449 research outputs found

    A comparative study between two different 3D reconstruction methods by bi-planar radiographic in upright posture: Biomod 3sand sterEOS®

    Get PDF
    ObjectivesThis study aims to evaluate the repeatability and reproducibility of two different methods of 3D reconstruction of the spine sterEOS® and BIOMODTM3S.Materials and methodsRepeatability and reproducibility study. Three observers performed the reconstructions: a radiologist, a X-ray technologist and a rehabilitation specialist, inexperienced in X-ray reading. The observers made these reconstructions with each modality: sterEOS® and BIOMODTM3S. The parameters investigated were Cobb angle, sagittal parameters (cyphosis, lordosis), determination of apical and junctional vertebrae, axial rotation of the apical vertebra, pelvic parameters and time of reconstruction. Statistical analyses were done using Intraclass Correlation Coefficient (ICC) for reproducibility and Student's t test for time of reconstruction.ResultsWe analyzed X-rays of 44 women (71%) and 18 men (29%) with a mean age of 44±20.8. The repeatability was correct, good or excellent depending on observer. The reproducibility inter-observer was correct to excellent (ICC 0.73–0.96) for every parameter except the axial rotation of the apical vertebrae and the determination of levels of junctional and apical vertebrae. The reproducibility of the axial rotation of apical vertebrae was low to good with BIOMODTM3S (ICC 0.15–0.81; ESM=7.5°). The reproducibility of the determination of levels of junctional and apical vertebrae was low to excellent with sterEOS® (ICC 0.36–0.90). With sterEOS®, the reproducibility was impaired by the inexperienced observator for some parameters. The 3D reconstructions with sterEOS® was significantly faster than with BIOMODTM3S (10.8min vs 14.2min, p<0.05).DiscussionParameters’ reproducibility is different depending on the system. The 3D reconstruction with sterEOS® is faster than with BIOMODTM3S. The reproducibility of BIOMODTM3S is less influenced by observator's experienc

    Light storage protocols in Tm:YAG

    Full text link
    We present two quantum memory protocols for solids: A stopped light approach based on spectral hole burning and the storage in an atomic frequency comb. These procedures are well adapted to the rare-earth ion doped crystals. We carefully clarify the critical steps of both. On one side, we show that the slowing-down due to hole-burning is sufficient to produce a complete mapping of field into the atomic system. On the other side, we explain the storage and retrieval mechanism of the Atomic Frequency Comb protocol. This two important stages are implemented experimentally in Tm3+^{3+}- doped yttrium-aluminum-garnet crystal

    A solid state light-matter interface at the single photon level

    Full text link
    Coherent and reversible mapping of quantum information between light and matter is an important experimental challenge in quantum information science. In particular, it is a decisive milestone for the implementation of quantum networks and quantum repeaters. So far, quantum interfaces between light and atoms have been demonstrated with atomic gases, and with single trapped atoms in cavities. Here we demonstrate the coherent and reversible mapping of a light field with less than one photon per pulse onto an ensemble of 10 millions atoms naturally trapped in a solid. This is achieved by coherently absorbing the light field in a suitably prepared solid state atomic medium. The state of the light is mapped onto collective atomic excitations on an optical transition and stored for a pre-programmed time up of to 1 mu s before being released in a well defined spatio-temporal mode as a result of a collective interference. The coherence of the process is verified by performing an interference experiment with two stored weak pulses with a variable phase relation. Visibilities of more than 95% are obtained, which demonstrates the high coherence of the mapping process at the single photon level. In addition, we show experimentally that our interface allows one to store and retrieve light fields in multiple temporal modes. Our results represent the first observation of collective enhancement at the single photon level in a solid and open the way to multimode solid state quantum memories as a promising alternative to atomic gases.Comment: 5 pages, 5 figures, version submitted on June 27 200

    Antibody to aquaporin-4 in the long-term course of neuromyelitis optica

    Get PDF
    Neuromyelitis optica (NMO) is a severe inflammatory CNS disorder of putative autoimmune aetiology, which predominantly affects the spinal cord and optic nerves. Recently, a highly specific serum reactivity to CNS microvessels, subpia and Virchow–Robin spaces was described in patients with NMO [called NMO–IgG (NMO–immunoglobulin G)]. Subsequently, aquaporin-4 (AQP4), the most abundant water channel in the CNS, was identified as its target antigen. Strong support for a pathogenic role of the antibody would come from studies demonstrating a correlation between AQP4-Ab (AQP4-antibody) titres and the clinical course of disease. In this study, we determined AQP4-Ab serum levels in 96 samples from eight NMO–IgG positive patients (median follow-up 62 months) in a newly developed fluorescence-based immunoprecipitation assay employing recombinant human AQP4. We found that AQP4-Ab serum levels correlate with clinical disease activity, with relapses being preceded by an up to 3-fold increase in AQP4-Ab titres, which was not paralleled by a rise in other serum autoantibodies in one patient. Moreover, AQP4-Ab titres were found to correlate with CD19 cell counts during therapy with rituximab. Treatment with immunosuppressants such as rituximab, azathioprine and cyclophosphamide resulted in a marked reduction in antibody levels and relapse rates. Our results demonstrate a strong relationship between AQP4-Abs and clinical state, and support the hypothesis that these antibodies are involved in the pathogenesis of NMO

