40 research outputs found

    Evaluation of transrectal examination of cervical diameter by palpation in dairy cows

    Get PDF
    The objective of the study was to evaluate the reliability of a manual assessment of cervical diameter through palpation. In an in vivo trial, 64 Holstein-Friesian cows between 2 and 5d in milk (DIM) and between 21 and 27 DIM were examined by transrectal palpation by 3 investigators. For calculation of sensitivity and specificity, ultrasound-generated measurements were used as reference standard; a cervix >7.5 cm was categorized as large. The Pearson coefficient of correlation between the results of the 3 investigators and ultrasound-generated measurements was moderate (r=0.71, 0.74, and 0.51). The estimates generated by palpation by the 3 different investigators did not differ and were similar to measurements obtained by ultrasound. The coefficient of variation (CV) between the investigators and ultrasound was high (20.9, 18.7, and 32.0%). The mean difference between the investigators and the ultrasound was 0.60 cm (95% confidence interval: -2.4 to 3.6). Sensitivity was 28.6, 42.9, and 42.9%, and specificity was 100, 96.2, and 92.6% for the ability of the 3 investigators, respectively, to detect the 7.5-cm cutoff by palpation. Overall sensitivity and specificity for all 3 investigators, considering ultrasound as the reference, were 37.5 and 96.2%, respectively. In vitro, 24 wooden cylinders were used to represent cervical diameter and to examine the reliability, as well as sensitivity and specificity, of manual assessment of different diameters. The Pearson coefficient of correlation between the results of the investigators (n=11) and the actual diameters of the cylinders was 0.78. The CV between the investigators and the cylinders was 27.8%. The variation in the results was greater for cylinders with a larger diameter (3.5-cm diameter: mean ± standard deviation = 2.6 ± 0.9 cm; 10.5-cm diameter: mean ± standard deviation = 13.2 ± 4.0 cm). The estimate obtained by palpation for the 7.5-cm cylinder was 7.4 ± 2.1cm. Sensitivity was 79.4% and specificity 92.5%. After training one group of investigators, sensitivity and specificity improved to 85.9 and 94.4%, respectively. Transrectal palpation of the cervical diameter shows moderate repeatability and correlation and high variation between the investigators and the reference standards. Variability increased with larger diameters

    Evaluation of vaginoscopy for the diagnosis of clinical endometritis in dairy cows

    Get PDF
    The objective of the study was to evaluate the visual assessment of vaginal discharge by vaginoscopy for the diagnosis of clinical endometritis (CE) in dairy cows. In an in vivo trial, inter- and intraobserver repeatability of vaginoscopic examination (VE) was determined and the effect of transrectal palpation and experience of the investigator evaluated. Holstein-Friesian cows (n=380) were examined by vaginoscopy between 21 and 27 d in milk by 3 investigators twice. Vaginal discharge was categorized on a 4-point classification system (0=clear mucus, 1=mucus containing flecks of pus, 2=discharge containing less than 50% pus, 3=discharge containing more than 50% pus). Cows with a vaginal discharge score (VDS) of 0 were classified as healthy, whereas cows with a VDS of 1 to 3 were classified as having CE. Vaginal discharge score on a scale from 0 to 3 has moderate intra- (Cohen's kappa coefficient, Îș=0.55-0.60) and interobserver (Îș=0.44) repeatability. The prevalence of CE was comparable between the 3 investigators (first VE: 42.6, 34.8, and 38.7; second VE 46.8, 36.9, and 43.7%). Transrectal palpation (relative risk=0.96-1.03) or experience of the investigator (relative risk=0.9-1.1) did not affect results of VE. In an in vitro trial, sensitivity and specificity of visual assessment were determined utilizing 33 images showing yellow and pink areas in certain percentages as a reference standard. Pus was represented by yellow areas and the mucosa, including clear mucus, by pink areas. These images were visually assessed by 30 investigators via PowerPoint presentation (experiment 1) and by 23 investigators via a simulated vaginal examination (experiment 2) utilizing the same 4-point classification system. Sensitivity was 99.6 and 96.3% and specificity was 96.7 and 90.1% in experiments 1 and 2, respectively. The results provide evidence that a visual assessment conducted by vaginoscopic examination is not perfect but can be considered a reasonable measurement of vaginal discharge and is a practical tool to distinguish healthy from diseased cows

    EMG-Normalised Kinase Activation during Exercise Is Higher in Human Gastrocnemius Compared to Soleus Muscle

