502 research outputs found

    Peer Sexual Harassment: Holding Educational Institutions to a Higher Standard

    Get PDF

    Real-world clinical experience in the Connect® chronic lymphocytic leukaemia registry: a prospective cohort study of 1494 patients across 199 US centres.

    Get PDF
    The clinical course of chronic lymphocytic leukaemia (CLL) is heterogeneous, and treatment options vary considerably. The Connect® CLL registry is a multicentre, prospective observational cohort study that provides a real-world perspective on the management of, and outcomes for, patients with CLL. Between 2010 and 2014, 1494 patients with CLL and that initiated therapy, were enrolled from 199 centres throughout the USA (179 community-, 17 academic-, and 3 government-based centres). Patients were grouped by line of therapy at enrolment (LOT). We describe the clinical and demographic characteristics of, and practice patterns for, patients with CLL enrolled in this treatment registry, providing patient-level observational data that represent real-world experiences in the USA. Fluorescence in situ hybridization (FISH) analyses were performed on 49·3% of patients at enrolment. The most common genetic abnormalities detected by FISH were del(13q) and trisomy 12 (45·7% and 20·8%, respectively). Differences in disease characteristics and comorbidities were observed between patients enrolled in LOT1 and combined LOT2/≥3 cohorts. Important trends observed include the infrequent use of genetic prognostic testing, and differences in patient characteristics for patients receiving chemoimmunotherapy combinations. These data represent experiences of patients with CLL in the USA, which may inform treatment decisions in everyday practice

    Treatment of fecal impaction in children using combined polyethylene glycol and sodium picosulphate

    Get PDF
    Background and Aim: Polyethylene glycol (PEG) is the gold standard for fecal disimpaction in constipation. A regimen of PEG combined with the stimulant laxative sodium picosulphate (SPS) produced fecal disimpaction in chronically constipated children in the community, but it is unknown if it is effective for more severe constipation. To determine the stool output and effect of a combined PEG and SPS regimen on fecaloma in children with severe constipation and impaction. Methods: Children with symptoms for a duration of >= 2 years, a palpable fecaloma, and enlarged rectum on X-ray (rectal: pelvic ratio > 0.6) were recruited from a tertiary hospital. Daily diaries recorded laxative dose, stool frequency, volume, and consistency (Bristol stool scale, BSS). Abdominal X-rays were taken on day 1 and day 8, and stool loading was assessed using the Leech score. Laxative doses were based on the child's age. The dose of PEG with electrolytes taken was 2-8 sachets (14.7 g/sachet) on days 1-2, reducing to 2-6 sachets on day 3. The SPS dose was 15-20 drops on days 2-3. Results: Eighty-nine children (4-18 years) produced a large volume of soft stool (median/inter-quartile-range: 2.2/1.6-3.1 L) over 7 days. Stool volume on X-rays decreased significantly in the colon (P <0.001). Fecalomas resolved in 40 of 89 children, while 49 needed a second high dose. Rectal: pelvic ratios did not change. Conclusions: A combined high dose of PEG and SPS on days 1 and 2 was effective in removing the fecaloma in half of the children. Administering high doses for a longer period should be tested to provide outpatient disimpaction for severe fecalomas. Rectums remained flaccid after emptying

    2-Hour Accelerated Diagnostic Protocol to Assess Patients With Chest Pain Symptoms Using Contemporary Troponins as the Only Biomarker

    Get PDF
    Objectives The purpose of this study was to determine whether a new accelerated diagnostic protocol (ADP) for possible cardiac chest pain could identify low-risk patients suitable for early discharge (with follow-up shortly after discharge). Background Patients presenting with possible acute coronary syndrome (ACS), who have a low short-term risk of adverse cardiac events may be suitable for early discharge and shorter hospital stays. Methods This prospective observational study tested an ADP that included pre-test probability scoring by the Thrombolysis In Myocardial Infarction (TIMI) score, electrocardiography, and 0 + 2 h values of laboratory troponin I as the sole biomarker. Patients presenting with chest pain due to suspected ACS were included. The primary endpoint was major adverse cardiac event (MACE) within 30 days. Results Of 1,975 patients, 302 (15.3%) had a MACE. The ADP classified 392 patients (20%) as low risk. One (0.25%) of these patients had a MACE, giving the ADP a sensitivity of 99.7% (95% confidence interval [CI]: 98.1% to 99.9%), negative predictive value of 99.7% (95% CI: 98.6% to 100.0%), specificity of 23.4% (95% CI: 21.4% to 25.4%), and positive predictive value of 19.0% (95% CI: 17.2% to 21.0%). Many ADP negative patients had further investigations (74.1%), and therapeutic (18.3%) or procedural (2.0%) interventions during the initial hospital attendance and/or 30-day follow-up. Conclusions Using the ADP, a large group of patients was successfully identified as at low short-term risk of a MACE and therefore suitable for rapid discharge from the emergency department with early follow-up. This approach could decrease the observation period required for some patients with chest pain. (An observational study of the diagnostic utility of an accelerated diagnostic protocol using contemporary central laboratory cardiac troponin in the assessment of patients presenting to two Australasian hospitals with chest pain of possible cardiac origin; ACTRN12611001069943

