70 research outputs found

    Growing Healthy Kids: A School Enrichment Nutrition Education Program to Promote Healthy Behaviors for Children

    Get PDF
    The Growing Healthy Kids Program is a school-based nutrition education program that teaches students in Kindergarten through 2nd grade about healthy eating, physical activity, and how their body uses food. Pre- and post-knowledge data is collected from the students to measure changes in nutrition knowledge. In the first 2 years of the program, significant improvements in nutrition knowledge were found in all three grades. Teachers reported that students were more aware of the importance of nutrition and were making healthier meal and/or snack choices at the end of the program

    Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid Glaucoma Detection?

    Get PDF
    Purpose- To compare the diagnostic performance of automated imaging for glaucoma. Design- Prospective, direct comparison study. Participants- Adults with suspected glaucoma or ocular hypertension referred to hospital eye services in the United Kingdom. Methods- We evaluated 4 automated imaging test algorithms: the Heidelberg Retinal Tomography (HRT; Heidelberg Engineering, Heidelberg, Germany) glaucoma probability score (GPS), the HRT Moorfields regression analysis (MRA), scanning laser polarimetry (GDx enhanced corneal compensation; Glaucoma Diagnostics (GDx), Carl Zeiss Meditec, Dublin, CA) nerve fiber indicator (NFI), and Spectralis optical coherence tomography (OCT; Heidelberg Engineering) retinal nerve fiber layer (RNFL) classification. We defined abnormal tests as an automated classification of outside normal limits for HRT and OCT or NFI ≥ 56 (GDx). We conducted a sensitivity analysis, using borderline abnormal image classifications. The reference standard was clinical diagnosis by a masked glaucoma expert including standardized clinical assessment and automated perimetry. We analyzed 1 eye per patient (the one with more advanced disease). We also evaluated the performance according to severity and using a combination of 2 technologies. Main Outcome Measures- Sensitivity and specificity, likelihood ratios, diagnostic, odds ratio, and proportion of indeterminate tests. Results- We recruited 955 participants, and 943 were included in the analysis. The average age was 60.5 years (standard deviation, 13.8 years); 51.1% were women. Glaucoma was diagnosed in at least 1 eye in 16.8%; 32% of participants had no glaucoma-related findings. The HRT MRA had the highest sensitivity (87.0%; 95% confidence interval [CI], 80.2%–92.1%), but lowest specificity (63.9%; 95% CI, 60.2%–67.4%); GDx had the lowest sensitivity (35.1%; 95% CI, 27.0%–43.8%), but the highest specificity (97.2%; 95% CI, 95.6%–98.3%). The HRT GPS sensitivity was 81.5% (95% CI, 73.9%–87.6%), and specificity was 67.7% (95% CI, 64.2%–71.2%); OCT sensitivity was 76.9% (95% CI, 69.2%–83.4%), and specificity was 78.5% (95% CI, 75.4%–81.4%). Including only eyes with severe glaucoma, sensitivity increased: HRT MRA, HRT GPS, and OCT would miss 5% of eyes, and GDx would miss 21% of eyes. A combination of 2 different tests did not improve the accuracy substantially. Conclusions- Automated imaging technologies can aid clinicians in diagnosing glaucoma, but may not replace current strategies because they can miss some cases of severe glaucoma

    Macular thickness measurements in healthy Norwegian volunteers: an optical coherence tomography study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ethnic, intersubject, interoperator and intermachine differences in measured macular thickness seem to exist. Our purpose was to collect normative macular thickness data in Norwegians and to evaluate the association between macular thickness and age, gender, parity, and contraception status.</p> <p>Methods</p> <p>Retinal thickness was measured by Stratus Optical Coherence Tomography in healthy subjects. Mean macular thickness (MMT) was analyzed by repeated measures ANOVA with three dependent regional MMT-variables for interaction with age, gender, parity and oral contraception use. Exploratory correlation with age by the Pearson correlation test, both before and after stratification by gender was performed. Differences in MMT between older and younger subjects, between oral contraception users and non-users, as well as parous and nulliparous women were studied by post-hoc Student's t-tests.</p> <p>Results</p> <p>Central MMT in Norwegians was similar to values earlier reported in whites. MMT in central areas of 1 and 2.25 mm in diameter were higher in males than in females. In younger subjects (≤43 years) differences in MMT between genders were larger than in the mixed age group, whereas in older subjects (>43 years) the small differences did not reach the set significance level. No differences were found in minimal foveolar thickness (MMFT) between the genders in any age group.</p> <p>Mean foveal thickness (1 mm in diameter) was positively associated with age in females (r = 0.28, p = 0.03). MMFT was positively associated with age in all groups and reached significance both in females and in mixed gender group (r = 0.20, p = 0.041 and r = 0.26, p = 0.044 respectively).</p> <p>Mean foveal thickness and MMFT were significantly higher in parous than in nulliparous women, and age-adjusted ANOVA for MMFT revealed a borderline effect of parity.</p> <p>Conclusions</p> <p>Age and gender should be taken into consideration when establishing normal ranges for MMT in younger subjects. The gender difference in retinal thickness in young, but not older adults suggests a gonadal hormonal influence. The possible association between parity and retinal structure and its clinical relevance, should be studied further.</p

