1,813 research outputs found

    Surgical treatment of complete penile duplication

    Get PDF
    Penile duplication is a rare anomaly with an incidence of 1 in 5,500,000. It is almost associated with other malformations like double bladder, presence of the cloaca, imperforate anus, duplication of the recto sigmoid and vertebral deformities. The authors present the surgical technique to resolve a rare case of complete penile duplication in a 4 years old child, without any other malformation

    Hemodynamic responses of unfit healthy women at a training session with Nintendo wii: a possible Impact on the general well-being

    Get PDF
    Aims: The purpose of this study was assess the effect of a training session with Nintendo Wii® on the hemody- namic responses of healthy women not involved in regular physical exercise. Method: Twenty-five healthy unfit women aged 28 ± 6 years played for 10 minutes the game Free Run (Wii Fit Plus). The resting heart rate (RHR), systolic and dia- stolic blood pressures (SBP and DBP), and double (rate-pressure) product (DP) were measured before and after activity. The HR during the activity (exercise heart rate, EHR) was measured every minute. Results: A statistically significant dif- ference was observed between the RHR (75 ± 9 bpm) and the mean EHR (176 ± 15 bpm) (P < 0.001). The EHR remained in the target zone for aerobic exercise until the fifth minute of activity, which coincided with the upper limit of the aerobic zone (80% heart rate reserve (HRR) + RHR) from the sixth to tenth minute. The initial (110 ± 8 mmHg) and final (145 ± 17 mmHg) SBP (P < 0.01) were significantly different, as were the initial (71 ± 8 mmHg) and final (79 ± 9 mmHg) DBP (P < 0.01). A statistically significant difference was observed between the pre- (8.233 ± 1.141 bpm-mmHg) and post- activity (25.590 ± 4.117 bpm-mmHg) DP (P < 0.01). Conclusion: Physical exercise while playing Free Run sufficed to trigger acute hemodynamic changes in healthy women who were not engaged in regular physical exercis

    Pleuroamniotic shunting--case report

    Get PDF
    Fetal hydrothorax refers to a collection of fluid within the fetal thorax that may be the result of chylous leak from the thoracic duct (primary hydrothorax) or generalized fluid retention associated with immune or no immune fetal hydrops (secondary hydrothorax). The authors' presents a case report occurred in 2002, of a pregnant woman that at 25 weeks' gestation that was referred to Maternidade Bissaya-Barreto-Coimbra because of a fetal hydrothorax at left, under tension and with cardiac decompensation signs. A fetal thoracocentesis was performed and the diagnosis was chylothorax. Because of a rapid reaccumulation of fluid a pleuroamniotic shunt was placed. The effusion and the cardiac decompensation signs regressed. The delivery was at 38 weeks' gestation. The newborn had been stable. Actually he has 10 months, is healthy and has a normal grow and development

    Eleven fetal echocardiographic planes using 4-dimensional ultrasound with spatio-temporal image correlation (STIC): a logical approach to fetal heart volume analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Theoretically, a cross-sectional image of any cardiac planes can be obtained from a STIC fetal heart volume dataset. We described a method to display 11 fetal echocardiographic planes from STIC volumes.</p> <p>Methods</p> <p>Fetal heart volume datasets were acquired by transverse acquisition from 200 normal fetuses at 15 to 40 weeks of gestation. Analysis of the volume datasets using the described technique to display 11 echocardiographic planes in the multiplanar display mode were performed offline.</p> <p>Results</p> <p>Volume datasets from 18 fetuses were excluded due to poor image resolution. The mean visualization rates for all echocardiographic planes at 15-17, 18-22, 23-27, 28-32 and 33-40 weeks of gestation fetuses were 85.6% (range 45.2-96.8%, N = 31), 92.9% (range 64.0-100%, N = 64), 93.4% (range 51.4-100%, N = 37), 88.7%(range 54.5-100%, N = 33) and 81.8% (range 23.5-100%, N = 17) respectively.</p> <p>Conclusions</p> <p>Overall, the applied technique can favorably display the pertinent echocardiographic planes. Description of the presented method provides a logical approach to explore the fetal heart volumes.</p

    Detection of mosaic and population-level structural variants with Sniffles2

    Get PDF
    Calling structural variations (SVs) is technically challenging, but using long reads remains the most accurate way to identify complex genomic alterations. Here we present Sniffles2, which improves over current methods by implementing a repeat aware clustering coupled with a fast consensus sequence and coverage-adaptive filtering. Sniffles2 is 11.8 times faster and 29% more accurate than state-of-the-art SV callers across different coverages (5–50×), sequencing technologies (ONT and HiFi) and SV types. Furthermore, Sniffles2 solves the problem of family-level to population-level SV calling to produce fully genotyped VCF files. Across 11 probands, we accurately identified causative SVs around MECP2, including highly complex alleles with three overlapping SVs. Sniffles2 also enables the detection of mosaic SVs in bulk long-read data. As a result, we identified multiple mosaic SVs in brain tissue from a patient with multiple system atrophy. The identified SV showed a remarkable diversity within the cingulate cortex, impacting both genes involved in neuron function and repetitive elements

    Spin polarization of carriers in InGaAs self-assembled quantum rings inserted in GaAs-AlGaAs resonant tunneling devices

    Get PDF
    In this work, we have investigated transport and polarization resolved photoluminescence (PL) of n-type GaAs-AlGaAs resonant tunneling diodes (RTDs) containing a layer of InGaAs self-assembled quantum rings (QRs) in the quantum well (QW). All measurements were performed under applied voltage, magnetic fields up to 15 T and using linearly polarized laser excitation. It was observed that the QRs’ PL intensity and the circular polarization degree (CPD) oscillate periodically with applied voltage under high magnetic fields at 2 K. Our results demonstrate an effective voltage control of the optical and spin properties of InGaAs QRs inserted into RTDs
    corecore