    The Deuteron Spin-dependent Structure Function g1d and its First Moment

    Get PDF
    We present a measurement of the deuteron spin-dependent structure function g1d based on the data collected by the COMPASS experiment at CERN during the years 2002-2004. The data provide an accurate evaluation for Gamma_1^d, the first moment of g1d(x), and for the matrix element of the singlet axial current, a0. The results of QCD fits in the next to leading order (NLO) on all g1 deep inelastic scattering data are also presented. They provide two solutions with the gluon spin distribution function Delta G positive or negative, which describe the data equally well. In both cases, at Q^2 = 3 (GeV/c)^2 the first moment of Delta G is found to be of the order of 0.2 - 0.3 in absolute value.Comment: fits redone using MRST2004 instead of MRSV1998 for G(x), correlation matrix adde

    Spin Structure of the Proton from Polarized Inclusive Deep-Inelastic Muon-Proton Scattering

    Get PDF
    We have measured the spin-dependent structure function g1pg_1^p in inclusive deep-inelastic scattering of polarized muons off polarized protons, in the kinematic range 0.003<x<0.70.003 < x < 0.7 and 1GeV2<Q2<60GeV21 GeV^2 < Q^2 < 60 GeV^2. A next-to-leading order QCD analysis is used to evolve the measured g1p(x,Q2)g_1^p(x,Q^2) to a fixed Q02Q^2_0. The first moment of g1pg_1^p at Q02=10GeV2Q^2_0 = 10 GeV^2 is Γp=0.136±0.013(stat.)±0.009(syst.)±0.005(evol.)\Gamma^p = 0.136\pm 0.013(stat.) \pm 0.009(syst.)\pm 0.005(evol.). This result is below the prediction of the Ellis-Jaffe sum rule by more than two standard deviations. The singlet axial charge a0a_0 is found to be 0.28±0.160.28 \pm 0.16. In the Adler-Bardeen factorization scheme, Δg2\Delta g \simeq 2 is required to bring ΔΣ\Delta \Sigma in agreement with the Quark-Parton Model. A combined analysis of all available proton and deuteron data confirms the Bjorken sum rule.Comment: 33 pages, 22 figures, uses ReVTex and smc.sty. submitted to Physical Review

    Gluon polarization in the nucleon from quasi-real photoproduction of high-pT hadron pairs

    Get PDF
    We present a determination of the gluon polarization Delta G/G in the nucleon, based on the helicity asymmetry of quasi-real photoproduction events, Q^2<1(GeV/c)^2, with a pair of large transverse-momentum hadrons in the final state. The data were obtained by the COMPASS experiment at CERN using a 160 GeV polarized muon beam scattered on a polarized 6-LiD target. The helicity asymmetry for the selected events is = 0.002 +- 0.019(stat.) +- 0.003(syst.). From this value, we obtain in a leading-order QCD analysis Delta G/G=0.024 +- 0.089(stat.) +- 0.057(syst.) at x_g = 0.095 and mu^2 =~ 3 (GeV}/c)^2.Comment: 10 pages, 3 figure

    Measurement of the Spin Structure of the Deuteron in the DIS Region

    Full text link
    We present a new measurement of the longitudinal spin asymmetry A_1^d and the spin-dependent structure function g_1^d of the deuteron in the range 1 GeV^2 < Q^2 < 100 GeV^2 and 0.004< x <0.7. The data were obtained by the COMPASS experiment at CERN using a 160 GeV polarised muon beam and a large polarised 6-LiD target. The results are in agreement with those from previous experiments and improve considerably the statistical accuracy in the region 0.004 < x < 0.03.Comment: 10 pages, 6 figures, subm. to PLB, revised: author list, Fig. 4, details adde

    Spin asymmetry A_1^d and the spin-dependent structure function g_1^d of the deuteron at low values of x and Q^2

    Get PDF
    We present a precise measurement of the deuteron longitudinal spin asymmetry A_1^d and of the deuteron spin-dependent structure function g_1^d at Q^2 < 1 GeV^2 and 4*10^-5 < x < 2.5*10^-2 based on the data collected by the COMPASS experiment at CERN during the years 2002 and 2003. The statistical precision is tenfold better than that of the previous measurement in this region. The measured A_1^d and g_1^d are found to be consistent with zero in the whole range of x.Comment: 17 pages, 10 figure
    corecore