    The effect of image alignment on capillary blood flow measurement of the neuroretinal rim using the Heidelberg retina flowmeter

    No full text
    Aim: To examine the influence of image alignment on the repeatability of blood flow measurements of the optic nerve. Methods: 10 normal subjects were examined. Heidelberg retina tomograph imaging was performed to establish best location and focus for the temporal neuroretinal rim. Two high quality Heidelberg retina flowmeter (HRF) images were acquired for three methods of alignment: central, nasal, and temporal. A 10×10 pixel measurement window was selected and exactly reproduced on all images. The interquartile pixel values were used to calculate capillary flow. ANOVA, intraclass correlation coefficients (ICC) and the coefficient of repeatability (CoR) were used for analysis. Results: There was no difference between methods (p = 0.47) or between visits (p = 0.51). The ICCs were 0.83 for the central, 0.34 for the nasal, and 0.42 for the temporal alignment. The CoR was 31.5 for central (mean effect 235.1), 234.6 for nasal, and 256.7 for temporal alignment. Conclusion: Central alignment was the most repeatable method for the measurement of neuroretinal rim capillary blood flow using the HRF

    An enhancement module to improve the atypical birefringence pattern using scanning laser polarimetry with variable corneal compensation

    No full text
    AIM: To examine the repeatability and effect of an enhancement module on the severity of atypical birefringence patterns (ABP) using scanning laser polarimetery (SLP) with variable corneal compensation (VCC). METHODS: 16 patients with perimetric glaucoma (PG), 24 glaucoma suspect and pre‐perimetric glaucoma (GSPPG), and 12 normal volunteers (N) were included. One randomly selected eye of each volunteer was scanned three times using VCC and enhanced corneal compensation (ECC) at the same session by the same examiner. Typical scan scores (TSS) were calculated to evaluate the ABP. Coefficients of variability (CoV), coefficients of repeatability (CoR), and intraclass correlation coefficients (ICC) were calculated. RESULTS: The mean TSS using ECC (n = 97.3 (5.5), GSPPG = 98.3 (3.5), PG = 99.2 (2.3)) was significantly higher (p = 0.02, 0.01, and 0.006, respectively) compared with VCC (86.5 (14.4), 88.2 (18.2), and 83.4 (2.2), respectively). VCC parameters had a CoR of 1.2–6.5, CoV of 1.9%–8.6%, and ICC of 0.8–0.9. ECC parameters had a CoR of 0.5–4.0, CoV of 0.3%–5.1%, and ICC of 0.2–0.9. TSNIT average was the overall best performing parameter with the highest repeatability and least variability using both techniques (CoR<2.1, CoV<2%). CONCLUSION: The enhancement module significantly reduced the severity of ABP and maintained a high level of repeatability of retardation measurements

    Short-Term Enhancement of Visual Field Sensitivity in Glaucomatous Eyes Following Surgical Intraocular Pressure Reduction

    No full text
    To examine the hypothesis that surgical intraocular pressure (IOP) reduction leads to enhancement of visual field (VF) sensitivity in glaucomatous eyes. Prospective case-control study. Patients with uncontrolled IOP requiring trabeculectomy or aqueous drainage device were enrolled. Controls consisted of medically treated glaucoma patients with stable IOP and no change in medical therapy during follow-up. Two baseline preoperative VFs and 3 follow-up VF examinations at 1, 2, and 3 months postoperatively were used for analysis. The same number of VF examinations measured within an 18-month interval was used for control eyes. VF locations with significant change were defined as exceeding 95% test-retest confidence limits based upon the mean sensitivity using the 2 baseline VF exams. The number of significantly changing locations per eye and changes in mean and pattern standard deviation (PSD) from the mean baseline fields were compared between groups using a Poisson generalized estimating equation model. Thirty eyes of 30 surgically treated glaucoma patients and 41 eyes of 28 stable controls were enrolled. Postoperative IOP was decreased at follow-up 3 compared with baseline (P < .001) in the surgical eyes, but was similar in control eyes (P = .92). At follow-up 3, the number of test locations improving in central (P = .014) and peripheral (P = .019) VF locations was significantly greater in the surgical eyes. The number of eyes with improved PSD at follow-up 3 was significantly greater in the surgical eyes compared with controls (P = .02). Short-term enhancement of central and peripheral VF sensitivity occurs after surgical reduction of IOP in glaucomatous eyes and may represent a potential biomarker for retinal ganglion cell response to therapeutic interventions in glaucoma
    corecore