24 research outputs found

    Early Detection of Subsurface Fatigue Cracks in Rolling Element Bearings by the Knowledge-Based Analysis of Acoustic Emission

    Get PDF
    Aiming at early detection of subsurface cracks induced by contact fatigue in rotating machinery, the knowledge-based data analysis algorithm is proposed for health condition monitoring through the analysis of acoustic emission (AE) time series. A robust fault detector is proposed, and its effectiveness was demonstrated for the long-term durability test of a roller made of case-hardened steel. The reliability of subsurface crack detection was proven using independent ultrasonic inspections carried out periodically during the test. Subsurface cracks as small as 0.5 mm were identified, and their steady growth was tracked by the proposed AE technique. Challenges and perspectives of the proposed methodology are unveiled and discussed.publishedVersio

    What causes treatment failure - the patient, primary care, secondary care or inadequate interaction in the health services?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Optimal treatment gives complete relief of symptoms of many disorders. But even if such treatment is available, some patients have persisting complaints. One disorder, from which the patients should achieve complete relief of symptoms with medical or surgical treatment, is gastroesophageal reflux disease (GERD). Despite the fact that such treatment is cheap, safe and easily available; some patients have persistent complaints after contact with the health services. This study evaluates the causes of treatment failure.</p> <p>Methods</p> <p>Twelve patients with GERD and persistent complaints had a semi-structured interview which focused on the patients' evaluation of treatment failure. The interviews were taped, transcribed and evaluated by 18 physicians, (six general practitioners, six gastroenterologists and six gastrointestinal surgeons) who completed a questionnaire for each patient. The questionnaires were scored, and the relative responsibility for the failure was attributed to the patient, primary care, secondary care and interaction in the health services.</p> <p>Results</p> <p>Failing interaction in the health services was the most important cause of treatment failure, followed by failure in primary care, secondary care and the patient himself; the relative responsibilities were 35%, 28%, 27% and 10% respectively. There was satisfactory agreement about the causes between doctors with different specialities, but significant inter-individual differences between the doctors. The causes of the failures differed between the patients.</p> <p>Conclusions</p> <p>Treatment failure is a complex problem. Inadequate interaction in the health services seems to be important. Improved communication between parts of the health services and with the patients are areas of improvement.</p

    Marine Benthic Diatoms Contain Compounds Able to Induce Leukemia Cell Death and Modulate Blood Platelet Activity

    Get PDF
    In spite of the high abundance and species diversity of diatoms, only a few bioactive compounds from them have been described. The present study reveals a high number of mammalian cell death inducing substances in biofilm-associated diatoms sampled from the intertidal zone. Extracts from the genera Melosira, Amphora, Phaeodactylum and Nitzschia were all found to induce leukemia cell death, with either classical apoptotic or autophagic features. Several extracts also contained inhibitors of thrombin-induced blood platelet activation. Some of this activity was caused by a high content of adenosine in the diatoms, ranging from 0.07 to 0.31 Îźg/mg dry weight. However, most of the bioactivity was adenosine deaminase-resistant. An adenosine deaminase-resistant active fraction from one of the extracts was partially purified and shown to induce apoptosis with a distinct phenotype. The results show that benthic diatoms typically found in the intertidal zone may represent a richer source of interesting bioactive compounds than hitherto recognized

    Gastronet survey on the use of one- or two-person technique for colonoscopy insertion

    Get PDF
    Background Usually, colonoscopy insertion is performed by the colonoscopist (one-person technique). Quite common in the early days of endoscopy, the assisting nurse is now only rarely doing the insertion (two-person technique). Using the Norwegian national endoscopy quality assurance (QA) programme, Gastronet, we wanted to explore the extent of two-person technique practice and look into possible differences in performance and QA output measures. Methods 100 colonoscopists in 18 colonoscopy centres having reported their colonoscopies to Gastronet between January and December 2009 were asked if they practiced one- or two-person technique during insertion of the colonoscope. They were categorized accordingly for comparative analyses of QA indicators. Results 75 endoscopists responded to the survey (representing 9368 colonoscopies) - 62 of them (83%) applied one-person technique and 13 (17%) two-person technique. Patients age and sex distributions and indications for colonoscopy were also similar in the two groups. Caecal intubation was 96% in the two-person group compared to 92% in the one-person group (p < 0.001). Pain reports were similar in the groups, but time to the caecum was shorter and the use of sedation less in the two-person group. Conclusion Two-person technique for colonoscope insertion was practiced by a considerable minority of endoscopists (17%). QA indicators were either similar to or better than one-person technique. This suggests that there may be some beneficial elements to this technique worth exploring and try to import into the much preferred one-person insertion technique

    Early Detection of Subsurface Fatigue Cracks in Rolling Element Bearings by the Knowledge-Based Analysis of Acoustic Emission

    No full text
    Aiming at early detection of subsurface cracks induced by contact fatigue in rotating machinery, the knowledge-based data analysis algorithm is proposed for health condition monitoring through the analysis of acoustic emission (AE) time series. A robust fault detector is proposed, and its effectiveness was demonstrated for the long-term durability test of a roller made of case-hardened steel. The reliability of subsurface crack detection was proven using independent ultrasonic inspections carried out periodically during the test. Subsurface cracks as small as 0.5 mm were identified, and their steady growth was tracked by the proposed AE technique. Challenges and perspectives of the proposed methodology are unveiled and discussed

    What causes treatment failure - the patient, primary care, secondary care or inadequate interaction in the health services?

    No full text
    Background: Optimal treatment gives complete relief of symptoms of many disorders. But even if such treatment is available, some patients have persisting complaints. One disorder, from which the patients should achieve complete relief of symptoms with medical or surgical treatment, is gastroesophageal reflux disease (GERD). Despite the fact that such treatment is cheap, safe and easily available; some patients have persistent complaints after contact with the health services. This study evaluates the causes of treatment failure. Methods: Twelve patients with GERD and persistent complaints had a semi-structured interview which focused on the patients’ evaluation of treatment failure. The interviews were taped, transcribed and evaluated by 18 physicians, (six general practitioners, six gastroenterologists and six gastrointestinal surgeons) who completed a questionnaire for each patient. The questionnaires were scored, and the relative responsibility for the failure was attributed to the patient, primary care, secondary care and interaction in the health services. Results: Failing interaction in the health services was the most important cause of treatment failure, followed by failure in primary care, secondary care and the patient himself; the relative responsibilities were 35%, 28%, 27% and 10% respectively. There was satisfactory agreement about the causes between doctors with different specialities, but significant inter-individual differences between the doctors. The causes of the failures differed between the patients. Conclusions: Treatment failure is a complex problem. Inadequate interaction in the health services seems to be important. Improved communication between parts of the health services and with the patients are areas of improvement
    corecore