145 research outputs found

    Nanometer table-top proximity x-ray lithography with liquid-target laser-plasma source

    Get PDF
    A compact laser-plasma proximity x-ray lithography system suitable for laboratory-scale low-volume nanometer patterning is presented. The laser-plasma source, which is based on a fluorocarbon liquid-jet target, generates high-brightness lambda = 1.2-1.7 nm x-ray emission with only negligible debris production. The Au/SiNx x-ray mask is fabricated by employing ion milling and a high-contrast e-beam resist. With SAL-601 chemically enhanced resist we demonstrate fabrication of high-aspect-ratio, sub-100 nm structures. The exposure time is currently 20 min using a compact 10 Hz, lambda = 532 nm, 70 mJ/pulse mode-locked Nd:YAG laser. However, the regenerative liquid-jet target is designed for operation with future, e.g., 1000 Hz, lasers resulting in projected exposure times of similar to 10 s. (C) 1997 American Vacuum Society

    Light emission from a scanning tunneling microscope: Fully retarded calculation

    Full text link
    The light emission rate from a scanning tunneling microscope (STM) scanning a noble metal surface is calculated taking retardation effects into account. As in our previous, non-retarded theory [Johansson, Monreal, and Apell, Phys. Rev. B 42, 9210 (1990)], the STM tip is modeled by a sphere, and the dielectric properties of tip and sample are described by experimentally measured dielectric functions. The calculations are based on exact diffraction theory through the vector equivalent of the Kirchoff integral. The present results are qualitatively similar to those of the non-retarded calculations. The light emission spectra have pronounced resonance peaks due to the formation of a tip-induced plasmon mode localized to the cavity between the tip and the sample. At a quantitative level, the effects of retardation are rather small as long as the sample material is Au or Cu, and the tip consists of W or Ir. However, for Ag samples, in which the resistive losses are smaller, the inclusion of retardation effects in the calculation leads to larger changes: the resonance energy decreases by 0.2-0.3 eV, and the resonance broadens. These changes improve the agreement with experiment. For a Ag sample and an Ir tip, the quantum efficiency is ≈\approx 10−4^{-4} emitted photons in the visible frequency range per tunneling electron. A study of the energy dissipation into the tip and sample shows that in total about 1 % of the electrons undergo inelastic processes while tunneling.Comment: 16 pages, 10 figures (1 ps, 9 tex, automatically included); To appear in Phys. Rev. B (15 October 1998

    Ultrasensitive mass sensor fully integrated with complementary metal-oxide-semiconductor circuitry

    Get PDF
    Nanomechanical resonators have been monolithically integrated on preprocessed complementary metal-oxide-semiconductor(CMOS) chips. Fabricatedresonatorsystems have been designed to have resonance frequencies up to 1.5 MHz. The systems have been characterized in ambient air and vacuum conditions and display ultrasensitive mass detection in air. A mass sensitivity of 4ag/Hz has been determined in air by placing a single glycerine drop, having a measured weight of 57 fg, at the apex of a cantilever and subsequently measuring a frequency shift of 14.8 kHz. CMOS integration enables electrostatic excitation, capacitive detection, and amplification of the resonance signal directly on the chip

    Physicians' attitudes towards ePrescribing – evaluation of a Swedish full-scale implementation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The penetration rate of Electronic Health Record (EHR) systems in health care is increasing. However, many different EHR-systems are used with varying ePrescription designs and functionalities. The aim of the present study was to evaluate experienced ePrescribers' attitudes towards ePrescribing for suggesting improvements.</p> <p>Methods</p> <p>Physicians (n = 431) from seven out of the 21 Swedish health care regions, using one of the six most widely implemented EHR-systems with integrated electronic prescribing modules, were recruited from primary care centers and hospital clinics of internal medicine, orthopaedics and surgery. The physicians received a web survey that comprised eight questions on background data and 19 items covering attitudes towards ePrescribing. Forty-two percent (n = 199) of the physicians answered the questionnaire; 90% (n = 180) of the respondents met the inclusion criteria and were included in the final analysis.</p> <p>Results</p> <p>A majority of the respondents regarded their EHR-system easy to use in general (81%), and for the prescribing of drugs (88%). Most respondents believed they were able to provide the patients better service by ePrescribing (92%), and regarded ePrescriptions to be time saving (91%) and to be safer (83%), compared to handwritten prescriptions. Some of the most frequently reported weaknesses were: not clearly displayed price of drugs (43%), complicated drug choice (21%), and the perception that it was possible to handle more than one patient at a time when ePrescribing (13%). Moreover, 62% reported a lack of receipt from the pharmacy after successful transmission of an ePrescription. Although a majority (73%) of the physicians reported that they were always or often checking the ePrescription a last time before transmitting, 25% declared that they were seldom or never doing a last check. The respondents suggested a number of improvements, among others, to simplify the drug choice and the cancellation of ePrescriptions.</p> <p>Conclusion</p> <p>The Swedish physicians in the group studied were generally satisfied with their specific EHR-system and with ePrescribing as such. However, identified weaknesses warrant improvements of the EHR-systems as well as of their implementation in the individual health care organisation.</p

    Virus Capsid Dissolution Studied by Microsecond Molecular Dynamics Simulations

    Get PDF
    Dissolution of many plant viruses is thought to start with swelling of the capsid caused by calcium removal following infection, but no high-resolution structures of swollen capsids exist. Here we have used microsecond all-atom molecular simulations to describe the dynamics of the capsid of satellite tobacco necrosis virus with and without the 92 structural calcium ions. The capsid expanded 2.5% upon removal of the calcium, in good agreement with experimental estimates. The water permeability of the native capsid was similar to that of a phospholipid membrane, but the permeability increased 10-fold after removing the calcium, predominantly between the 2-fold and 3-fold related subunits. The two calcium binding sites close to the icosahedral 3-fold symmetry axis were pivotal in the expansion and capsid-opening process, while the binding site on the 5-fold axis changed little structurally. These findings suggest that the dissociation of the capsid is initiated at the 3-fold axis

    Mouse DRG Cell Line with Properties of Nociceptors

    Get PDF
    In vitro cell lines from DRG neurons aid drug discovery because they can be used for early stage, high-throughput screens for drugs targeting pain pathways, with minimal dependence on animals. We have established a conditionally immortal DRG cell line from the Immortomouse. Using immunocytochemistry, RT-PCR and calcium microfluorimetry, we demonstrate that the cell line MED17.11 expresses markers of cells committed to the sensory neuron lineage. Within a few hours under differentiating conditions, MED17.11 cells extend processes and following seven days of differentiation, express markers of more mature DRG neurons, such as NaV1.7 and Piezo2. However, at least at this time-point, the nociceptive marker NaV1.8 is not expressed, but the cells respond to compounds known to excite nociceptors, including the TRPV1 agonist capsaicin, the purinergic receptor agonist ATP and the voltage gated sodium channel agonist, veratridine. Robust calcium transients are observed in the presence of the inflammatory mediators bradykinin, histamine and norepinephrine. MED17.11 cells have the potential to replace or reduce the use of primary DRG culture in sensory, pain and developmental research by providing a simple model to study acute nociception, neurite outgrowth and the developmental specification of DRG neurons
    • …
    corecore