1,662 research outputs found
Shot Noise in Linear Macroscopic Resistors
We report on a direct experimental evidence of shot noise in a linear
macroscopic resistor. The origin of the shot noise comes from the fluctuation
of the total number of charge carriers inside the resistor associated with
their diffusive motion under the condition that the dielectric relaxation time
becomes longer than the dynamic transit time. Present results show that neither
potential barriers nor the absence of inelastic scattering are necessary to
observe shot noise in electronic devices.Comment: 10 pages, 5 figure
Modelization of Thermal Fluctuations in G Protein-Coupled Receptors
We simulate the electrical properties of a device realized by a G protein
coupled receptor (GPCR), embedded in its membrane and in contact with two
metallic electrodes through which an external voltage is applied. To this
purpose, recently, we have proposed a model based on a coarse graining
description, which describes the protein as a network of elementary impedances.
The network is built from the knowledge of the positions of the C-alpha atoms
of the amino acids, which represent the nodes of the network. Since the
elementary impedances are taken depending of the inter-nodes distance, the
conformational change of the receptor induced by the capture of the ligand
results in a variation of the network impedance. On the other hand, the
fluctuations of the atomic positions due to thermal motion imply an impedance
noise, whose level is crucial to the purpose of an electrical detection of the
ligand capture by the GPCR. Here, in particular, we address this issue by
presenting a computational study of the impedance noise due to thermal
fluctuations of the atomic positions within a rhodopsin molecule. In our model,
the C-alpha atoms are treated as independent, isotropic, harmonic oscillators,
with amplitude depending on the temperature and on the position within the
protein (alpha-helix or loop). The relative fluctuation of the impedance is
then calculated for different temperatures.Comment: 5 pages, 2 figures, Proceeding of the 18-th International Conference
on Fluctuations and Noise, 19-23 September 2005, Salamanca, Spain -minor
proofreadings
Design of an air-flow microchamber for microparticles detec
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.A novel device, able to funnel a suspension of micrometric particles in air into a microchamber
equipped with a capacitive sensor, has been designed for the detection and characterization of particulate
matter (PM) in air. Numerical simulations have been performed to predict the trajectory of the microparticles
through the PDMS microchamber where the sensor is located. The feasibility of detecting single PM10
particles has been demonstrated by our experiments, where sequences of single industrial talc particles
(average diameter of 8 μm) have been detected and counted by a capacitive sensor. Our results indicate that
radical miniaturization of air quality monitors is possible and, therefore, pervasive monitoring of air
pollution will be soon feasible
Polidistrectual vascular involvement in Familial Hyperchilomicronemia
A 72-year-old man was referred to our clinic with a lipid profile, under combination therapy with a statin and ezetimibe, characterized by severe hypertriglyceridemia (7230 mg/dl), hypercholesterolemia (374 mg/dl), low HDL-cholesterol (17 mg/dl), and normal circulating Lp"a". The patient had undergone post-traumatic splenectomy and presented a history of systemic hypertension treated medically with well-controlled blood pressure. The patient had also presented in the past abdominal pain with subsequent diagnosis of chronic pancreatitis complicated by diabetes mellitus, well compensated when he came to our attention. Following a pathological exercise test, a coronary angiogram was performed which showed a significant stenosis of the right coronary artery, which was treated successfully with percutaneous coronary intervention. Clinical work-up revealed ectasia of the abdominal aorta (28 mm), non significant bilateral carotid artery disease, and peripheral artery disease of the femoral-popliteal axis symptomatic for intermittent claudication. A lipidogram was also performed and electrophoretic lipoprotein patterns did not vary 2 hours after heparin infusion, pointing to the existence of lipoprotein lipase deficit. Electrophoresis also showed a broadband of chylomicrons at baseline, at the beginning, and at the end of heparin infusion. Hyperchilomicronemia is a rare genetic disorder with an incidence of 1 per 1000000. Following diagnosis, our patient began plasma exchange therapy with subsequent improvement of his lipid profile. At the present time, he is regularly followed up at our clinic and non invasive imaging has excluded any significant progression of atherosclerosis after 2 years of therapy