    Spin-Glass State in CuGa2O4\rm CuGa_2O_4

    Full text link
    Magnetic susceptibility, magnetization, specific heat and positive muon spin relaxation (\musr) measurements have been used to characterize the magnetic ground-state of the spinel compound CuGa2O4\rm CuGa_2O_4. We observe a spin-glass transition of the S=1/2 Cu2+\rm Cu^{2+} spins below Tf=2.5K\rm T_f=2.5K characterized by a cusp in the susceptibility curve which suppressed when a magnetic field is applied. We show that the magnetization of CuGa2O4\rm CuGa_2O_4 depends on the magnetic histo Well below Tf\rm T_f, the muon signal resembles the dynamical Kubo-Toyabe expression reflecting that the spin freezing process in CuGa2O4\rm CuGa_2O_4 results Gaussian distribution of the magnetic moments. By means of Monte-Carlo simulati we obtain the relevant exchange integrals between the Cu2+\rm Cu^{2+} spins in this compound.Comment: 6 pages, 16 figure

    Spectroscopic investigations of a Ti:Tm:LiNbO3 waveguide for photon-echo quantum memory

    Full text link
    We report the fabrication and characterization of a Ti4+^{4+}:Tm3+^{3+}:LiNbO3_3 optical waveguide in view of photon-echo quantum memory applications. In particular, we investigated room- and cryogenic-temperature properties via absorption, spectral hole burning, photon echo, and Stark spectroscopy. We found radiative lifetimes of 82 μ\mus and 2.4 ms for the 3^3H4_4 and 3^3F4_4 levels, respectively, and a 44% branching ratio from the 3^3H4_{4} to the 3^3F4_4 level. We also measured an optical coherence time of 1.6 μ\mus for the 3^3H63_6\leftrightarrow{}^3H4_4, 795 nm wavelength transition, and investigated the limitation of spectral diffusion to spectral hole burning. Upon application of magnetic fields of a few hundred Gauss, we observed persistent spectral holes with lifetimes up to seconds. Furthermore, we measured a linear Stark shift of 25 kHz\cdotcm/V. Our results are promising for integrated, electro-optical, waveguide quantum memory for photons.Comment: 11 pages, 14 figure

    Magnetic properties of the frustrated AFM spinel ZnCr_2O_4 and the spin-glass Zn_{1-x}Cd_xCr_2O_4 (x=0.05,0.10)

    Full text link
    The TT-dependence (2- 400 K) of the electron paramagnetic resonance (EPR), magnetic susceptibility, χ(T)\chi (T), and specific heat, Cv(T)C_{v}(T), of the normalnormal antiferromagnetic (AFM) spinel ZnCr2_{2}O4_{4} and the spin-glass (SG) Zn1x_{1-x}Cdx_{x}Cr2_{2}O4_{4} (x=0.05,0.10x=0.05,0.10) is reported. These systems behave as a strongly frustrated AFM and SG with % T_{N} TG12 \approx T_{G}\approx 12 K and -400 K ΘCW500\gtrsim \Theta_{CW}\gtrsim -500 K. At high-TT the EPR intensity follows the χ(T)\chi (T) and the gg-value is TT-independent. The linewidth broadens as the temperature is lowered, suggesting the existence of short range AFM correlations in the paramagnetic phase. For ZnCr2_{2}O4_{4} the EPR intensity and χ(T)\chi (T) decreases below 90 K and 50 K, respectively. These results are discussed in terms of nearest-neighbor Cr3+^{3+} (S =3/2=3/2%) spin-coupled pairs with an exchange coupling of J/k| J/k| \approx 50 K. The appearance of small resonance modes for T17T\lesssim 17 K, the observation of a sharp drop in χ(T)\chi (T) and a strong peak in Cv(T)C_{v}(T) at TN=12T_{N}=12 K confirms, as previously reported, the existence of long range AFM correlations in the low-TT phase. A comparison with recent neutron diffraction experiments that found a near dispersionless excitation at 4.5 meV for TTNT\lesssim T_{N} and a continuous gapless spectrum for TTNT\gtrsim T_{N}, is also given.Comment: 17 pages, 8 figures, 1 Table. Submitted to Physical Review

