174 research outputs found

    Neutrinoless Double Beta Decay with SNO+

    Get PDF
    SNO+ will search for neutrinoless double beta decay by loading 780 tonnes of linear alkylbenzene liquid scintillator with O(tonne) of neodymium. Using natural Nd at 0.1% loading will provide 43.7 kg of 150Nd given its 5.6% abundance and allow the experiment to reach a sensitivity to the effective neutrino mass of 100-200 meV at 90% C.L in a 3 year run. The SNO+ detector has ultra low backgrounds with 7000 tonnes of water shielding and self-shielding of the scintillator. Distillation and several other purification techniques will be used with the aim of achieving Borexino levels of backgrounds. The experiment is fully funded and data taking with light-water will commence in 2012 with scintillator data following in 2013.Comment: 4 pages, 2 figures, prepared for TAUP 201

    Polarization measurements and their perspectives: PVLAS Phase II

    Full text link
    We sketch the proposal for a "PVLAS-Phase II" experiment. The main physics goal is to achieve the first direct observation of non-linear effects in electromagnetism predicted by QED and the measurement of the photon-photon scattering cross section at low energies (1-2 eV). Physical processes such as ALP and MCP production in a magnetic field could also be accessible if sensitive enough operation is reached. The short term experimental strategy is to compact as much as possible the dimensions of the apparatus in order to bring noise sources under control and to attain a sufficient sensitivity. We will also briefly mention future pespectives, such as a scheme to implement the resonant regeneration principle for the detection of ALPs.Comment: Paper submitted to the proceedings of the "4th Patras Workshop on Axions, WIMPs and WISPs", DESY, Hamburg Site /Germany, 18-21 June 200

    Masseteric-facial nerve neurorrhaphy: results of a case series

    Get PDF
    OBJECTIVE: Facial palsy is a well-known functional and esthetic problem that bothers most patients and affects their social relationships. When the time between the onset of paralysis and patient presentation is less than 18 months and the proximal stump of the injured facial nerve is not available, another nerve must be anastomosed to the facial nerve to reactivate its function. The masseteric nerve has recently gained popularity over the classic hypoglossus nerve as a new motor source because of its lower associated morbidity rate and the relative ease with which the patient can activate it. The aim of this work was to evaluate the effectiveness of masseteric-facial nerve neurorrhaphy for early facial reanimation. METHODS: Thirty-four consecutive patients (21 females, 13 males) with early unilateral facial paralysis underwent masseteric-facial nerve neurorrhaphy in which an interpositional nerve graft of the great auricular or sural nerve was placed. The time between the onset of paralysis and surgery ranged from 2 to 18 months (mean 13.3 months). Electromyography revealed mimetic muscle fibrillations in all the patients. Before surgery, all patients had House-Brackmann Grade VI facial nerve dysfunction. Twelve months after the onset of postoperative facial nerve reactivation, each patient underwent a clinical examination using the modified House-Brackmann grading scale as a guide. RESULTS: Overall, 91.2% of the patients experienced facial nerve function reactivation. Facial recovery began within 2-12 months (mean 6.3 months) with the restoration of facial symmetry at rest. According to the modified House-Brackmann grading scale, 5.9% of the patients had Grade I function, 61.8% Grade II, 20.6% Grade III, 2.9% Grade V, and 8.8% Grade VI. The morbidity rate was low; none of the patients could feel the loss of masseteric nerve function. There were only a few complications, including 1 case of postoperative bleeding (2.9%) and 2 local infections (5.9%), and a few patients complained about partial loss of sensitivity of the earlobe or a small area of the ankle and foot, depending on whether great auricular or sural nerves were harvested. CONCLUSIONS: The surgical technique described here seems to be efficient for the early treatment of facial paralysis and results in very little morbidity

    Temperature quenching in LAB based liquid scintillator

    Get PDF
    The effect of temperature changes on the light output of LAB based liquid scintillator is investigated in a range from −5-5 to 30\,^{\circ } C with α\alpha -particles and electrons in a small scale setup. Two PMTs observe the scintillator liquid inside a cylindrically shaped aluminum cuvette that is heated or cooled and the temperature dependent PMT sensitivity is monitored and corrected. The α\alpha -emitting isotopes in dissolved radon gas and in natural Samarium (bound to a LAB solution) excite the liquid scintillator mixtures and changes in light output with temperature variation are observed by fitting light output spectra. Furthermore, also changes in light output by compton electrons, which are generated from external calibration γ\gamma -ray sources, is analysed with varying temperature. Assuming a linear behaviour, a combined negative temperature coefficient of (−0.29±0.01) %/∘C{(-0.29 \pm 0.01)}{\,\%/^{\circ }}\hbox {C} is found. Considering hints for a particle type dependency, electrons show (−0.17±0.02) %/∘C{(-0.17 \pm 0.02)}{\,\%/^{\circ }}\hbox {C} , whereas the temperature dependency seems stronger for α\alpha -particles, with (−0.35±0.03) %/∘C{(-0.35 \pm 0.03)}{\,\%/^{\circ }}\hbox {C} . Due to a high sampling rate, a pulse shape analysis can be performed and shows an enhanced slow decay component at lower temperatures, pointing to reduced non-radiative triplet state de-excitations.Peer Reviewe

