221 research outputs found

    A History of Until

    Get PDF
    Until is a notoriously difficult temporal operator as it is both existential and universal at the same time: A until B holds at the current time instant w iff either B holds at w or there exists a time instant w' in the future at which B holds and such that A holds in all the time instants between the current one and w'. This "ambivalent" nature poses a significant challenge when attempting to give deduction rules for until. In this paper, in contrast, we make explicit this duality of until to provide well-behaved natural deduction rules for linear-time logics by introducing a new temporal operator that allows us to formalize the "history" of until, i.e., the "internal" universal quantification over the time instants between the current one and w'. This approach provides the basis for formalizing deduction systems for temporal logics endowed with the until operator. For concreteness, we give here a labeled natural deduction system for a linear-time logic endowed with the new operator and show that, via a proper translation, such a system is also sound and complete with respect to the linear temporal logic LTL with until.Comment: 24 pages, full version of paper at Methods for Modalities 2009 (M4M-6

    Dissipative behaviour of reinforced-earth retaining structures under severe ground motion

    Get PDF
    This paper focuses on the seismic performance of geosynthetic-reinforced retaining walls (GRWs) that several evidences have shown to be generally adequate. This can be attributed to the dissipation of energy produced by the internal plastic mechanisms activated during the seismic shaking, and to an overall ductile behaviour related to the large deformation that can be accommodated by the soil-reinforcement system. Using a number of numerical computations, this work compares the behaviour of three idealized structures that were conceived in order to have a similar seismic resistance, that however is activated through different plastic mechanisms. The analyses include numerical pseudo-static computations, carried out iteratively to failure, and time-domain nonlinear dynamic analyses, in which acceleration time-histories were applied to the bottom boundary of the same numerical models used for the pseudo-static analyses. The results of the dynamic analyses were interpreted in the light of the plastic mechanisms obtained with the pseudo-static procedure, confirming that GRWs develop local plastic mechanisms during strong motion resulting in a significant improvement of their seismic performance

    SOLUZIONI TECNOLOGICHE INNOVATIVE PER LA PROSPEZIONE GEOFISICA IN AMBIENTE LAGUNARE

    Get PDF
    Innovative solutions for carry out geophysical surveys of coastal lagoons are presented

    Una procedura per il dimensionamento di muri in terra rinforzata soggetti ad eventi sismici intensi

    Get PDF
    In questa nota si presenta una procedura per il dimensionamento di muri in terra rinforzata mediante il metodo pseudo-statico. In essa, il coefficiente sismico k è calibrato su prefissati livelli di prestazione del muro, espressi in termini di valori limite degli spostamenti permanenti accumulati durante l’evento sismico. Un’equivalenza di upper bound tra gli spostamenti indotti da sisma e i valori di k è stata ottenuta applicando il metodo di Newmark al database di accelerogrammi italiani, aggiornato alle registrazioni del 2017, e correggendo le relazioni empiriche ottenute per tenere conto della forma dei meccanismi plastici interni alla zona rinforzata, ai quali corrisponde la massima domanda di resistenza dei rinforzi. Fissata la prestazione sismica, il muro viene quindi dimensionato per ottenere un coefficiente sismico critico associato ai meccanismi interni (kcint) inferiore a quello associato ai meccanismi esterni (kcext), così da promuovere l’attivazione di meccanismi plastici che prevedano la mobilitazione della resistenza del sistema terreno-rinforzo, dotato di rinforzi caratterizzati da adeguati livelli di duttilità

    Seismic design of geosynthetic-reinforced earth retaining walls following a pseudo-static approach

    Get PDF
    Geosynthetic-reinforced earth (GRE) retaining walls show a better performance than conventionally-designed walls during destructive earthquakes, due to their capability of redistributing seismic-induced deformations within the reinforced zone. In this paper, a recently-proposed method to design GRE walls is first recalled, where the wall is designed to trigger an internal plastic mechanism in the presence of strong earthquakes. Following a pseudo-static approach, the seismic coefficient k is therefore assumed equal to the internal seismic resistance of the wall kcint. The seismic coefficient is then calibrated against given seismic wall performance, expressed in terms of limit values of earthquake-induced displacements. Permanent displacements are evaluated through empirical relationships that were previously developed on the basis of a parametric integration of an updated Italian seismic database. Effectiveness of the proposed procedure is then demonstrated by assessing, through Finite Difference nonlinear dynamic analyses, the seismic performance of two walls, namely a GRE and a conventional gravity wall, characterised by the same seismic resistance but triggering an internal and external plastic mechanism, respectively. They are both subjected to a real strong motion, capable of activating a plastic mechanism. Results showed that lower permanent displacements are accumulated in the GRE wall where internal mechanisms are triggered