    Get PDF
    In mice, certain proteins show a highly confined expression in specific muscle groups. Also, resting and exercise/contraction-induced phosphorylation responses are higher in rat skeletal muscle with low mitochondrial content compared to muscles with high mitochondrial content, possibly related to differential reactive oxygen species (ROS)-scavenging ability or resting glycogen content. To evaluate these parameters in humans, biopsies from soleus, gastrocnemius and vastus lateralis muscles were taken before and after a 45 min inclined (15%) walking exercise bout at 69% VO2max aimed at simultaneously activating soleus and gastrocnemius in a comparable dynamic work-pattern. Hexokinase II and GLUT4 were 46–59% and 26–38% higher (p<0.05) in soleus compared to the two other muscles. The type I muscle fiber percentage was highest in soleus and lowest in vastus lateralis. No differences were found in protein expression of signalling proteins (AMPK subunits, eEF2, ERK1/2, TBC1D1 and 4), mitochondrial markers (F1 ATPase and COX1) or ROS-handling enzymes (SOD2 and catalase). Gastrocnemius was less active than soleus measured as EMG signal and glycogen use yet gastrocnemius displayed larger increases than soleus in phosphorylation of AMPK Thr172, eEF2 Thr56 and ERK 1/2 Thr202/Tyr204 when normalised to the mean relative EMG-signal. In conclusion, proteins with muscle-group restricted expression in mice do not show this pattern in human lower extremity muscle groups. Nonetheless the phosphorylation-response is greater for a number of kinase signalling pathways in human gastrocnemius than soleus at a given activation-intensity. This may be due to the combined subtle effects of a higher type I muscle fiber content and higher training status in soleus compared to gastrocnemius muscle

    Proxy evidence for state-dependence of climate sensitivity in the Eocene greenhouse

    Get PDF
    Despite recent advances, the link between the evolution of atmospheric CO2 and climate during the Eocene greenhouse remains uncertain. In particular, modelling studies suggest that in order to achieve the global warmth that characterised the early Eocene, warmer climates must be more sensitive to CO2 forcing than colder climates. Here, we test this assertion in the geological record by combining a new high-resolution boron isotope-based CO2 record with novel estimates of Global Mean Temperature. We find that Equilibrium Climate Sensitivity (ECS) was indeed higher during the warmest intervals of the Eocene, agreeing well with recent model simulations, and declined through the Eocene as global climate cooled. These observations indicate that the canonical IPCC range of ECS (1.5 to 4.5 °C per doubling) is unlikely to be appropriate for high-CO2 warm climates of the past, and the state dependency of ECS may play an increasingly important role in determining the state of future climate as the Earth continues to warm

    InterCarb: a community effort to improve interlaboratory standardization of the carbonate clumped isotope thermometer using carbonate standards

    Get PDF
    Increased use and improved methodology of carbonate clumped isotope thermometry has greatly enhanced our ability to interrogate a suite of Earth-system processes. However, interlaboratory discrepancies in quantifying carbonate clumped isotope (Δ47) measurements persist, and their specific sources remain unclear. To address interlaboratory differences, we first provide consensus values from the clumped isotope community for four carbonate standards relative to heated and equilibrated gases with 1,819 individual analyses from 10 laboratories. Then we analyzed the four carbonate standards along with three additional standards, spanning a broad range of ή47 and Δ47 values, for a total of 5,329 analyses on 25 individual mass spectrometers from 22 different laboratories. Treating three of the materials as known standards and the other four as unknowns, we find that the use of carbonate reference materials is a robust method for standardization that yields interlaboratory discrepancies entirely consistent with intralaboratory analytical uncertainties. Carbonate reference materials, along with measurement and data processing practices described herein, provide the carbonate clumped isotope community with a robust approach to achieve interlaboratory agreement as we continue to use and improve this powerful geochemical tool. We propose that carbonate clumped isotope data normalized to the carbonate reference materials described in this publication should be reported as Δ47 (I-CDES) values for Intercarb-Carbon Dioxide Equilibrium Scale

    Sevoflurane ameliorates gas exchange and attenuates lung damage in experimental lipopolysaccharide-induced lung injury

    Full text link
    BACKGROUND: Acute lung injury is a common complication in critically ill patients. Several studies suggest that volatile anesthetics have immunomodulating effects. The aim of the current study was to assess possible postconditioning with sevoflurane in an in vivo model of endotoxin-induced lung injury. METHODS: Rats were anesthetized, tracheotomized, and mechanically ventilated. Lipopolysaccharide (saline as control) was administered intratracheally. Upon injury after 2 h of propofol anesthesia, general anesthesia was continued with either sevoflurane or propofol for 4 h. Arterial blood gases were measured every 2 h. After 6 h of injury, bronchoalveolar lavage was performed and lungs were collected. Total cell count, albumin content, concentrations of the cytokines cytokine-induced neutrophil chemoattractant-1 and monocyte chemoattractant protein-1, and phospholipids were analyzed in bronchoalveolar lavage fluid. Expression of messenger RNA for the two cytokines and for surfactant protein B was determined in lung tissue. Histopathologic examination of the lung was performed. RESULTS: Significant improvement of the ratio of oxygen tension to inspired oxygen fraction was shown with sevoflurane (mean + or - SD: 243 + or - 94 mmHg [32.4 kPa]) compared with propofol (88 + or - 19 mmHg [11.7 kPa]). Total cell count representing effector cell recruitment as well as albumin content as a measure of lung permeability were significantly decreased in the sevoflurane-lipopolysaccharide group compared with the propofol-lipopolysaccharide group in bronchoalveolar lavage fluid. Expression of the cytokines protein in bronchoalveolar lavage fluid as well as messenger RNA in lung tissue was significantly lower in the sevoflurane-lipopolysaccharide group compared with the propofol-lipopolysaccharide group. CONCLUSIONS: Postconditioning with sevoflurane attenuates lung damage and preserves lung function in an in vivo model of acute lung injury

