293 research outputs found
Update of High Resolution (e,e'K^+) Hypernuclear Spectroscopy at Jefferson Lab's Hall A
Updated results of the experiment E94-107 hypernuclear spectroscopy in Hall A
of the Thomas Jefferson National Accelerator Facility (Jefferson Lab), are
presented. The experiment provides high resolution spectra of excitation energy
for 12B_\Lambda, 16N_\Lambda, and 9Li_\Lambda hypernuclei obtained by
electroproduction of strangeness. A new theoretical calculation for
12B_\Lambda, final results for 16N_\Lambda, and discussion of the preliminary
results of 9Li_\Lambda are reported.Comment: 8 pages, 5 figures, submitted to the proceedings of Hyp-X Conferenc
Thyroid surgery in geriatric patients: a literature review.
BACKGROUND: Thyroid disease is common in the elderly population. The incidence of hypothyroidism and multinodular goitre gradually increases with age. In view of a growth of aging population, we performed a literature review about the feasibility of thyroid surgery in the elderly. METHODS: We conducted a literature search in the PubMed database in September 2012 and all English-language publications on thyroidectomy in geriatric patients since 2002 were retrieved. The potential original articles mainly focusing on thyroidectomy in elderly patients were all identified and full texts were obtained and reviewed for further hand data retrieving. RESULTS: We retrieved five papers based on different primary end-point. Four were retrospective non randomized studies and one was prospective non randomized study. At last 65, 70, 75 and 80 years were used as an age cut-off. All studies evaluate the indications of thyroidectomy in geriatric patients, postoperative morbility and mortality. Only one study specifically assesses the rate of the rehospitalization after thyroidectomy among the elderly. CONCLUSIONS: Thyroid nodules are particularly important in elderly patients, as the incidence of malignancy increases and they are usually more aggressive tumors. An age of at least 70 years is an independent risk factor for complications after general surgery procedures. Thyroid surgery in patients aged 70 years or older is safe and the relatively high rate of thyroid carcinoma and toxic goiter may justify an aggressive approach. A programmed operation with a careful pre-operative evaluation and a risk stratification should make the surgical procedures less hazardous, specially in 80 years old patients with an high ASA score
BAG3 protein regulates stress- induced apoptosis in normal and neoplastic leukocytes
Co-chaperone proteins that share the Bcl-2-associated athanogene (BAG) domain are characterized by their interaction with a variety of partners, such as heat shock proteins (Hsp), steroid hormone receptors, Bcl-2, Raf-1 and others, involved in
regulating protein folding and a number of cellular processes,
including proliferation and apoptosis. Among BAG family
members there is BAG3, also known as CAIR-1 or Bis. BAG3 forms a complex with Hsp70,1,2,4,6 a protein able to modulate
apoptosis by interfering with cytochrome c release, apoptosome assembly and other events in the death process. In addition, BAG3 polypeptide binds to phospholipase C-g (PLC-g)4 or Bcl-2
protein.3,5 Due to such interaction with more than one
apoptosis-modulating factor, BAG3 can participate in apoptosis regulation. Indeed, its hyperexpression can decrease apoptosis induced via Bax or Fas in the human epithelial cell line HeLa3 or
by IL-3 deprivation in the murine hematopoietic cell line 32D.5
Furthermore, we recently showed that BAG3 downmodulation
enhances the apoptotic response to chemotherapy in human
primary B chronic lymphocytic leukemia cell
Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer
We report on the design and commissioning of two silica aerogel Cherenkov
detectors with different refractive indices. In particular, extraordinary
performance in terms of the number of detected photoelectrons was achieved
through an appropriate choice of PMT type and reflector, along with some design
considerations. After four years of operation, the number of detected
photoelectrons was found to be noticeably reduced in both detectors as a result
of contamination, yellowing, of the aerogel material. Along with the details of
the set-up, we illustrate the characteristics of the detectors during different
time periods and the probable causes of the contamination. In particular we
show that the replacement of the contaminated aerogel and parts of the
reflecting material has almost restored the initial performance of the
detectors.Comment: 18 pages, 9 Figures, 4 Tables, 44 Reference
Gastrointestinal Uses of Botulinum Toxin