    Thermal noise and optomechanical features in the emission of a membrane-coupled compound cavity laser diode

    Get PDF
    We demonstrate the use of a compound optical cavity as linear displacement detector, by measuring the thermal motion of a silicon nitride suspended membrane acting as the external mirror of a near-infrared Littrow laser diode. Fluctuations in the laser optical power induced by the membrane vibrations are collected by a photodiode integrated within the laser, and then measured with a spectrum analyzer. The dynamics of the membrane driven by a piezoelectric actuator is investigated as a function of air pressure and actuator displacement in a homodyne configuration. The high Q-factor (∼3.4⋅104\sim 3.4\cdot 10^4 at 8.3⋅10−38.3 \cdot 10^{-3} mbar) of the fundamental mechanical mode at ∼73\sim 73 kHz guarantees a detection sensitivity high enough for direct measurement of thermal motion at room temperature (∼87\sim 87 pm RMS). The compound cavity system here introduced can be employed as a table-top, cost-effective linear displacement detector for cavity optomechanics. Furthermore, thanks to the strong optical nonlinearities of the laser compound cavity, these systems open new perspectives in the study of non-Markovian quantum properties at the mesoscale

    Biological application of Compressed Sensing Tomography in the Scanning Electron Microscope

    Get PDF
    The three-dimensional tomographic reconstruction of a biological sample, namely collagen fibrils in human dermal tissue, was obtained from a set of projection-images acquired in the Scanning Electron Microscope. A tailored strategy for the transmission imaging mode was implemented in the microscope and proved effective in acquiring the projections needed for the tomographic reconstruction. Suitable projection alignment and Compressed Sensing formulation were used to overcome the limitations arising from the experimental acquisition strategy and to improve the reconstruction of the sample. The undetermined problem of structure reconstruction from a set of projections, limited in number and angular range, was indeed supported by exploiting the sparsity of the object projected in the electron microscopy images. In particular, the proposed system was able to preserve the reconstruction accuracy even in presence of a significant reduction of experimental projections

    Surface-acoustic-wave counterflow micropumps for on-chip liquid motion control in two-dimensional microchannel arrays.

    Get PDF
    Fully controlled liquid injection and flow in hydrophobic polydimethylsiloxane (PDMS) two-dimensional microchannel arrays based on on-chip integrated, low-voltage-driven micropumps are demonstrated. Our architecture exploits the surface-acoustic-wave (SAW) induced counterflow mechanism and the effect of nebulization anisotropies at crossing areas owing to lateral propagating SAWs. We show that by selectively exciting single or multiple SAWs, fluids can be drawn from their reservoirs and moved towards selected positions of a microchannel grid. Splitting of the main liquid flow is also demonstrated by exploiting multiple SAW beams. As a demonstrator, we show simultaneous filling of two orthogonal microchannels. The present results show that SAW micropumps are good candidates for truly integrated on-chip fluidic networks allowing liquid control in arbitrarily shaped two-dimensional microchannel arrays

    Fabrication and testing of a high resolution extensometer based on resonant MEMS strain sensors

    No full text
    A novel type of linear extensometer with exceptionally high resolution of 4 nm based on MEMS resonant strain sensors bonded on steel and operating in a vacuum package is presented. The tool is implemented by means of a steel thin bar that can be pre-stressed in tension within two fixing anchors. The extension of the bar is detected by using two vacuum-packaged resonant MEMS double-ended tuning fork (DETF) sensors bonded on the bar with epoxy glue, one of which is utilized for temperature compensation. Both sensors are driven by a closed loop self-oscillating transresistance amplifier feedback scheme implemented on a PCB (Printed Circuit Board). On the same board, a microcontroller-based frequency measurement circuit is also implemented, which is able to count the square wave fronts of the MEMS oscillator output with a resolution of 20 nsec. The system provides a frequency noise of 0.2 Hz corresponding to an extension resolution of 4 nm for the extensometer. Nearly perfect temperature compensation of the frequency output is achieved in the temperature range 20-35°C using the reference sensor
    • …
    corecore