Deployment and design of multiantenna solutions for fixed WiMAX systems
WiMax has already attracted the attention of operators and manifacturing industries for its promise of large throughput and coverage in broadband wireless access. However, towards the goal of an efficient deployment of this technology, a thorough analysis of its performance in presence of frequency reuse under realistic traffic conditions is mandatory. In particular, an important performance limiting factor is the inter-cell interference, which has strong non-stationary features. This paper investigates the deployment of multi-antenna base stations and the related design of signal processing algorithms for interference mitigation, for the uplink of IEEE 802.16-2004 systems. Extensive numerical results for realistic interference models show the advantages of the proposed multi-antenna system
Readmissions and the quality of care in patients hospitalized with heart failure
Objectives. Clinical practice guidelines based on the results of randomized clinical trials recommend that patients with heart failure due to left ventricular systolic dysfunction (LVSD) be treated with angiotensin-converting enzyme inhibitors (ACEI) at doses shown to reduce mortality and readmission. This study examined the relationship between ACEI use at discharge and readmission among patients with heart failure due to LVSD. Methods and results. Data were abstracted from the medical records of 2943 randomly selected patients hospitalized for heart failure in 50 hospitals. The outcome of interest was the number of readmissions occurring up to 21 months after discharge. Six-hundred and eleven patients were eligible for analysis. Compared with patients discharged at a recommended ACEI dose, patients not prescribed an ACEI at discharge had an adjusted rate ratio of readmission (RR) of 1.74 [95% confidence interval (CI) 1.22-2.48], while patients prescribed an ACEI at less than a recommended dose had an RR of 1.24 (95% CI 0.91-1.69) (P = 0.005 for the trend). Conclusion. Our results show that ACEI use at discharge in patients with LVSD is associated with decreased rate of readmission. These findings suggest that compliance with the ACEI prescribing recommendations listed in clinical practice guidelines for patients with heart failure due to LVSD confers benefi
Studio della quota di volo mediante GNSS, altimetro radar e barometro per rilievi di spettroscopia gamma da velivolo
Lo studio della distribuzione dei radionuclidi terrestri (238U, 232Th e 40K) realizzato mediante tecniche di spettroscopia gamma da velivolo è influenzato dalla quota a cui il rivelatore si trova rispetto al suolo. Un'incertezza del 10% a 100 m di altezza origina un errore nella stima del segnale gamma del 208Tl, appartenente alla catena di decadimenti del 232Th, dell’ordine del 7%. L'impiego di una nuova classe di spettrometri montati a bordo di UAV (Unmanned Aerial Vehicle) per raffinate misure in contesti ostili o remoti rende necessaria un'accurata stima in real time della quota di volo. Il Radgyro è un velivolo dedicato a survey multiparametrici, capace di trasportare strumentazione pari ad un payload massimo di 120 kg, tra cui quattro spettrometri gamma NaI(Tl). Una stazione inerziale con ricevitore integrato GNSS (Global Navigation Satellite System) restituisce l'assetto del velivolo con una frequenza massima di 400 Hz. Il velivolo è dotato di un network di tre ricevitori GNSS posizionati alle estremità della carena del velivolo. Un altimetro radar a 24 GHz rileva la quota con una frequenza di 60 Hz. La misura di pressione e temperatura consente di ricavare la quota barometrica a 2 Hz. Con l'obiettivo di studiare le incertezze associate alle misure della quota di volo acquisite dagli altimetri in relazione ai dati GNSS, sono stati realizzati tre voli sul mare in un range di altezze comprese tra 31 m e 249 m, per un totale di 4702 secondi di volo effettivo. Al termine dello studio è possibile concludere che l'errore complessivo delle abbondanze di K, U e Th aumenta di 7.7%, 0.5% e 2.7% rispettivamente, a causa delle incertezze della quota di volo
Low-mass e+e- pair production in 158 A GeV Pb-Au collisions at the CERN SPS, its dependence on multiplicity and transverse momentum
We report a measurement of low-mass electron pairs observed in 158
GeV/nucleon Pb-Au collisions. The pair yield integrated over the range of
invariant masses 0.2 < m < 2.0 GeV is enhanced by a factor of 3.5 +/- 0.4
(stat) +/- 0.9 (syst) over the expectation from neutral meson decays. As
observed previously in S-Au collisions, the enhancement is most pronounced in
the invariant-mass region 300-700 MeV. For Pb-Au we find evidence for a strong
increase of the enhancement with centrality. In addition, we show that the
enhancement covers a wide range in transverse momentum, but is largest at the
lowest observed pt.Comment: 17 pages, 4 figures, submitted to Phys.Lett.
- …