    Limits on Low Energy Photon-Photon Scattering from an Experiment on Magnetic Vacuum Birefringence

    Full text link
    Experimental bounds on induced vacuum magnetic birefringence can be used to improve present photon-photon scattering limits in the electronvolt energy range. Measurements with the PVLAS apparatus (E. Zavattini {\it et al.}, Phys. Rev. D {\bf77} (2008) 032006) at both λ=1064\lambda = 1064 nm and 532 nm lead to bounds on the parameter {\it Ae_{e}}, describing non linear effects in QED, of Ae(1064)<6.6⋅10−21A_{e}^{(1064)} < 6.6\cdot10^{-21} T−2^{-2} @ 1064 nm and Ae(532)<6.3⋅10−21A_{e}^{(532)} < 6.3\cdot10^{-21} T−2^{-2} @ 532 nm, respectively, at 95% confidence level, compared to the predicted value of Ae=1.32⋅10−24A_{e}=1.32\cdot10^{-24} T−2^{-2}. The total photon-photon scattering cross section may also be expressed in terms of AeA_e, setting bounds for unpolarized light of σγγ(1064)<4.6⋅10−62\sigma_{\gamma\gamma}^{(1064)} < 4.6\cdot10^{-62} m2^{2} and σγγ(532)<2.7⋅10−60\sigma_{\gamma\gamma}^{(532)} < 2.7\cdot10^{-60} m2^{2}. Compared to the expected QED scattering cross section these results are a factor of ≃2⋅107\simeq2\cdot10^{7} higher and represent an improvement of a factor about 500 on previous bounds based on ellipticity measurements and of a factor of about 101010^{10} on bounds based on direct stimulated scattering measurements

    New PVLAS results and limits on magnetically induced optical rotation and ellipticity in vacuum

    Full text link
    IIn 2006 the PVLAS collaboration reported the observation of an optical rotation generated in vacuum by a magnetic field. To further check against possible instrumental artifacts several upgrades to the PVLAS apparatus have been made during the last year. Two data taking runs, at the wavelength of 1064 nm, have been performed in the new configuration with magnetic field strengths of 2.3 T and 5 T. The 2.3 T field value was chosen in order to avoid stray fields. The new observations do not show the presence of a rotation signal down to the levels of 1.2⋅10−81.2\cdot 10^{-8} rad at 5 T and 1.0⋅10−81.0\cdot 10^{-8} rad at 2.3 T (at 95% c.l.) with 45000 passes in the magnetic field zone. In the same conditions no ellipticity signal was detected down to 1.4⋅10−81.4\cdot 10^{-8} at 2.3 T (at 95% c.l.), whereas at 5 T a signal is still present. The physical nature of this ellipticity as due to an effect depending on B2B^2 can be excluded by the measurement at 2.3 T. These new results completely exclude the previously published magnetically induced vacuum dichroism results, indicating that they were instrumental artifacts. These new results therefore also exclude the particle interpretation of the previous PVLAS results as due to a spin zero boson. The background ellipticity at 2.3 T can be used to determine a new limit on the total photon-photon scattering cross section of σγγ<4.5⋅10−34\sigma_{\gamma\gamma} < 4.5 \cdot10^{-34} barn at 95% c.l..Comment: 25 pages, 7 figures Main changes rel. to v.2: minor changes to abstract, replaced Figures 4,5,6, corrected typographical errors. Paper submitted to Physical Review

    Comparison of the LUNA 3He(alpha,gamma)7Be activation results with earlier measurements and model calculations

    Full text link
    Recently, the LUNA collaboration has carried out a high precision measurement on the 3He(alpha,gamma)7Be reaction cross section with both activation and on-line gamma-detection methods at unprecedented low energies. In this paper the results obtained with the activation method are summarized. The results are compared with previous activation experiments and the zero energy extrapolated astrophysical S factor is determined using different theoretical models.Comment: Accepted for publication in Journal of Physics
    • …
    corecore