32,063 research outputs found
Development of a relatchable cover mechanism for a cryogenic IR-sensor
A cover mechanism for use on the Infrared Background Signature Survey (IBSS) cryostat was developed. The IBSS IR-instrument is scheduled for STS launch in early 1991 as a payload of the Shuttle Payload Satellite (SPS) 2. The cover is hinged, with a motorized rope drive. During ground processing, launch, entry, and landing, the cryostat, which houses the IR-instrument, is required to be a sealed vacuum tight container for cooling purposes and contamination prevention. When on orbit, the cover is opened to provide an unobstructed field of view for the IR-instrument. A positive seal is accomplished through the use of latch mechanism. The cover and the latch are driven by a common redundant actuator consisting of dc motors, spur gears, and a differential gear. Hall probe limit switches and position sensors (rotary variable transformer) are used to determine the position of the cover and the latch. The cover mechanism was successfully qualified for thermal vacuum (-25 to 35 C), acoustic noise, vibration (6 Gs sine, 9.7 G RMS) and life cycles. Constricting requirements, mechanical and electronic control design, specific design details, test results of functional performance, and environmental and life tests are described
A calcium ion in a cavity as a controlled single-photon source
We present a single calcium ion, coupled to a high-finesse cavity, as an almost ideal system for the controlled generation of single photons. Photons from a pump beam are Raman-scattered by the ion into the cavity mode, which subsequently emits the photon into a well-defined output channel. In contrast with comparable atomic systems, the ion is localized at a fixed position in the cavity mode for indefinite times, enabling truly continuous operation of the device. We have performed numeric calculations to assess the performance of the system and present the first experimental indication of single-photon emission in our set-up
Hydrothermal synthesis of perovskite and pyrochlore powders of potassium tantalate
Potassium tantalate powders were hydrothermally synthesized at 100 to 200 °C in 4 to 15 M aqueous KOH solutions. A defect pyrochlore, Kta_(2)O_(5)(OH). nH2O (n ≈ 1.4), was obtained at 4 M KOH, but at 7–12 M KOH, this pyrochlore was gradually replaced by a defect perovskite as the stable phase. At 15 M KOH, there was no intermediate pyrochlore, only a defect perovskite, K_(0.85)Ta_(0.92)O_(2.43)(OH)_(0.57) 0.15H_(2)O. Synthesis at higher KOH concentrations led to greater incorporation of protons in the perovskite structures. The potassium vacancies required for charge compensation of incorporated protons could accommodate water molecules in the perovskite structure
Deterministic cavity quantum electrodynamics with trapped ions
We have employed radio-frequency trapping to localize a single 40Ca+-ion in a high-finesse optical cavity. By means of laser Doppler cooling, the position spread of the ion's wavefunction along the cavity axis was reduced to 42 nm, a fraction of the resonance wavelength of ionized calcium (λ = 397 nm). By controlling the position of the ion in the optical field, continuous and completely deterministic coupling of ion and field was realized. The precise three-dimensional location of the ion in the cavity was measured by observing the fluorescent light emitted upon excitation in the cavity field. The single-ion system is ideally suited to implement cavity quantum electrodynamics under cw conditions. To this end we operate the cavity on the D3/2–P1/2 transition of 40Ca+ (λ = 866 nm). Applications include the controlled generation of single-photon pulses with high efficiency and two-ion quantum gates
Markov Chain Beam Randomization: a study of the impact of PLANCK beam measurement errors on cosmological parameter estimation
We introduce a new method to propagate uncertainties in the beam shapes used
to measure the cosmic microwave background to cosmological parameters
determined from those measurements. The method, which we call Markov Chain Beam
Randomization, MCBR, randomly samples from a set of templates or functions that
describe the beam uncertainties. The method is much faster than direct
numerical integration over systematic `nuisance' parameters, and is not
restricted to simple, idealized cases as is analytic marginalization. It does
not assume the data are normally distributed, and does not require Gaussian
priors on the specific systematic uncertainties. We show that MCBR properly
accounts for and provides the marginalized errors of the parameters. The method
can be generalized and used to propagate any systematic uncertainties for which
a set of templates is available. We apply the method to the Planck satellite,
and consider future experiments. Beam measurement errors should have a small
effect on cosmological parameters as long as the beam fitting is performed
after removal of 1/f noise.Comment: 17 pages, 23 figures, revised version with improved explanation of
the MCBR and overall wording. Accepted for publication in Astronomy and
Astrophysics (to appear in the Planck pre-launch special issue
Hydrothermal synthesis of KNbO_3 and NaNbO_3 powders
Orthorhombic KNbO_3 and NaNbO_3 powders were hydrothermally synthesized in KOH and NaOH solutions (6.7–15 M) at 150 and 200 °C. An intermediate hexaniobate species formed first before eventually converting to the perovskite phase. For synthesis in KOH solutions, the stability of the intermediate hexaniobate ion increased with decreasing KOH concentrations and temperatures. This led to significant variations in the induction periods and accounted for the large disparity in the mass of recovered powder for different processing parameters. It is also believed that protons were incorporated in the lattice of the as-synthesized KNbO_3 powders as water molecules and hydroxyl ions
Entanglement genesis by ancilla-based parity measurement in 2D circuit QED
We present an indirect two-qubit parity meter in planar circuit quantum
electrodynamics, realized by discrete interaction with an ancilla and a
subsequent projective ancilla measurement with a dedicated, dispersively
coupled resonator. Quantum process tomography and successful entanglement by
measurement demonstrate that the meter is intrinsically quantum non-demolition.
Separate interaction and measurement steps allow commencing subsequent data
qubit operations in parallel with ancilla measurement, offering time savings
over continuous schemes.Comment: 5 pages, 4 figures; supplemental material with 5 figure
Magnetooptical sum rules close to the Mott transition
We derive new sum rules for the real and imaginary parts of the
frequency-dependent Hall constant and Hall conductivity. As an example, we
discuss their relevance to the doped Mott insulator that we describe within the
dynamical mean-field theory of strongly correlated electron systems.Comment: 4 pages, 4 ps figures; accepted for publication in PR
Quantum-state input-output relations for absorbing cavities
The quantized electromagnetic field inside and outside an absorbing high-
cavity is studied, with special emphasis on the absorption losses in the
coupling mirror and their influence on the outgoing field. Generalized operator
input-output relations are derived, which are used to calculate the Wigner
function of the outgoing field. To illustrate the theory, the preparation of
the outgoing field in a Schr\"{o}dinger cat-like state is discussed.Comment: 12 pages, 5 eps figure
- …