240 research outputs found

    Integration of data from remote monitoring systems and programmers into the hospital electronic health record system based on international standards

    Get PDF
    Remote follow-up of implanted ICDs may offer a solution to the problem of overcrowded outpatient clinics. All major device companies have developed a remote follow-up solution. Data obtained from the remote follow-up systems are stored in a central database system, operated and owned by the device company and accessible for the physician or technician. However, the problem now arises that part of the patient’s clinical information is stored in the local electronic health record (EHR) system in the hospital, while another part is only available in the remote monitoring database. This may potentially result in patient safety issues. Ideally all information should become available in the EHR system. IHE (Integrating the Healthcare Enterprise) is an initiative to improve the way computer systems in healthcare share information. To address the requirement of integrating remote monitoring data in the local EHR, the IHE Implantable Device Cardiac Observation (IDCO) profile has been developed. In our hospital, we have implemented the IHE IDCO profile to import data from the remote databases from two device vendors into the departmental Cardiology Information System. Data are exchanged via an HL7/XML communication protocol, as defined in the IHE IDCO profile

    Fusion cardiac resynchronization therapy in an left ventricular assist device patient from two devices and crossing leads: a case report

    Get PDF
    Background Cardiac implanted electronic devices (CIED) have significantly improved the survival and quality of life in heart failure patients. Although implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy (CRT) have a major role in patients with moderate to severe heart failure symptoms, the role of these devices in patients with a left ventricular assist device (LVAD) is not yet well defined. The burden of CIED-related procedures in patients with an LVAD is high. The price of lead malfunctions and pocket complications requires creative approaches to tackle CIED-related issues in this patient population.Case summary Here, we describe the clinical course of a 67-year-old ventricular pacing dependent LVAD patient with an ICD indication based on recurrent monomorphic ventricular tachycardias and a CRT indication due to previous deterioration of (right-sided) heart failure in the absence of biventricular pacing. We were confronted with impending right ventricular lead failure and bilateral venous access problems due to chronic subclavian vein occlusion in a patient with a total of five transvenous leads, therapeutic anticoagulation, and pronounced thoracic collaterals. We sought for a creative solution to be able to deliver effective biventricular fusion pacing with the existing leads from two contralateral pulse generators resulting in biventricular fusion pacing. This provided the solution to deliver effective CRT.Discussion This case illustrates the complexity of care and CIED-related decision-making in pacing dependent LVAD patients, in particularly those with an ICD and CRT indication.Cardiolog

    Failing systemic right ventricle in a patient with dextrocardia and complex congenitally corrected transposition of the great arteries: a case report of successful transvenous cardiac resynchronization therapy

    Get PDF
    Background Patients with congenitally corrected transposition of the great arteries (ccTGA) are prone to the development of advanced atrio-ventricular block requiring chronic ventricular pacing. The morphological right ventricle (RV) often develops systolic dysfunction as it is unable to withstand the chronic pressure overload it is exposed to when supporting the systemic circulation.Case summary A 56-year-old woman with dextrocardia and complex ccTGA with a history of dual-chamber implantable cardioverter-defibrillator (DDD-ICD, high degree atrio-ventricular-block and syncopal ventricular tachycardia), presented with progressive heart failure and symptomatic atrial arrhythmias. She underwent a successful ablation and concomitant invasive haemodynamic evaluation of potential alternative/biventricular pacing modalities. During biventricular pacing, the QRS narrowed and the systemic RV intraventricular pressure (Dp/Dt) increased with 30%. She underwent a successful transvenous upgrade to cardiac resynchronization therapy (CRT). The electrocardiogram post-implantation showed biventricular capture and patient showed subjective and objective clinical improvement.Discussion Systemic RV dysfunction in ccTGA can be aggravated by chronic pacing-induced dyssynchrony, contributing to progression of heart failure in this patient group. Transvenous CRT is feasible in ccTGA anatomy and may be pursued in order to improve or preserve the functional status of pacing-dependent ccTGA patients. Invasive haemodynamic contractility evaluation can help assess the potential benefit of CRT in patients with complex anatomy.Cardiolog

    Recurrence of ventricular arrhythmias in ischaemic secondary prevention implantable cardioverter defibrillator recipients: long-term follow-up of the Leiden out-of-hospital cardiac arrest study (LOHCAT)