    Bending moments and types of failure of zirconia and titanium abutments with internal implant-abutment connections: a laboratory study

    Full text link
    PURPOSE: The aim of this study was to examine the bending moments and fracture patterns of different zirconia abutments with internal implant-abutment connections after static loading and to compare their bending moments to those of internally connected titanium abutments. Materials and METHODS: Three types of customized zirconia abutments (Straumann CARES abutments/Straumann BL implants [T1], Astra ZirDesign abutments/Astra Micro Thread OsseoSpeed implants [T2], Zirabut prototype abutments/Straumann SP implants [T3]) and one type of customized titanium abutment (control group, Straumann CARES abutments/Straumann BL implants [C]) were included. All abutments were one-piece abutments with an internal implant-abutment connection and were customized to the same shape but featured different implant-abutment connection designs. For each group, 20 identical copies of a master abutment were fabricated and fixed on their corresponding implants. Half of the abutments in each group were left unrestored, and the other 10 received glass-ceramic crowns. Static loading was applied at a 30-degree angle to the palatal surface until failure, and bending moments were calculated. The type of failure was characterized visually by dismounting the abutments and by examination of cross-sections of the embedded specimens. The results were analyzed statistically. RESULTS: The mean range of bending moments was higher for the unrestored groups (158.2 to 678.2 Ncm) than for the restored groups (117.9 to 419.4 Ncm). The highest mean bending moments were seen in the control group, both restored and unrestored (419.4/678.2 Ncm). Unrestored, T1 and T2 exhibited significantly higher bending moments than T3. This was also observed in the restored groups. CONCLUSION:Both the abutment material and the implant-abutment connection design affected the bending moments of abutments after static loading. Internally connected zirconia abutments with horizontal mismatch to the implant exhibited significantly higher bending moments compared to those without horizontal mismatch

    Proteome-wide identification of the endogenous ADP-ribosylome of mammalian cells and tissue

    Get PDF
    Although protein ADP-ribosylation is involved in diverse biological processes, it has remained a challenge to identify ADP-ribose acceptor sites. Here, we present an experimental workflow for sensitive and unbiased analysis of endogenous ADP-ribosylation sites, capable of detecting more than 900 modification sites in mammalian cells and mouse liver. In cells, we demonstrate that Lys residues, besides Glu, Asp and Arg residues, are the dominant in vivo targets of ADP-ribosylation during oxidative stress. In normal liver tissue, we find Arg residues to be the predominant modification site. The cellular distribution and biological processes that involve ADP-ribosylated proteins are different in cultured cells and liver tissue, in the latter of which the majority of sites were found to be in cytosolic and mitochondrial protein networks primarily associated with metabolism. Collectively, we describe a robust methodology for the assessment of the role of ADP-ribosylation and ADP-ribosyltransferases in physiological and pathological states

    Phase transformation and fracture load of stock and CAD/CAM-customized zirconia abutments after 1 year of clinical function

    Get PDF
    Objectives Functional loading and low-temperature degradation may give rise to impaired clinical long-term service of zirconia implant abutments. The aim of this study was to compare the fracture strength (primary outcome measure) and the volume percentage of monoclinic surface zirconia (m-ZrO2) of stock and CAD/CAM-customized zirconia implant abutments that functioned clinically for 1 year with geometrically identical pristine controls in an ex vivo experiment. Material and methods Twenty-three stock (ZirDesign (TM)) and 23 CAD/CAM-customized (Atlantis (TM)) zirconia implant abutments were retrieved after 1 year of clinical service. They were compared with pristine copies with respect to the volume fraction of the monoclinic phase using Raman spectroscopy and their fracture load by means of a single load-to-fracture test. Failure analysis was performed using optical and SEM microscopy. After verification of normal distribution, paired t tests were used for comparison of fracture loads between pristine and clinically aged specimen. All statistical tests employed a level of significance of alpha = 0.05. Results The fracture loads of the stock zirconia abutments were significantly (p <0.05) reduced to 78.8% (SD 29.5%) after one year of clinical function. For the CAD/CAM abutments, no reduction in fracture load was found. No m-ZrO2 volume percentages beyond the detection threshold of 5% were observed in any of the samples. Conclusions After 1 year of clinical service, no difference in fracture strength of the CAD/CAM-customized zirconia implant abutments could be demonstrated, whereas the stock zirconia abutments decreased considerably in fracture strength. No substantial tetragonal-to-monoclinic transformation was observed
    corecore