57 research outputs found

    Hyperammonemic Coma—Barking Up the Wrong Tree

    Get PDF
    Hepatic encephalopathy and myxedema coma share clinical features: coma, ascites, anemia, impaired liver functions, and a “metabolic” electroencephalogram (EEG). Hyperammonemia, a hallmark of hepatic encephalopathy, has also been described in hypothyroidism. Differentiation between the 2 conditions, recognition of their possible coexistence, and the consequent therapeutic implications are of utmost importance. We describe a case of an 82-year-old woman with a history of mild chronic liver disease who presented with hyperammonemic coma unresponsive to conventional therapy. Further investigation disclosed severe hypothyroidism. Thyroid hormone replacement resulted in gain of consciousness and normalization of hyperammonemia. In patients with an elevated ammonia level, altered mental status, and liver disease, who do not have a clear inciting event for liver disease decompensation, overwhelming evidence of hepatic decompensation, or who do not respond to appropriate therapy for hepatic encephalopathy, hypothyroidism should be considered and evaluated

    ALBIRA: A small animal PET/SPECT/CT imaging system

    Full text link
    Purpose: The authors have developed a trimodal PET/SPECT/CT scanner for small animal imaging. The gamma ray subsystems are based on monolithic crystals coupled to multianode photomultiplier tubes (MA-PMTs), while computed tomography (CT) comprises a commercially available microfocus x-ray tube and a CsI scintillator 2D pixelated flat panel x-ray detector. In this study the authors will report on the design and performance evaluation of the multimodal system. Methods: X-ray transmission measurements are performed based on cone-beam geometry. Individual projections were acquired by rotating the x-ray tube and the 2D flat panel detector, thus making possible a transaxial field of view (FOV) of roughly 80 mm in diameter and an axial FOV of 65 mm for the CT system. The single photon emission computed tomography (SPECT) component has a dual head detector geometry mounted on a rotating gantry. The distance between the SPECT module detectors can be varied in order to optimize specific user requirements, including variable FOV. The positron emission tomography (PET) system is made up of eight compact modules forming an octagon with an axial FOV of 40 mm and a transaxial FOV of 80 mm in diameter. The main CT image quality parameters (spatial resolution and uniformity) have been determined. In the case of the SPECT, the tomographic spatial resolution and system sensitivity have been evaluated with a99mTc solution using single-pinhole and multi-pinhole collimators. PET and SPECT images were reconstructed using three-dimensional (3D) maximum likelihood and ordered subset expectation maximization (MLEM and OSEM) algorithms developed by the authors, whereas the CT images were obtained using a 3D based FBP algorithm. Results: CT spatial resolution was 85μm while a uniformity of 2.7% was obtained for a water filled phantom at 45 kV. The SPECT spatial resolution was better than 0.8 mm measured with a Derenzo-like phantom for a FOV of 20 mm using a 1-mm pinhole aperture collimator. The full width at half-maximum PET radial spatial resolution at the center of the field of view was 1.55 mm. The SPECT system sensitivity for a FOV of 20 mm and 15% energy window was 700 cps/MBq (7.8 × 10−2%) using a multi-pinhole equipped with five apertures 1 mm in diameter, whereas the PET absolute sensitivity was 2% for a 350–650 keV energy window and a 5 ns timing window. Several animal images are also presented. Conclusions: The new small animal PET/SPECT/CT proposed here exhibits high performance, producing high-quality images suitable for studies with small animals. Monolithic design for PET and SPECT scintillator crystals reduces cost and complexity without significant performance degradation.This study was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant PROMETEO 2008/114. The authors also thank Brennan Holt for checking and correcting the text.Sánchez Martínez, F.; Orero Palomares, A.; Soriano Asensi, A.; Correcher Salvador, C.; Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.... (2013). ALBIRA: A small animal PET/SPECT/CT imaging system. Medical Physics. 40(5):5190601-5190611. https://doi.org/10.1118/1.4800798S5190601519061140

    Autoantibodies to muscarinic acetylcholine receptors found in patients with primary biliary cirrhosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Autoantibodies to the human muscarinic acetylcholine receptor of the M3 type (hmAchR M3) have been suggested to play an etiopathogenic role in Sjögren's syndrome. Primary biliary cirrhosis (PBC) often is associated with this syndrome. Therefore, we studied the co-presence of hmAchR M3 autoantibodies in patients with PBC.</p> <p>Methods</p> <p>Frequency of hmAchR M3 autoantibodies was assessed by Western blotting analysis as well as by an ELISA using a 25-mer peptide of the 2<sup>nd </sup>extracellular loop of hmAchR M3. Co-localization of hmAchR M3/PBC-specific autoantibodies was studied by confocal laser scanning microscopy. Finally, sera from patients with PBC as well as from healthy controls were tested.</p> <p>Results</p> <p>Western blotting analysis as well as results from ELISA testing revealed a significantly enhanced IgG reactivity in PBC patients in contrast to healthy controls. Co-localization of autoantibodies with the hmAchR M3 receptor-specific autoantibodies was observed in 10 out of 12 PBC-patients but none of the 5 healthy controls. Antibodies of the IgM type were not found to be affected.</p> <p>Conclusions</p> <p>For the first time, our data demonstrate the presence of autoantibodies to the hmAchR M3 in PBC patients. These findings might contribute to the understanding of the pathogenesis of this disease. Further studies have to focus on the functionality of hmAchR M3 autoantibodies in PBC patients.</p

    Poster display IV experimental and instrumentation

    Get PDF

    Corrigendum to ‘An international genome-wide meta-analysis of primary biliary cholangitis: Novel risk loci and candidate drugs’ [J Hepatol 2021;75(3):572–581]

    Get PDF

    The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI

    Get PDF

    Triton WR-1339-induced changes in serum lipids and biliary lipid secretion

    No full text
    corecore