326 research outputs found

    Centaur 1956

    Get PDF
    Digitised by the Faculty of the Veterinary Scienc

    Risk of coronary stenosis after adjuvant radiotherapy for breast cancer

    Get PDF
    Purpose Adjuvant radiotherapy (RT) for breast cancer is associated with an increased risk of ischemic heart disease. We examined the risk of coronary artery stenosis in a large cohort of women with breast cancer receiving adjuvant RT. Methods A cohort of women diagnosed with breast cancer between 1992 and 2012 in three Swedish health care regions (n = 57,066) were linked to the Swedish Coronary Angiography and Angioplasty Registry (SCAAR) to identify women receiving RT who subsequently underwent a percutaneous coronary intervention (PCI) due to coronary stenosis. Cox regression analyses were performed to examine risk of a coronary intervention and competing risk analyses were performed to calculate cumulative incidence. Results A total of 649 women with left-sided breast cancer and 494 women with right-sided breast cancer underwent a PCI. Women who received left-sided RT had a significantly higher risk of a PCI in the left anterior descending artery (LAD) compared to women who received right-sided RT, hazard ratio (HR) 1.44 (95% confidence interval [CI] 1.21-1.77, p < 0.001). For the proximal, mid, and distal LAD, the HRs were 1.60 (95% CI 1.22-2.10), 1.38 (95% CI 1.07-1.78), and 2.43 (95% CI 1.33-4.41), respectively. The cumulative incidence of coronary events at 25 years from breast cancer diagnosis were 7.0% in women receiving left-sided RT and 4.4% in women receiving right-sided RT. Conclusion Implementing and further developing techniques that lower cardiac doses is important in order to reduce the risk of long-term side effects of adjuvant RT for breast cancer.Peer reviewe

    DNA nucleotide-specific modulation of \mu A transverse edge currents through a metallic graphene nanoribbon with a nanopore

    Full text link
    We propose two-terminal devices for DNA sequencing which consist of a metallic graphene nanoribbon with zigzag edges (ZGNR) and a nanopore in its interior through which the DNA molecule is translocated. Using the nonequilibrium Green functions combined with density functional theory, we demonstrate that each of the four DNA nucleotides inserted into the nanopore, whose edge carbon atoms are passivated by either hydrogen or nitrogen, will lead to a unique change in the device conductance. Unlike other recent biosensors based on transverse electronic transport through DNA nucleotides, which utilize small (of the order of pA) tunneling current across a nanogap or a nanopore yielding a poor signal-to-noise ratio, our device concept relies on the fact that in ZGNRs local current density is peaked around the edges so that drilling a nanopore away from the edges will not diminish the conductance. Inserting a DNA nucleotide into the nanopore affects the charge density in the surrounding area, thereby modulating edge conduction currents whose magnitude is of the order of \mu A at bias voltage ~ 0.1 V. The proposed biosensor is not limited to ZGNRs and it could be realized with other nanowires supporting transverse edge currents, such as chiral GNRs or wires made of two-dimensional topological insulators.Comment: 6 pages, 6 figures, PDFLaTe

    Drivers for Rift Valley fever emergence in Mayotte: A Bayesian modelling approach

    Get PDF
    Rift Valley fever (RVF) is a major zoonotic and arboviral hemorrhagic fever. The conditions leading to RVF epidemics are still unclear, and the relative role of climatic and anthropogenic factors may vary between ecosystems. Here, we estimate the most likely scenario that led to RVF emergence on the island of Mayotte, following the 2006–2007 African epidemic. We developed the first mathematical model for RVF that accounts for climate, animal imports and livestock susceptibility, which is fitted to a 12-years dataset. RVF emergence was found to be triggered by the import of infectious animals, whilst transmissibility was approximated as a linear or exponential function of vegetation density. Model forecasts indicated a very low probability of virus endemicity in 2017, and therefore of re-emergence in a closed system (i.e. without import of infected animals). However, the very high proportion of naive animals reached in 2016 implies that the island remains vulnerable to the import of infectious animals. We recommend reinforcing surveillance in livestock, should RVF be reported is neighbouring territories. Our model should be tested elsewhere, with ecosystem-specific data

    Transverse Electronic Transport through DNA Nucleotides with Functionalized Graphene Electrodes

    Full text link
    Graphene nanogaps and nanopores show potential for the purpose of electrical DNA sequencing, in particular because single-base resolution appears to be readily achievable. Here, we evaluated from first principles the advantages of a nanogap setup with functionalized graphene edges. To this end, we employed density functional theory and the non-equilibrium Green's function method to investigate the transverse conductance properties of the four nucleotides occurring in DNA when located between the opposing functionalized graphene electrodes. In particular, we determined the electrical tunneling current variation as a function of the applied bias and the associated differential conductance at a voltage which appears suitable to distinguish between the four nucleotides. Intriguingly, we observe for one of the nucleotides a negative differential resistance effect.Comment: 19 pages, 7 figure

    Current-Induced Effects in Nanoscale Conductors

    Full text link
    We present an overview of current-induced effects in nanoscale conductors with emphasis on their description at the atomic level. In particular, we discuss steady-state current fluctuations, current-induced forces, inelastic scattering and local heating. All of these properties are calculated in terms of single-particle wavefunctions computed using a scattering approach within the static density-functional theory of many-electron systems. Examples of current-induced effects in atomic and molecular wires will be given and comparison with experimental results will be provided when available.Comment: revtex, 10 pages, 8 figure

    Thrombus aspiration during ST-segment elevation myocardial infarction.

