26 research outputs found

    The main actors involved in parasitization of Heliothis virescens larva

    Get PDF
    At the moment of parasitization by another insect, the host Heliothis larva is able to defend itself by the activation of humoral and cellular defenses characterized by unusual reactions of hemocytes in response to external stimuli. Here, we have combined light and electron microscopy, staining reactions, and immunocytochemical characterization to analyze the activation and deactivation of one of the most important immune responses involved in invertebrates defense, i.e., melanin production and deposition. The insect host/parasitoid system is a good model to study these events. The activated granulocytes of the host insect are a major repository of amyloid fibrils forming a lattice in the cell. Subsequently, the exocytosed amyloid lattice constitutes the template for melanin deposition in the hemocel. Furthermore, cross-talk between immune and neuroendocrine systems mediated by hormones, cytokines, and neuromodulators with the activation of stress-sensoring circuits to produce and release molecules such as adrenocorticotropin hormone, alpha melanocyte-stimulating hormone, and neutral endopeptidase occurs. Thus, parasitization promotes massive morphological and physiological modifications in the host insect hemocytes and mimics general stress conditions in which phenomena such as amyloid fibril formation, melanin polymerization, pro-inflammatory cytokine production, and activation of the adrenocorticotropin hormone system occur. These events observed in invertebrates are also reported in the literature for vertebrates, suggesting that this network of mechanisms and responses is maintained throughout evolution

    Clinical efficacy and effectiveness of 3D printing: a systematic review.

    No full text
    Objective To evaluate the clinical efficacy and effectiveness of using 3D printing to develop medical devices across all medical fields. Design Systematic review compliant with Preferred Reporting Items for Systematic Reviews and Meta-Analyses. Data sources PubMed, Web of Science, OVID, IEEE Xplore and Google Scholar. Methods double-blinded review method was used to select all abstracts up to January 2017 that reported on clinical trials of a three-dimensional (3D)-printed medical device. The studies were ranked according to their level of evidence, divided into medical fields based on the International Classification of Diseases chapter divisions and categorised into whether they were used for preoperative planning, aiding surgery or therapy. The Downs and Black Quality Index critical appraisal tool was used to assess the quality of reporting, external validity, risk of bias, risk of confounding and power of each study. Results Of the 3084 abstracts screened, 350 studies met the inclusion criteria. Oral and maxillofacial surgery contained 58.3% of studies, and 23.7% covered the musculoskeletal system. Only 21 studies were randomised controlled trials (RCTs), and all fitted within these two fields. The majority of RCTs were 3D-printed anatomical models for preoperative planning and guides for aiding surgery. The main benefits of these devices were decreased surgical operation times and increased surgical accuracy. Conclusions All medical fields that assessed 3D-printed devices concluded that they were clinically effective. The fields that most rigorously assessed 3D-printed devices were oral and maxillofacial surgery and the musculoskeletal system, both of which concluded that the 3D-printed devices outperformed their conventional comparators. However, the efficacy and effectiveness of 3D-printed devices remain undetermined for the majority of medical fields. 3D-printed devices can play an important role in healthcare, but more rigorous and long-term assessments are needed to determine if 3D-printed devices are clinically relevant before they become part of standard clinical practice.</p

    Comparing thermal discomfort with skin temperature response of lower-limb prosthesis users during exercise

    No full text
    Background Thermal discomfort is prevalent among prosthesis users. This observational study of thirty unilateral lower-limb prosthesis users compared their skin temperatures and the thermal discomfort experienced during exercise between their residual and contralateral limbs. Methods Participants performed a 2-minute interval cycling exercise test. Skin temperature was measured at matched locations on each leg during the 1-minute rest intervals. Average rate-of-change in skin temperature was compared between legs using a repeated measures analysis of variance. Participants rated thermal discomfort on each leg before and after exercise, and a Wilcoxon signed-rank test was used to compare legs. Ordinal regression evaluated the relationship between the rate-of-change in temperature on the residual limb and the perceived thermal discomfort. Findings After exercise, thermal discomfort ranked higher on the amputated side (P = 0.007). On average, both legs cooled during exercise (P = 0.002), but the difference between legs was not significant. The rate-of change in skin temperature on the residual limb during exercise did not relate to the thermal discomfort experienced (odds ratio of 0.357). Interpretation These findings indicate that in this patient population, skin temperature does not explain the thermal discomfort experienced, and subjective thermal discomfort is inadequate for detecting thermoregulatory issues, with potential implications for long-term tissue health

    Comparing thermal discomfort with skin temperature response of lower-limb prosthesis users during exercise

    No full text
    Background Thermal discomfort is prevalent among prosthesis users. This observational study of thirty unilateral lower-limb prosthesis users compared their skin temperatures and the thermal discomfort experienced during exercise between their residual and contralateral limbs. Methods Participants performed a 2-minute interval cycling exercise test. Skin temperature was measured at matched locations on each leg during the 1-minute rest intervals. Average rate-of-change in skin temperature was compared between legs using a repeated measures analysis of variance. Participants rated thermal discomfort on each leg before and after exercise, and a Wilcoxon signed-rank test was used to compare legs. Ordinal regression evaluated the relationship between the rate-of-change in temperature on the residual limb and the perceived thermal discomfort. Findings After exercise, thermal discomfort ranked higher on the amputated side (P = 0.007). On average, both legs cooled during exercise (P = 0.002), but the difference between legs was not significant. The rate-of change in skin temperature on the residual limb during exercise did not relate to the thermal discomfort experienced (odds ratio of 0.357). Interpretation These findings indicate that in this patient population, skin temperature does not explain the thermal discomfort experienced, and subjective thermal discomfort is inadequate for detecting thermoregulatory issues, with potential implications for long-term tissue health

    Etude de la trajectographie des chutes de blocs en forĂŞts de montagne

    No full text
    National audienceL'évaluation du rôle protecteur de la forêt contre les chutes de blocs rocheux nécessite un outil de simulation numérique, afin de modéliser les collisions entre un bloc rocheux et le sol ainsi que les collisions d'un bloc rocheux avec un arbre. Le moteur de calcul STAR3D, développé au LCPC, est un outil adapté à ce type de calculs trajectographiques. Les éléments théoriques utilisés par le programme font apparaître des paramètres qu'il convient d'identifier par des expériences en vraie grandeur. Les expériences réalisées par le cemagref de Grenoble sur le site de Vaujany ont permis d'identifier certains de ces paramètres, les autres provenant de la littérature,µ. Tous les paramètres étant déterminés, des simulations numériques ont été réalisées avec STAR3D qui est actuellement le seul outil de calcul trajectographique permettant de réaliser ces calculs. Les résultats obtenus pour les hauteurs de passage, les énergies et les points d'arrêt des blocs correspondent très bien aux valeurs mesurées lors des lâchers expérimentaux de blocs
    corecore