    Alemtuzumab improves preexisting disability in active relapsing-remitting MS patients

    Get PDF
    Objective:\textbf{Objective:} To characterize effects of alemtuzumab treatment on measures of disability improvement in patients with relapsing-remitting multiple sclerosis (RRMS) with inadequate response (≥1 relapse) to prior therapy. Methods:\textbf{Methods:} Comparison of Alemtuzumab and Rebif Efficacy in Multiple Sclerosis (CARE-MS) II, a 2-year randomized, rater-blinded, active-controlled, head-to-head, phase 3 trial, compared efficacy and safety of alemtuzumab 12 mg with subcutaneous interferon-β-1a (SC IFN-β-1a) 44 μg in patients with RRMS. Prespecified and post hoc disability outcomes based on Expanded Disability Status Scale (EDSS), Multiple Sclerosis Functional Composite (MSFC), and Sloan low-contrast letter acuity (SLCLA) are reported, focusing on improvement of preexisting disability in addition to slowing of disability accumulation. Results:\textbf{Results:} Alemtuzumab-treated patients were more likely than SC IFN-β-1a-treated patients to show improvement in EDSS scores (pp < 0.0001) on all 7 functional systems. Significantly more alemtuzumab patients demonstrated 6-month confirmed disability improvement. The likelihood of improved vs stable/worsening MSFC scores was greater with alemtuzumab than SC IFN-β-1a (pp = 0.0300); improvement in MSFC scores with alemtuzumab was primarily driven by the upper limb coordination and dexterity domain. Alemtuzumab-treated patients had more favorable changes from baseline in SLCLA (2.5% contrast) scores (pp = 0.0014) and MSFC + SLCLA composite scores (pp = 0.0097) than SC IFN-β-1a-treated patients. Conclusions:\textbf{Conclusions:} In patients with RRMS and inadequate response to prior disease-modifying therapies, alemtuzumab provides greater benefits than SC IFN-β-1a across several disability outcomes, reflecting improvement of preexisting disabilities. Classification of evidence:\textbf{Classification of evidence:} This study provides Class I evidence (based on rater blinding and a balance in baseline characteristics between arms) that alemtuzumab modifies disability measures favorably compared with SC IFN-β-1a.Sanofi Genzyme, Bayer HealthCare Pharmaceutical

    The feasibility of measuring the activation of the trunk muscles in healthy older adults during trunk stability exercises

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As the older adult population increases, the potential functional and clinical burden of trunk muscle dysfunction may be significant. An evaluation of risk factors including the impact of the trunk muscles in terms of their temporal firing patterns, amplitudes of activation, and contribution to spinal stability is required. Therefore, the specific purpose of this study was to assess the feasibility of measuring the activation of trunk muscles in healthy older adults during specific leg exercises with trunk stabilization.</p> <p>Methods</p> <p>12 asymptomatic adults 65 to 75 years of age were included in the study. Participants performed a series of trunk stability exercises, while bilateral activation of abdominal and back extensor muscles was recorded by 24 pairs of Meditrace™ surface electrodes. Maximal voluntary isometric contractions (MVIC) were performed for electromyographic (EMG) normalization purposes. EMG waveforms were generated and amplitude measures as a percentage of MVIC were calculated along with ensemble average profiles. 3D kinematics data were also recorded, using an electromagnetic sensor placed at the left lateral iliac crest. Furthermore, a qualitative assessment was conducted to establish the participant's ability to complete all experimental tasks.</p> <p>Results</p> <p>Excellent quality abdominal muscle activation data were recorded during the tasks. Participants performed the trunk stability exercises with an unsteady, intermittent motion, but were able to keep pelvic motion to less than 10°. The EMG amplitudes showed that during these exercises, on average, the older adults recruited their abdominal muscles from 15–34% of MVIC and back extensors to less than 10% of MVIC. There were similarities among the abdominal muscle profiles. No participants reported pain during the testing session, although 3 (25%) of the participants reported delayed onset muscle soreness during follow up that was not functionally limiting.</p> <p>Conclusion</p> <p>Older adults were able to successfully complete the trunk stability protocol that was developed for younger adults with some minor modifications. The collected EMG amplitudes were higher than those reported in the literature for young healthy adults. The temporal waveforms for the abdominal muscles showed a degree of synchrony among muscles, except for the early activation from the internal oblique prior to lifting the leg off the table.</p
    corecore