    Get PDF
    To access publisher's full text version of this article. Please click on the hyperlink in Additional Links field.The clinical effect of routine intracoronary thrombus aspiration before primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI) is uncertain. We aimed to evaluate whether thrombus aspiration reduces mortality.We conducted a multicenter, prospective, randomized, controlled, open-label clinical trial, with enrollment of patients from the national comprehensive Swedish Coronary Angiography and Angioplasty Registry (SCAAR) and end points evaluated through national registries. A total of 7244 patients with STEMI undergoing PCI were randomly assigned to manual thrombus aspiration followed by PCI or to PCI only. The primary end point was all-cause mortality at 30 days.No patients were lost to follow-up. Death from any cause occurred in 2.8% of the patients in the thrombus-aspiration group (103 of 3621), as compared with 3.0% in the PCI-only group (110 of 3623) (hazard ratio, 0.94; 95% confidence interval [CI], 0.72 to 1.22; P=0.63). The rates of hospitalization for recurrent myocardial infarction at 30 days were 0.5% and 0.9% in the two groups, respectively (hazard ratio, 0.61; 95% CI, 0.34 to 1.07; P=0.09), and the rates of stent thrombosis were 0.2% and 0.5%, respectively (hazard ratio, 0.47; 95% CI, 0.20 to 1.02; P=0.06). There were no significant differences between the groups with respect to the rate of stroke or neurologic complications at the time of discharge (P=0.87). The results were consistent across all major prespecified subgroups, including subgroups defined according to thrombus burden and coronary flow before PCI.Routine thrombus aspiration before PCI as compared with PCI alone did not reduce 30-day mortality among patients with STEMI. (Funded by the Swedish Research Council and others; ClinicalTrials.gov number, NCT01093404.).Swedish Research Council, Swedish Association of Local Authorities and Regions, Terumo Medical Corporation, Medtronic, Vascular Solutions, Swedish Heart-Lung Foundation/20100178/ B0010401 Biotronik, Stentys, Abbott Vascular, St. Jude Medical, Boston Scientific, EPS Vascular, Cardiac Dimensions, AstraZeneca, Edwards Lifesciences

    Transverse electric field dragging of DNA in a nanochannel

    Get PDF
    Nanopore analysis is an emerging single-molecule strategy for non-optical and high-throughput DNA sequencing, the principle of which is based on identification of each constituent nucleobase by measuring trans-membrane ionic current blockade or transverse tunnelling current as it moves through the pore. A crucial issue for nanopore sequencing is the fact that DNA translocates a nanopore too fast for addressing sequence with a single base resolution. Here we report that a transverse electric field can be used to slow down the translocation. We find 400-fold decrease in the DNA translocation speed by adding a transverse field of 10 mV/nm in a gold-electrode-embedded silicon dioxide channel. The retarded flow allowed us to map the local folding pattern in individual DNA from trans-pore ionic current profiles. This field dragging approach may provide a new way to control the polynucleotide translocation kinetics

    Single-molecule sensing electrode embedded in-plane nanopore

    Get PDF
    Electrode-embedded nanopore is considered as a promising device structure for label-free single-molecule sequencing, the principle of which is based on nucleotide identification via transverse electron tunnelling current flowing through a DNA translocating through the pore. Yet, fabrication of a molecular-scale electrode-nanopore detector has been a formidable task that requires atomic-level alignment of a few nanometer sized pore and an electrode gap. Here, we report single-molecule detection using a nucleotide-sized sensing electrode embedded in-plane nanopore. We developed a self-alignment technique to form a nanopore-nanoelectrode solid-state device consisting of a sub-nanometer scale electrode gap in a 15 nm-sized SiO2 pore. We demonstrate single-molecule counting of nucleotide-sized metal-encapsulated fullerenes in a liquid using the electrode-integrated nanopore sensor. We also performed electrical identification of nucleobases in a DNA oligomer, thereby suggesting the potential use of this synthetic electrode-in-nanopore as a platform for electrical DNA sequencing

    Reporting of harm in randomized controlled trials evaluating stents for percutaneous coronary intervention

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to assess the reporting of harm in randomized controlled trials evaluating stents for percutaneous coronary intervention.</p> <p>Methods</p> <p>The study design was a methodological systematic review of randomized controlled trials. The data sources were MEDLINE and the Cochrane Central Register of Controlled Trials. All reports of randomized controlled trials assessing stent treatment for coronary disease published between January 1, 2003, and September 30, 2008 were selected.</p> <p>A standardized abstraction form was used to extract data.</p> <p>Results</p> <p>132 articles were analyzed. Major cardiac adverse events (death, cardiac death, myocardial infarction or stroke) were reported as primary or secondary outcomes in 107 reports (81%). However, 19% of the articles contained no data on cardiac events. The mode of data collection of adverse events was given in 29 reports (22%) and a definition of expected adverse events was provided in 47 (36%). The length of follow-up was reported in 95 reports (72%). Assessment of adverse events by an adjudication committee was described in 46 reports (35%), and adverse events were described as being followed up for 6 months in 24% of reports (n = 32), between 7 to 12 months in 42% (n = 55) and for more than 1 year in 4% (n = 5). In 115 reports (87%), numerical data on the nature of the adverse events were reported per treatment arm. Procedural complications were described in 30 articles (23%). The causality of adverse events was reported in only 4 articles.</p> <p>Conclusion</p> <p>Several harm-related data were not adequately accounted for in articles of randomized controlled trials assessing stents for percutaneous coronary intervention.</p> <p>Trials Registration</p> <p>Trials manuscript: 5534201182098351 (T80802P)</p
    • …
    corecore