Botulinum toxin (BT), one of the most powerful inhibitors that prevents the release of acetylcholine from nerve endings, represents an alternative therapeutic approach for “spastic” disorders of the gastrointestinal tract such as achalasia, gastroparesis, sphincter of Oddi dysfunction, chronic anal fissures, and pelvic floor dyssynergia. BT has proven to be safe and this allows it to be a valid alternative in patients at high risk of invasive procedures but long-term efficacy in many disorders has not been observed, primarily due to its relatively short duration of action. Administration of BT has a low rate of adverse reactions and complications. However, not all patients respond to BT therapy, and large randomized controlled trials are lacking for many conditions commonly treated with BT. The local injection of BT in some conditions becomes a useful tool to decide to switch to more invasive therapies. Since 1980, the toxin has rapidly transformed from lethal poison to a safe therapeutic agent, with a significant impact on the quality of life
Search for a new gauge boson in the Experiment (APEX)
We present a search at Jefferson Laboratory for new forces mediated by
sub-GeV vector bosons with weak coupling to electrons. Such a
particle can be produced in electron-nucleus fixed-target scattering and
then decay to an pair, producing a narrow resonance in the QED trident
spectrum. Using APEX test run data, we searched in the mass range 175--250 MeV,
found no evidence for an reaction, and set an upper limit of
. Our findings demonstrate that fixed-target
searches can explore a new, wide, and important range of masses and couplings
for sub-GeV forces.Comment: 5 pages, 5 figures, references adde
JLab Measurement of the He Charge Form Factor at Large Momentum Transfers
The charge form factor of ^4He has been extracted in the range 29 fm
fm from elastic electron scattering, detecting He
nuclei and electrons in coincidence with the High Resolution Spectrometers of
the Hall A Facility of Jefferson Lab. The results are in qualitative agreement
with realistic meson-nucleon theoretical calculations. The data have uncovered
a second diffraction minimum, which was predicted in the range of this
experiment, and rule out conclusively long-standing predictions of dimensional
scaling of high-energy amplitudes using quark counting.Comment: 4 pages, 2 figure
JLab Measurements of the 3He Form Factors at Large Momentum Transfers
The charge and magnetic form factors, FC and FM, of 3He have been extracted
in the kinematic range 25 fm-2 < Q2 < 61 fm-2 from elastic electron scattering
by detecting 3He recoil nuclei and electrons in coincidence with the High
Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The
measurements are indicative of a second diffraction minimum for the magnetic
form factor, which was predicted in the Q2 range of this experiment, and of a
continuing diffractive structure for the charge form factor. The data are in
qualitative agreement with theoretical calculations based on realistic
interactions and accurate methods to solve the three-body nuclear problem
Deeply Virtual Compton Scattering off the neutron
The present experiment exploits the interference between the Deeply Virtual
Compton Scattering (DVCS) and the Bethe-Heitler processes to extract the
imaginary part of DVCS amplitudes on the neutron and on the deuteron from the
helicity-dependent D cross section measured at =1.9
GeV and =0.36. We extract a linear combination of generalized parton
distributions (GPDs) particularly sensitive to , the least constrained
GPD. A model dependent constraint on the contribution of the up and down quarks
to the nucleon spin is deduced.Comment: Published in Phys. Rev. Let
Polarization transfer in the d(epol,e' ppol)n reaction up to Q^2=1.61 (GeV/c)^2
The recoil proton polarization was measured in the d(epol,e' ppol)n reaction
in Hall A of the Thomas Jefferson National Accelerator Facility (JLab). The
electron kinematics were centered on the quasielastic peak (x_{Bj}~1) and
included three values of the squared four-momentum transfer, Q^2=0.43, 1.00 and
1.61 (GeV/c)^2. For Q^2=0.43 and 1.61 (GeV/c)^2, the missing momentum, p_m, was
centered at zero while for Q^2=1.00 (GeV/c)^2 two values of p_m were chosen: 0
and 174 MeV/c. At low p_m, the Q^2 dependence of the longitudinal polarization,
P_z', is not well described by a state-of-the-art calculation. Further, at
higher p_m, a 3.5 sigma discrepancy was observed in the transverse
polarization, P_x'. Understanding the origin of these discrepancies is
important in order to confidently extract the neutron electric form factor from
the analogous d(epol,e' npol)p experiment.Comment: 6 pages, 4 figures; updated text, figures and table
- …