319 research outputs found
Electroencephalographic characteristics of epileptic seizures in preterm neonates
OBJECTIVE:
Although seizures are more common in the neonatal period than in any other stage of childhood, those in preterm neonates are still poorly described. The aim of this study was to assess electro-clinical characteristics of seizures occurring before a corrected age of 40 weeks in neonates born prematurely.
METHOD:
Retrospective analysis of EEG-documented seizures in neonates born prematurely. Seizures in a group of term neonates served as controls.
RESULTS:
Fifty-six prematurely born and 46 term born neonates were included. Median duration of seizures was 52 s in preterm and 96 s in term neonates. Seizures were focal or multifocal. In least mature neonates, they involved smaller regions of onset and remained localised. With increasing corrected age, propagation became more frequent. The electrographic pattern – maximal frequency of oscillation and the onset pattern also evolved with age. Electro-clinical seizures were observed in 25% of preterm versus 50% of term neonates; almost all electro-clinical seizures involved the central (motor) regions.
CONCLUSION:
Ictal EEG features undergo changes depending on corrected age. Most seizures are subclinical, thus EEG is essential for diagnosis.
SIGNIFICANCE:
Relating ictal EEG pattern to corrected age can improve diagnosis and ultimately management
MPGDs in Compton imaging with liquid-xenon
The interaction of radiation with liquid xenon, inducing both scintillation
and ionization signals, is of particular interest for Compton-sequences
reconstruction. We report on the development and recent results of a
liquid-xenon time-projection chamber, dedicated to a novel nuclear imaging
technique named "3 gamma imaging". In a first prototype, the scintillation is
detected by a vacuum photomultiplier tube and the charges are collected with a
MICROMEGAS structure; both are fully immersed in liquid xenon. In view of the
final large-area detector, and with the aim of minimizing dead-zones, we are
investigating a gaseous photomultiplier for recording the UV scintillation
photons. The prototype concept is presented as well as preliminary results in
liquid xenon. We also present soft x-rays test results of a gaseous
photomultiplier prototype made of a double Thick Gaseous Electron Multiplier
(THGEM) at normal temperature and pressure conditions.Comment: presented at MPGD09, CRETE, June 2009; to be published in JINST
Proceedings, PDF, 10 pages, 11 figure
Optimization of laser capture microdissection and RNA amplification for gene expression profiling of prostate cancer
BACKGROUND: To discover prostate cancer biomarkers, we profiled gene expression in benign and malignant cells laser capture microdissected (LCM) from prostate tissues and metastatic prostatic adenocarcinomas. Here we present methods developed, optimized, and validated to obtain high quality gene expression data. RESULTS: RNase inhibitor was included in solutions used to stain frozen tissue sections for LCM, which improved RNA quality significantly. Quantitative PCR assays, requiring minimal amounts of LCM RNA, were developed to determine RNA quality and concentration. SuperScript II™ reverse transcriptase was replaced with SuperScript III™, and SpeedVac concentration was eliminated to optimize linear amplification. The GeneChip(® )IVT labeling kit was used rather than the Enzo BioArray™ HighYield™ RNA transcript labeling kit since side-by-side comparisons indicated high-end signal saturation with the latter. We obtained 72 μg of labeled complementary RNA on average after linear amplification of about 2 ng of total RNA. CONCLUSION: Unsupervised clustering placed 5/5 normal and 2/2 benign prostatic hyperplasia cases in one group, 5/7 Gleason pattern 3 cases in another group, and the remaining 2/7 pattern 3 cases in a third group with 8/8 Gleason pattern 5 cases and 3/3 metastatic prostatic adenocarcinomas. Differential expression of alpha-methylacyl coenzyme A racemase (AMACR) and hepsin was confirmed using quantitative PCR
Sub MeV Particles Detection and Identification in the MUNU detector ((1)ISN, IN2P3/CNRS-UJF, Grenoble, France, (2)Institut de Physique, Neuch\^atel, Switzerland, (3) INFN, Padova Italy, (4) Physik-Institut, Z\"{u}rich, Switzerland)
We report on the performance of a 1 m TPC filled with CF at 3
bar, immersed in liquid scintillator and viewed by photomultipliers. Particle
detection, event identification and localization achieved by measuring both the
current signal and the scintillation light are presented. Particular features
of particle detection are also discussed. Finally, the Mn
photopeak, reconstructed from the Compton scattering and recoil angle is shown.Comment: Latex, 19 pages, 20 figure
Radio emission of extensive air shower at CODALEMA: Polarization of the radio emission along the v*B vector
Cosmic rays extensive air showers (EAS) are associated with transient radio
emission, which could provide an efficient new detection method of high energy
cosmic rays, combining a calorimetric measurement with a high duty cycle. The
CODALEMA experiment, installed at the Radio Observatory in Nancay, France, is
investigating this phenomenon in the 10^17 eV region. One challenging point is
the understanding of the radio emission mechanism. A first observation
indicating a linear relation between the electric field produced and the cross
product of the shower axis with the geomagnetic field direction has been
presented (B. Revenu, this conference). We will present here other strong
evidences for this linear relationship, and some hints on its physical origin.Comment: Contribution to the 31st International Cosmic Ray Conference, Lodz,
Poland, July 2009. 4 pages, 8 figures. v2: Typo fixed, arxiv references adde
Limits on the neutrino magnetic moment from the MUNU experiment
The MUNU experiment was carried out at the Bugey nuclear power reactor. The
aim was the study of electron antineutrino-electron elastic scattering at low
energy. The recoil electrons were recorded in a gas time projection chamber,
immersed in a tank filled with liquid scintillator serving as veto detector,
suppressing in particular Compton electrons. The measured electron recoil
spectrum is presented. Upper limits on the neutrino magnetic moment were
derived and are discussed.Comment: 9 pages, 7 figures Added reference: p.3, 1st col., TEXONO Added
sentence: p.4, 1st col., electron attachement Modified sentence: p.5, 1st
col., readout sequence Added sentence: p.5, 1st col., fast rise time cu
The TIANSHAN Radio Experiment for Neutrino Detection
An antenna array devoted to the autonomous radio-detection of high energy
cosmic rays is being deployed on the site of the 21 cm array radio telescope in
XinJiang, China. Thanks in particular to the very good electromagnetic
environment of this remote experimental site, self-triggering on extensive air
showers induced by cosmic rays has been achieved with a small scale prototype
of the foreseen antenna array. We give here a detailed description of the
detector and present the first detection of extensive air showers with this
prototype.Comment: 37 pages, 15 figures. Astroparticle Physics (in press
First Dark Matter Results from the XENON100 Experiment
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62
kg of liquid xenon in an ultra-low background dual-phase time projection
chamber. In this letter, we present first dark matter results from the analysis
of 11.17 live days of non-blind data, acquired in October and November 2009. In
the selected fiducial target of 40 kg, and within the pre-defined signal
region, we observe no events and hence exclude spin-independent WIMP-nucleon
elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs
at 90% confidence level. Below 20 GeV/c^2, this result constrains the
interpretation of the CoGeNT and DAMA signals as being due to spin-independent,
elastic, light mass WIMP interactions.Comment: 5 pages, 5 figures. Matches published versio
Dark Matter Results from 100 Live Days of XENON100 Data
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.Comment: 5 pages, 5 figures; matches accepted versio
- …