109 research outputs found

    Pulsed-field magnetization of drilled bulk high-temperature superconductors: flux front propagation in the volume and on the surface

    Full text link
    We present a method for characterizing the propagation of the magnetic flux in an artificially drilled bulk high-temperature superconductor (HTS) during a pulsed-field magnetization. As the magnetic pulse penetrates the cylindrical sample, the magnetic flux density is measured simultaneously in 16 holes by means of microcoils that are placed across the median plane, i.e. at an equal distance from the top and bottom surfaces, and close to the surface of the sample. We discuss the time evolution of the magnetic flux density in the holes during a pulse and measure the time taken by the external magnetic flux to reach each hole. Our data show that the flux front moves faster in the median plane than on the surface when penetrating the sample edge; it then proceeds faster along the surface than in the bulk as it penetrates the sample further. Once the pulse is over, the trapped flux density inside the central hole is found to be about twice as large in the median plane than on the surface. This ratio is confirmed by modelling

    Modification of the trapped field in bulk high-temperature superconductors as a result of the drilling of a pattern of artificial columnar holes

    Full text link
    The trapped magnetic field is examined in bulk high-temperature superconductors that are artificially drilled along their c-axis. The influence of the hole pattern on the magnetization is studied and compared by means of numerical models and Hall probe mapping techniques. To this aim, we consider two bulk YBCO samples with a rectangular cross-section that are drilled each by six holes arranged either on a rectangular lattice (sample I) or on a centered rectangular lattice (sample II). For the numerical analysis, three different models are considered for calculating the trapped flux: (i), a two-dimensional (2D) Bean model neglecting demagnetizing effects and flux creep, (ii), a 2D finite-element model neglecting demagnetizing effects but incorporating magnetic relaxation in the form of an E-J power law, and, (iii), a 3D finite element analysis that takes into account both the finite height of the sample and flux creep effects. For the experimental analysis, the trapped magnetic flux density is measured above the sample surface by Hall probe mapping performed before and after the drilling process. The maximum trapped flux density in the drilled samples is found to be smaller than that in the plain samples. The smallest magnetization drop is found for sample II, with the centered rectangular lattice. This result is confirmed by the numerical models. In each sample, the relative drops that are calculated independently with the three different models are in good agreement. As observed experimentally, the magnetization drop calculated in the sample II is the smallest one and its relative value is comparable to the measured one. By contrast, the measured magnetization drop in sample (1) is much larger than that predicted by the simulations, most likely because of a change of the microstructure during the drilling process.Comment: Proceedings of EUCAS 09 conferenc

    Bulk high-Tc superconductors with drilled holes: how to arrange the holes to maximize the trapped magnetic flux ?

    Full text link
    Drilling holes in a bulk high-Tc superconductor enhances the oxygen annealing and the heat exchange with the cooling liquid. However, drilling holes also reduces the amount of magnetic flux that can be trapped in the sample. In this paper, we use the Bean model to study the magnetization and the current line distribution in drilled samples, as a function of the hole positions. A single hole perturbs the critical current flow over an extended region that is bounded by a discontinuity line, where the direction of the current density changes abruptly. We demonstrate that the trapped magnetic flux is maximized if the center of each hole is positioned on one of the discontinuity lines produced by the neighbouring holes. For a cylindrical sample, we construct a polar triangular hole pattern that exploits this principle; in such a lattice, the trapped field is ~20% higher than in a squared lattice, for which the holes do not lie on discontinuity lines. This result indicates that one can simultaneously enhance the oxygen annealing, the heat transfer, and maximize the trapped field