    Get PDF
    Aims to assess the long-term rate of mortality and the recurrence of potentially life-threatening ventricular arrhythmias in secondary prevention implantable cardioverter defibrillator (ICD) patients and to construct a model for baseline risk stratification.Methods and resultsSince 1996, all patients with ischaemic heart disease, receiving ICD therapy for secondary prevention of sudden death, were included in the current study. Patients were evaluated at implantation and during long-term follow-up. A total of 456 patients were included in the analysis and followed for 54 ± 35 months. During follow-up, 100 (22) patients died and ICD therapy was noted in 216 (47) patients, of which 138 (30) for fast, potentially life-threatening ventricular arrhythmia. Multivariate analysis revealed a history of atrial fibrillation or flutter (AF), ventricular tachycardia as presenting arrhythmia, and wide QRS and poor left ventricular ejection fraction as independent predictors of life-threatening ventricular arrhythmias. The strongest predictor was AF with a hazard ratio of 2.1 (95 confidence interval 1.3-3.2). On the basis of the available clinical data, it was not possible to identify a group which exhibited no risk on recurrence of potentially life-threatening ventricular arrhythmias.ConclusionIschaemic secondary prevention ICD recipients exhibit a high recurrence rate of potentially life-threatening ventricular arrhythmias. Factors that increase risk can be identified but, even with these factors, it was not possible to distinguish a recurrence-free group

    Some Properties of R\'{e}nyi Entropy over Countably Infinite Alphabets

    Full text link
    In this paper we study certain properties of R\'{e}nyi entropy functionals Hα(P)H_\alpha(\mathcal{P}) on the space of probability distributions over Z+\mathbb{Z}_+. Primarily, continuity and convergence issues are addressed. Some properties shown parallel those known in the finite alphabet case, while others illustrate a quite different behaviour of R\'enyi entropy in the infinite case. In particular, it is shown that, for any distribution P\mathcal P and any r[0,]r\in[0,\infty], there exists a sequence of distributions Pn\mathcal{P}_n converging to P\mathcal{P} with respect to the total variation distance, such that limnlimα1+Hα(Pn)=limα1+limnHα(Pn)+r\lim_{n\to\infty}\lim_{\alpha\to{1+}} H_\alpha(\mathcal{P}_n) = \lim_{\alpha\to{1+}}\lim_{n\to\infty} H_\alpha(\mathcal{P}_n) + r.Comment: 13 pages (single-column

    Forward K+ production in subthreshold pA collisions at 1.0 GeV

    Get PDF
    K+ meson production in pA (A = C, Cu, Au) collisions has been studied using the ANKE spectrometer at an internal target position of the COSY-Juelich accelerator. The complete momentum spectrum of kaons emitted at forward angles, theta < 12 degrees, has been measured for a beam energy of T(p)=1.0 GeV, far below the free NN threshold of 1.58 GeV. The spectrum does not follow a thermal distribution at low kaon momenta and the larger momenta reflect a high degree of collectivity in the target nucleus.Comment: 4 pages, 3 figure

    ‘Sell[ing] what hasn’t got a name’: An exploration of the different understandings and definitions of ‘community engagement’ work in the performing arts

    Get PDF
    Widely known to promote broader involvement in the processes which define the arts and culture (Webster, 1997), community engagement work in the performing arts — despite employing a set of commonly recognised norms — has tended to be conceptualised differently both historically and contemporarily. Drawing on ethnographic research — particularly semi-structured qualitative interview accounts of numerous British practitioners with a track record of work in the sector, the article explores these different conceptualisations. The article finds that it is the actual ‘work that matters’ and not what it is named, and that the diversity of understandings and definitions among sectoral practitioners is reflective of evolving thinking, values and practice, something that may be destabilising for better or worse

    Development and external validation of prediction models to predict implantable cardioverter-defibrillator efficacy in primary prevention of sudden cardiac death

    Get PDF
    Aims This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation.Methods and results We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality.Conclusion Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.Cardiolog

    Cryptographic Divergences: New Techniques and New Applications

    Get PDF
    In the recent years, some security proofs in cryptography have known significant improvements by replacing the statistical distance with alternative divergences. We continue this line of research, both at a theoretical and practical level. On the theory side, we propose a new cryptographic divergence with quirky properties. On the practical side, we propose new applications of alternative divergences: circuit-private FHE and prime number generators. More precisely, we provide the first formal security proof of the prime number generator PRIMEINC (Brandt and Damgård, CRYPTO 1992), and improve by an order of magnitude the efficiency of a prime number generator by Fouque and Tibouchi (ICALP 2014) and the washing machine technique by Ducas and Stehlé (EUROCRYPT 2016) for circuit-private FHE
    corecore