novelty, physical fatigue, time pressure, evaluation apprehension, multitasking, and distraction. Results: The results were supportive of the discriminant sensitivity of the SURG-TLX to different sources of stress. The sub-factors loaded on the relevant stressors as hypothesized, although the evaluation pressure manipulation was not strong enough to cause a significant rise in situational stress. Conclusions: The present study provides support for the validity of the SURG-TLX instrument and also highlights the importance of considering how different stressors may load surgeons. Implications for categorizing the difficulty of certain procedures, the implementation of new technology in the operating room (man-machine interface issues), and the targeting of stress training strategies to the sources of demand are discussed. Modifications to the scale to enhance clinical utility are also suggested. © 2011 The Author(s).published_or_final_versionSpringer Open Choice, 21 Feb 201

    Role of the CCAAT-Binding Protein NFY in SCA17 Pathogenesis

    Get PDF
    Spinocerebellar ataxia 17 (SCA17) is caused by expansion of the polyglutamine (polyQ) tract in human TATA-box binding protein (TBP) that is ubiquitously expressed in both central nervous system and peripheral tissues. The spectrum of SCA17 clinical presentation is broad. The precise pathogenic mechanism in SCA17 remains unclear. Previously proteomics study using a cellular model of SCA17 has revealed reduced expression of heat shock 70 kDa protein 5 (HSPA5) and heat shock 70 kDa protein 8 (HSPA8), suggesting that impaired protein folding may contribute to the cell dysfunction of SCA17 (Lee et al., 2009). In lymphoblastoid cells, HSPA5 and HSPA8 expression levels in cells with mutant TBP were also significantly lower than that of the control cells (Chen et al., 2010). As nuclear transcription factor Y (NFY) has been reported to regulate HSPA5 transcription, we focused on if NFY activity and HSPA5 expression in SCA17 cells are altered. Here, we show that TBP interacts with NFY subunit A (NFYA) in HEK-293 cells and NFYA incorporated into mutant TBP aggregates. In both HEK-293 and SH-SY5Y cells expressing TBP/Q61∼79, the level of soluble NFYA was significantly reduced. In vitro binding assay revealed that the interaction between TBP and NFYA is direct. HSPA5 luciferase reporter assay and endogenous HSPA5 expression analysis in NFYA cDNA and siRNA transfection cells further clarified the important role of NFYA in regulating HSPA5 transcription. In SCA17 cells, HSPA5 promoter activity was activated as a compensatory response before aggregate formation. NFYA dysfunction was indicated in SCA17 cells as HSPA5 promoter activity reduced along with TBP aggregate formation. Because essential roles of HSPA5 in protection from neuronal apoptosis have been shown in a mouse model, NFYA could be a target of mutant TBP in SCA17
    • …
    corecore