    JPCam: A 1.2Gpixel camera for the J-PAS survey

    Full text link
    JPCam is a 14-CCD mosaic camera, using the new e2v 9k-by-9k 10microm-pixel 16-channel detectors, to be deployed on a dedicated 2.55m wide-field telescope at the OAJ (Observatorio Astrofisico de Javalambre) in Aragon, Spain. The camera is designed to perform a Baryon Acoustic Oscillations (BAO) survey of the northern sky. The J-PAS survey strategy will use 54 relatively narrow-band (~13.8nm) filters equi-spaced between 370 and 920nm plus 3 broad-band filters to achieve unprecedented photometric red-shift accuracies for faint galaxies over ~8000 square degrees of sky. The cryostat, detector mosaic and read electronics is being supplied by e2v under contract to J-PAS while the mechanical structure, housing the shutter and filter assembly, is being designed and constructed by a Brazilian consortium led by INPE (Instituto Nacional de Pesquisas Espaciais). Four sets of 14 filters are placed in the ambient environment, just above the dewar window but directly in line with the detectors, leading to a mosaic having ~10mm gaps between each CCD. The massive 500mm aperture shutter is expected to be supplied by the Argelander-Institut fur Astronomie, Bonn. We will present an overview of JPCam, from the filter configuration through to the CCD mosaic camera. A brief outline of the main J-PAS science projects will be included.Comment: 11 pages and 9 figure

    Measurement of the magnetic field inside the holes of a drilled bulk high-Tc superconductor

    Full text link
    We use macroscopic holes drilled in a bulk YBCO superconductor to probe its magnetic properties in the volume of the sample. The sample is subjected to an AC magnetic flux with a density ranging from 30mT to 130mT and the flux in the superconductor is probed by miniature coils inserted in the holes. In a given hole, three different penetration regimes can be observed: (i) the shielded regime, where no magnetic flux threads the hole; (ii) the gradual penetration regime, where the waveform of the magnetic field has a clipped sine shape whose fundamental component scales with the applied field; and (iii) the flux concentration regime, where the waveform of the magnetic field is nearly a sine wave, with an amplitude exceeding that of the applied field by up to a factor of two. The distribution of the penetration regimes in the holes is compared with that of the magnetic flux density at the top and bottom surfaces of the sample, and is interpreted with the help of optical polarized light micrographs of these surfaces. We show that the measurement of the magnetic field inside the holes can be used as a local characterization of the bulk magnetic properties of the sample

    Randomised controlled trial of cervical radiofrequency lesions as a treatment for cervicogenic headache [ISRCTN07444684]

    Get PDF
    BACKGROUND: Cervicogenic headache (CEH) is a unilateral headache localised in the neck or occipital region, projecting to the frontal and temporal regions. Since the pathogenesis of this syndrome appears to have an anatomical basis in the cervical region, several surgical procedures aimed at reducing the nociceptive input on the cervical level, have been tested. We developed a sequence of various cervical radiofrequency neurotomies (facet joint denervations eventually followed by upper dorsal root ganglion neurotomies) that proved successful in a prospective pilot trial with 15 CEH patients. To further evaluate this sequential treatment program we conducted a randomised controlled trial METHODS: 30 patients with cervicogenic headache according to the Sjaastad diagnostic criteria, were randomised. 15 patients received a sequence of radiofrequency treatments (cervical facet joint denervation, followed by cervical dorsal root ganglion lesions when necessary), and the other 15 patients underwent local injections with steroid and anaesthetic at the greater occipital nerve, followed by transcutaneous electrical nerve stimulation (TENS) when necessary. Visual analogue scores for pain, global perceived effects scores, quality of life scores were assessed at 8, 16, 24 and 48 weeks. Patients also kept a headache diary. RESULTS: There were no statistically significant differences between the two treatment groups at any time point in the trial. CONCLUSION: We did not find evidence that radiofrequency treatment of cervical facet joints and upper dorsal root ganglions is a better treatment than the infiltration of the greater occipital nerve, followed by TENS for patients fulfilling the clinical criteria of cervicogenic headache

    Roles for Treg expansion and HMGB1 signaling through the TLR1-2-6 axis in determining the magnitude of the antigen-specific immune response to MVA85A

