14 research outputs found

    A paradoxical effect of levetiracetam may be seen in both children and adults with refractory epilepsy

    Get PDF
    AbstractThe aim of this prospective, uncontrolled clinical study was to evaluate the tolerability and the efficacy of levetiracetam as add-on treatment in 78 adults and 44 children with intractable epilepsy. The patients’ seizure frequency in the 8 weeks baseline period was compared to their seizure frequency after a mean follow-up of 8 months of treatment.A greater than 50% reduction in seizure frequency was achieved in 31 adults (40%) and 9 children (20%), of whom 7 adults (9%) and 3 children (7%) became seizure free. Most often levetiracetam was well tolerated, somnolence being the most frequently reported side effect (18% in adults and 7% in children). However, in 14 adults (18%) and 19 children (43%) levetiracetam was associated with an increase (>25%) in seizure frequency. Such a paradoxical effect, including the development of status epilepticus in three adults and four children, appeared most often in mentally retarded patients during the first 2 months of treatment, and on relatively high doses. Two children developed status epilepticus after 5 and 7 months, respectively.In conclusion, levetiracetam is usually well tolerated as add-on treatment in patients with difficult-to-treat partial onset seizures. By using a lower initial dose and a slower dose escalation than recommended by the manufacturer, a paradoxical effect may perhaps be avoided. In children, doses >20mgkg−1 per day should be introduced with caution

    Psykogene ikke-epileptiske anfall

    No full text

    The intrapleural volume threshold for ultrasound detection of pneumothoraces: An experimental study on porcine models

    Get PDF
    Background: Small pneumothoraxes (PTXs) may not impart an immediate threat to trauma patients after chest injuries. However, the amount of pleural air may increase and become a concern for patients who require positive pressure ventilation or air ambulance transport. Lung ultrasonography (US) is a reliable tool in finding intrapleural air, but the performance characteristics regarding the detection of small PTXs need to be defined. The study aimed to define the volume threshold of intrapleural air when PTXs are accurately diagnosed with US and compare this volume with that for chest x-ray (CXR). Methods: Air was insufflated into a unilateral pleural catheter in seven incremental steps (10, 25, 50, 100, 200, 350 and 500 mL) in 20 intubated porcine models, followed by a diagnostic evaluation with US and a supine anteroposterior CXR. The sonographers continued the US scanning until the PTXs could be ruled in, based on the pathognomonic US “lung point” sign. The corresponding threshold volume was noted. A senior radiologist interpreted the CXR images. Results: The mean threshold volume to confirm the diagnosis of PTX using US was 18 mL (standard deviation of 13 mL). Sixty-five percent of the PTXs were already diagnosed at 10 mL of intrapleural air; 25%, at 25 mL; and the last 10%, at 50 mL. At an air volume of 50 mL, the radiologist only identified four out of 20 PTXs in the CXR pictures; i.e., a sensitivity of 20% (95% CI: 7%, 44%). The sensitivity of CXR increased as a function of volume but leveled off at 67%, leaving one-third (1/3) of the PTXs unidentified after 500 mL of insufflated air. Conclusion: Lung US is very accurate in diagnosing even small amounts of intrapleural air and should be performed by clinicians treating chest trauma patients when PTX is among the differential diagnoses

    Vagal nerve stimulation—the Norwegian experience

    Get PDF
    AbstractThe purpose of this open retrospective study was to analyze the efficacy and tolerability of vagal nerve stimulation (VNS) in a Norwegian cohort of referral patients with refractory epileptic seizures. A total of 47 patients have been assessed after a mean follow-up time of 2.7 years. Mean age was 34.4 years, mean duration of epilepsy was 25.3 years. Forty-two patients (89%) had localization-related epilepsy, 36 patients (77%) had daily seizures. The patients had tried on average 9.5 antiepileptic drugs, and 12 patients (26%) had undergone epilepsy surgery.Sixteen patients (34%) had >50% reduction of seizure frequency with VNS, of which one patient became seizure free. The stimulation was generally well tolerated, but three patients requested the device removed because of troublesome side effects.We conclude that VNS is an efficacious and safe mode of treatment that should be offered to patients with medically and surgically refractory seizures

    Animal Laboratory Training Improves Lung Ultrasound Proficiency and Speed

    Get PDF
    Background: Although lung ultrasound (US) is accurate in diagnosing pneumothorax (PTX), the training requirements and methods necessary to perform US examinations must be defined. Objective: Our aim was to test whether animal laboratory training (ALT) improves the diagnostic competency and speed of PTX detection with US. Methods: Twenty medical students without lung US experience attended a 1-day course. Didactic, practical, and experimental lectures covered the basics of US physics, US machines, and lung US, followed by hands-on training to demonstrate the signs of normal lung sliding and PTX. Each student’s diagnostic skill level was tested with three subsequent examinations (at day 1, day 2, and 6-month follow-up) using experimentally induced PTX in porcine models. The outcome measures were sensitivity and specificity for US detection of PTX, self-reported diagnostic confidence, and scan time. Results: The students improved their skills between the initial two examinations: sensitivity increased from 81.7% (range 69.1% -90.1%) to 100.0% (range 94.3% -100.0%) and specificity increased from 90.0% (range 82.0%- 94.8%) to 98.9% (range 92.3%- 100.0%); with no deterioration 6 months later. There was a significant learning curve in choosing the correct answers (p = 0.018), a 1-point increase in the self-reported diagnostic confidence (7.8 8.8 on a 10-point scale; p < 0.05), and a 1-min reduction in the mean scan time per lung (p < 0.05). Conclusions: Without previous experience and after undergoing training in an animal laboratory, medical students improved their diagnostic proficiency and speed for PTX detection with US. Lung US is a basic technique that can be used by novices to accurately diagnose PTX
    corecore