277 research outputs found

    Halothane hepatitis with renal failure treated with hemodialysis and exchange transfusion

    Get PDF
    A 38-year-old white female, hepatitis B antigen negative, developed fluminating hepatic failure associated with oliguria and severe azotemia after two halothane anesthesia and without exposure to other hepatotoxic drugs or blood transfusions. She was treated with multiple hemodialysis and exchange blood transfusion. The combined treatment corrected the uremic abnormalities and improved her level of consciousness. The liver and kidney function gradually improved, and she made a complete recovery, the first recorded with hepatic and renal failure under these post-anesthetic conditions. Further evaluation of this combined treatment used for this patient is warranted. © 1974 The Japan Surgical Society

    The Lantern Vol. 5, No. 3, May 1937

    Get PDF
    • Dedication • Dr. McClure: An Ursinus Man • Roar, O Wind! • To the Ladies! • The Futility of Dying • The Symbolism of the British Crown • Oh! • It Might Have Been • Treat Yourself? • Three Writers • Hawaii in June • On Being a Twin • Black Magic • Triangle • Who Longs? • A Son Passes • Sing an Old-Fashioned Song • Questioning • An Argument About a Fish • That Morning Eye-Opener • Scoop for the Sun • The Dead Do Not Die Once • Give Us Timehttps://digitalcommons.ursinus.edu/lantern/1010/thumbnail.jp

    The Lantern Vol. 6, No. 1, December 1937

    Get PDF
    • After Thinking Things Over • Ho! Ho! The Mistletoe! • Unrealized Dreams • Two Preeminent Victorians • The Thing • Progression • It Wasn\u27t in the Lines • He Was the Most Perfect Man • College (C)lasses • Robins and Roses • The Commuter • When the Rose is Dead • Truth in Print • Alias Mike Romanoff • Winslow Homer • When I Was Young • Maurice Evans, a Great Shakespearean • Among Our Contributors • Of Manx and Man • A Sanguinary Pirate • Conversation Has an Adventure • Ursinus\u27 Neediest Casehttps://digitalcommons.ursinus.edu/lantern/1016/thumbnail.jp

    Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces.</p> <p>Materials and methods</p> <p>Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed.</p> <p>Results</p> <p>All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II.</p> <p>Conclusion</p> <p>Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate.</p

    Upper extremity fractures due to intimate partner violence versus accidental causes

    Get PDF
    This article is made available for unrestricted research re-use and secondary analysis in any form or be any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.PURPOSE: The purpose of this study is to evaluate the prevalence of intimate partner violence (IPV)-related upper extremity fractures (UEF) in women presenting to US emergency departments (ED) and compare their anatomic location to those due to accidental falls or strikes. METHODS: An Institutional Review Board exempt, retrospective review of prospectively collected data was performed using the National Electronic Injury Surveillance System's All Injury Program data from 2005 through 2015 for all UEF sustained in women 15 to 54 years old. Injuries based on reported IPV versus accidental falls or strikes were analyzed accounting for the weighted, stratified nature of the data. RESULTS: IPV-related UEF represented 1.7% of all UEF and 27.2% of all IPV fractures. The finger was the most common fracture site in IPV (34.3%) and accidental striking (53.3%) but accounted for only 10% of fall-related UEF. There was a higher proportion of shoulder fractures in IPV (9.2%) compared to accidental falls (7.4%) or strikes (2.9%). The odds of a finger fracture were 4.32 times greater in IPV than falling and of a shoulder fracture were 3.65 greater in IPV than accidental striking (p < 0.0001). CONCLUSIONS: While the finger is the most common site for IPV UEF, it is also the most common location for accidental striking. A lower proportion of finger fractures in fall and of shoulder/forearm fractures in accidental striking should prompt the radiologist to discuss the possibility of IPV with the ED physician in any woman presenting with a finger fracture due to fall and a shoulder/forearm fracture with a vague history of accidental striking

    Expanding the Versatility of Phage Display II: Improved Affinity Selection of Folded Domains on Protein VII and IX of the Filamentous Phage

    Get PDF
    Background: Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Methodology/Principal Findings: Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Conclusions/Significance: Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before. © 2011 Wälchli et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

    Low infection rates after 34,361 intramedullary nail operations in 55 low- and middle-income countries: Validation of the Surgical Implant Generation Network (SIGN) Online Surgical Database

    Get PDF
    Background: The Surgical Implant Generation Network (SIGN) supplies intramedullary (IM) nails for the treatment of long bone fractures free of charge to hospitals in low- and middle-income countries (LMICs). Most operations are reported to the SIGN Online Surgical Database (SOSD). Follow-up has been reported to be low, however. We wanted to examine the pattern of follow-up and to assess whether infection rates could be trusted. Patients and methods: The SOSD contained 36,454 IM nail surgeries in 55 LMICs. We excluded humerus and hip fractures, and fractures without a registered surgical approach. This left 34,361 IM nails for analysis. A generalized additive regression model (gam) was used to explore the association between follow-up rates and infection rates. Results: The overall follow-up rate in the SOSD was 18.1% (95% CI: 17.7–18.5) and national follow-up rates ranged from 0% to 74.2%. The overall infection rate was 0.7% (CI: 0.6–0.8) for femoral fractures and 1.2% (CI: 1.0–1.4) for tibial fractures. If only nails with a registered follow-up visit were included (n = 6,224), infection rates were 3.5% (CI: 3.0–4.1) for femoral fractures and 7.3% (CI: 6.2–8.4) for tibial fractures. We found an increase in infection rates with increasing follow-up rates up to a level of 5%. Follow-up above 5% did not result in increased infection rates. Interpretation: Reported infection rates after IM nailing in the SOSD appear to be reliable and could be used for further research. The low infection rates suggest that IM nailing is a safe procedure also in low- and middle-income countries.publishedVersio
    • …
    corecore