3,666 research outputs found

    Evaluation of a Local Fault Detection Algorithm for HVDC Systems

    Get PDF
    A great increase in the amount of energy generated from clean and renewable sources integrated in the electric power system is expected worldwide in the coming years. High Voltage Direct Current (HVDC) systems are seen as a promising alternative to the traditional Alternating Current (AC) systems for the expansion of the electric power system. However, to achieve this vision, there are some remaining challenges regarding HVDC systems which need to be solved. One of the main challenges is related to fault detection and location in HVDC grids. This paper reviews the main protection algorithms available and presents the evaluation of a local fault detection algorithm for DC faults in a multi-terminal Voltage Source Conversion (VSC) based HVDC grid. The paper analyses the influence of the DC voltage sampling frequency and the cable length in the performance of the algorithm. © 2019, European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ).The authors thank the support from the Spanish Ministry of Economy, Industry and Competitiveness (project ENE2016-79145-R AEI/FEDER, UE) and GISEL research group IT1083-16), as well as from the University of the Basque Country UPV/EHU (research group funding PPG17/23)

    Radiation oncology in Latin speaking countries: A link between Europe and Latin America

    Get PDF

    Perfil InmunohistoquĂ­mico de los Tipos de Fibras en el MĂșsculo Vocal Humano

    Get PDF
    Galdames, IS (reprint author), Univ Talca, Escuela Fonoaudiol, Ave Lircay S-N,Oficina 104, Talca, Chile.he vocal muscle is a striated muscle with important functions in the emission of laryngeal sound and physiology of the voice. Therefore the knowledge of its constitution is the basis for the prevention and management of voice disorders. We used 10 samples from the middle third of vocal muscles obtained from autopsies of 6 male and 4 female subjects aged between 36 and 71 years. The samples were analyzed with BA-F8 monoclonal antibody to slow type I fibers, and antimyosin HC monoclonal antibody and antimyosin fast clone MY-32 antibody for types IIA, IIB, IIX, and neonatal fibers. We determined the distribution of the muscle fiber types and morphometric characteristics, evaluating the differences by sex and age group. The human vocal muscle presented a heterogeneous formation with a predominance of type II fibers at 51.99%, while type I fibers reached 48.01%; this difference was significant (p0.05). In conclusion, the human vocal muscle the fibers were predominantly type II fast

    Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i (R) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain

    Get PDF
    Urinary tract infections (UTI) are one of the most prevalent infections. A rapid and reliable screening method is useful to screen out negative samples. The objective of this study was to validate the Sysmex flow cytometer UF-1000i by evaluating its accuracy, linearity and carry-over; and define an optimal cut-off value to be used in routine practice in our hospital. For the validation of the UF-1000i cytometer, precision, linearity and carry-over were studied in samples with different counts of bacteria, leukocytes and erythrocytes. Between March and June 2016, urine samples were tested in the Clinical Microbiology Laboratory at University Miguel Servet Hospital, in Spain. Samples were analyzed with the Sysmex UF-1000i cytometer, and cultured. Growth of >= 10(5) CFUs/mL was considered positive. The validation study reveals that the precision in all the variables is acceptable; that there is a good linearity in the dilutions performed, obtaining values almost identical to those theoretically expected; and for the carry-over has practically null values. A total of 1, 220 urine specimens were included, of which 213 (17.4%) were culture positive. The optimal cut-off point of the bacteria-leukocyte combination was 138.8 bacteria or 119.8 leukocytes with an S and E of 95.3 and 70.4%, respectively. The UF-1000i cytometer is a valuable method to screen urine samples to effectively rule out UTI and, may contribute to the reduction of unnecessary urine cultures

    Editorial: Building Mathematical Models for Multicriteria and Multiobjective Applications

    Get PDF
    In our daily lives or professional settings, there are many decision problems involving multiple criteria, which may be conflicting and incommensurable. The complexity of real-world decision and the plethora of factors involved necessitate the implementation of sound theoretical frameworks for structuring decision-making processes. Multicriteria Decision Making/Aid (MCDM/A) and multiobjective methods can be highly useful for decision makers (DMs) in such tasks. Multicriteria and multiobjective approaches provide a wide variety of methodological tools for supporting the DMs when facing real-world decision problems when designing and analyzing mathematical models, representing both the preferences of decision makers and the various characteristics of the decision problems at hand in a number of areas

    Comparing Two Automated Techniques for the Primary Screening-Out of Urine Culture

    Get PDF
    Urinary tract infection is the most common human infection with a high morbidity. In primary care and hospital services, conventional urine culture is a key part of infection diagnosis but results take at least 24 h. Therefore, a rapid and reliable screening method is still needed to discard negative samples as quickly as possible and to reduce the laboratory workload. In this aspect, this study aims to compare the diagnostic performance between Sysmex OF-1000i and FUS200 systems in comparison to urine culture as the gold standard. From March to June 2016, 1, 220 urine samples collected at the clinical microbiology laboratory of the "Miguel Servet" hospital were studied in parallel with both analysers, and some technical features were evaluated to select the ideal equipment. The most balanced cut-off values taking into account bacteria or leukocyte counts were 138 bacteria/mu L or 119.8 leukocyte/pl for the OF-1000i (95.3% SE and 70.4% SP), and 5.7 bacteria/mu L or 4.3 leukocyte/mu L for the FUS200 (95.8% SE and 44.4% SP). The reduction of cultured plates was 37.4% with the FUS200 and 58.3% with the UF-1000i. This study shows that both techniques improve the workflow in the laboratory, but the OF-1000i has the highest specificity at any sensitivity and the FUS200 needs a shorter processing time

    An imbalance in Akt/mTOR is involved in the apoptotic and acantholytic processes in a mouse model of pemphigus vulgaris

    Get PDF
    Pemphigus vulgaris (PV) is an autoimmune blistering disease characterized by the presence of IgG autoantibodies against Dsg3. Our aim was to investigate the molecular events implicated in the development and localization of apoptosis and acantholysis in PV. We used a passive transfer mouse model together with immunohistochemical (IHC) techniques and the TUNEL assay, with quantification analysis in the basal layer of the epidermis. The activated signalling molecules analysed and apoptotic cells detected showed an identical localization. Herein, we found for the first time in vivo an increased expression of activated HER receptor isoforms in the basal layer in PV lesions. Besides, we observed the almost total lack of activated Akt compared with a higher level of activated mTOR within the basal cells of the epidermis. Our observations strongly support that the restriction of acantholysis to the basal layer may be due, at least in part, to the selective and increased presence of activated HER receptor isoforms in these cells. After phosphorylation of HER receptor isoforms, intracellular signalling pathways are activated in the basal layer. In addition, the imbalance in Akt/mTOR that takes place in the basal cells may provide intracellular signals necessary for the development of apoptosis and acantholysi
    • 

    corecore