    Get PDF
    © 2013 Matsumiya et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are creditedA better understanding of the relationships between vaccine, immunogenicity and protection from disease would greatly facilitate vaccine development. Modified vaccinia virus Ankara expressing antigen 85A (MVA85A) is a novel tuberculosis vaccine candidate designed to enhance responses induced by BCG. Antigen-specific interferon-γ (IFN-γ) production is greatly enhanced by MVA85A, however the variability between healthy individuals is extensive. In this study we have sought to characterize the early changes in gene expression in humans following vaccination with MVA85A and relate these to long-term immunogenicity. Two days post-vaccination, MVA85A induces a strong interferon and inflammatory response. Separating volunteers into high and low responders on the basis of T cell responses to 85A peptides measured during the trial, an expansion of circulating CD4+ CD25+ Foxp3+ cells is seen in low but not high responders. Additionally, high levels of Toll-like Receptor (TLR) 1 on day of vaccination are associated with an increased response to antigen 85A. In a classification model, combined expression levels of TLR1, TICAM2 and CD14 on day of vaccination and CTLA4 and IL2Rα two days post-vaccination can classify high and low responders with over 80% accuracy. Furthermore, administering MVA85A in mice with anti-TLR2 antibodies may abrogate high responses, and neutralising antibodies to TLRs 1, 2 or 6 or HMGB1 decrease CXCL2 production during in vitro stimulation with MVA85A. HMGB1 is released into the supernatant following atimulation with MVA85A and we propose this signal may be the trigger activating the TLR pathway. This study suggests an important role for an endogenous ligand in innate sensing of MVA and demonstrates the importance of pattern recognition receptors and regulatory T cell responses in determining the magnitude of the antigen specific immune response to vaccination with MVA85A in humans.This work was funded by the Wellcome Trust. MM has a Wellcome Trust PhD studentship and HM is a Wellcome Trust Senior Fello

    The potential of behavioural activation for the treatment of chronic pain: An exploratory review

    Get PDF
    Background: A substantial proportion of the population have a persistent pain condition. In addition to considerable personal suffering, these conditions have a massive economic cost at a society level in terms of health expenditure and lost productivity. To address this immense public health problem, treatment approaches are needed that are based on scientifically supported theories and that are easy to disseminate and scalable. Method: An exploratory qualitative review of literature concerning the operant model of chronic pain, related psychological interventions, and a synopsis of existing intervention studies with a behavioural activation (BA) approach was undertaken. Results: Current treatments for chronic pain are multimodal, however early research showed promising results for operant-based behavioural intervention alone. Although originally developed for depression, BA is a good theoretical match for operant conceptions of chronic pain. Further, because of its relative simplicity, BA is appealing in terms of its potential ease of dissemination. Two case studies have used BA for individuals suffering from fibromyalgia and produced promising treatment outcomes. Conclusions: Further research investigating the efficacy of BA for chronic pain is justified. Such work should begin with more single subject experimental designs to explore how BA might be best applied and the generalisability of the approach

    An examination of the psychometric structure of the Multidimensional Pain Inventory in temporomandibular disorder patients: a confirmatory factor analysis

    Get PDF
    BACKGROUND: This paper seeks to analyse the psychometric and structural properties of the Multidimensional Pain Inventory (MPI) in a sample of temporomandibular disorder patients. METHODS: The internal consistency of the scales was obtained. Confirmatory Factor Analysis was carried out to test the MPI structure section by section in a sample of 114 temporomandibular disorder patients. RESULTS: Nearly all scales obtained good reliability indexes. The original structure could not be totally confirmed. However, with a few adjustments we obtained a satisfactory structural model of the MPI which was slightly different from the original: certain items and the Self control scale were eliminated; in two cases, two original scales were grouped in one factor, Solicitous and Distracting responses on the one hand, and Social activities and Away from home activities, on the other. CONCLUSION: The MPI has been demonstrated to be a reliable tool for the assessment of pain in temporomandibular disorder patients. Some divergences to be taken into account have been clarified
    • …
    corecore