614 research outputs found

    The PANDA GEM-based TPC Prototype

    Full text link
    We report on the development of a GEM-based TPC prototype for the PANDA experiment. The design and requirements of this device will be illustrated, with particular emphasis on the properties of the recently tested GEM-detector, the characterization of the read-out electronics and the development of the tracking software that allows to evaluate the GEM-TPC data.Comment: submitted to NIMA 4 pages, 6 picture

    Predictors of personal polycyclic aromatic hydrocarbon exposures among pregnant minority women in New York City.

    Get PDF
    As part of a multiyear birth-cohort study examining the roles of pre- and postnatal environmental exposures on developmental deficits and asthma among children, we measured personal exposures to polycyclic aromatic hydrocarbons (PAHs) among 348 pregnant women in northern Manhattan and the South Bronx, New York. Nonsmoking African-American or Dominican women were identified and recruited into the study. During the third trimester of pregnancy, each subject wore a personal air monitor for 48 hr to determine exposure levels to nine PAH compounds. In this study, we examined levels of exposures to PAHs and tested for associations with potential predictor variables collected from questionnaires addressing socioeconomic factors and day-to-day activities during pregnancy as well as activities and environmental exposures during the 48-hr monitoring period. Reliable personal monitoring data for women who did not smoke during the monitoring period were available for 344 of 348 subjects. Mean PAH concentrations ranged from 0.06 ng/m3 for dibenz[a,h]anthracene to 4.1 ng/m3 for pyrene; mean benzo[a]pyrene concentration was 0.50 ng/m3. As found in previous studies, concentrations of most PAHs were higher in winter than in summer. Multiple linear regression analysis revealed associations between personal PAH exposures and several questionnaire variables, including time spent outdoors, residential heating, and indoor burning of incense. This is the largest study to date characterizing personal exposures to PAHs, a ubiquitous class of carcinogenic air contaminants in urban environments, and is unique in its focus on pregnant minority women

    Fast Photon Detection for Particle Identification with COMPASS RICH-1

    Get PDF
    Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several 10610^6 per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The new detection system consists of multi-anode photomultiplier tubes (MAPMT) and fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip. The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run. We present the photon detection design, constructive aspects and the first Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30 June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption of Fig.

    Fast photon detection for the COMPASS RICH detector

    Get PDF
    The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a wide momentum range. For the data taking in 2006, the COMPASS RICH has been upgraded in the central photon detection area (25% of the surface) with a new technology to detect Cherenkov photons at very high count rates of several 10^6 per second and channel and a new dead-time free read-out system, which allows trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of 576 visible and ultra-violet sensitive multi-anode photomultipliers with 16 channels each. The upgraded detector showed an excellent performance during the 2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06

    Reconstructing Gene Regulatory Networks That Control Hematopoietic Commitment.

    Get PDF
    Hematopoietic stem cells (HSCs) reside at the apex of the hematopoietic hierarchy, possessing the ability to self-renew and differentiate toward all mature blood lineages. Along with more specialized progenitor cells, HSCs have an essential role in maintaining a healthy blood system. Incorrect regulation of cell fate decisions in stem/progenitor cells can lead to an imbalance of mature blood cell populations-a situation seen in diseases such as leukemia. Transcription factors, acting as part of complex regulatory networks, are known to play an important role in regulating hematopoietic cell fate decisions. Yet, discovering the interactions present in these networks remains a big challenge. Here, we discuss a computational method that uses single-cell gene expression data to reconstruct Boolean gene regulatory network models and show how this technique can be applied to enhance our understanding of transcriptional regulation in hematopoiesis.Work in the author’s laboratory is supported by grants from the Wellcome, Bloodwise, Cancer Research UK, NIH-NIDDK and core support grants by the Wellcome to the Cambridge Institute for Medical Research and Wellcome & MRC Cambridge Stem Cell Institute. F.K.H. is a recipient of a Medical Research Council PhD Studentship

    The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Full text link
    A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor change

    Directed transport of CRP across in vitro models of the blood-saliva barrier strengthens the feasibility of salivary CRP as biomarker for neonatal sepsis

    Get PDF
    C-reactive protein (CRP) is a commonly used serum biomarker for detecting sepsis in neonates. After the onset of sepsis, serial measurements are necessary to monitor disease progression; therefore, a non-invasive detection method is beneficial for neonatal well-being. While some studies have shown a correlation between serum and salivary CRP levels in septic neonates, the causal link behind this correlation remains unclear. To investigate this relationship, CRP was examined in serum and saliva samples from 18 septic neonates and compared with saliva samples from 22 healthy neonates. While the measured blood and saliva concentrations of the septic neonates varied individually, a correlation of CRP levels between serum and saliva samples was observed over time. To clarify the presence of active transport of CRP across the blood–salivary barrier (BSB), transport studies were performed with CRP using in vitro models of oral mucosa and submandibular salivary gland epithelium. The results showed enhanced transport toward saliva in both models, supporting the clinical relevance for salivary CRP as a biomarker. Furthermore, CRP regulated the expression of the receptor for advanced glycation end products (RAGE) and the addition of soluble RAGE during the transport studies indicated a RAGE-dependent transport process for CRP from blood to saliva

    Public access defibrillation: Suppression of 16.7 Hz interference generated by the power supply of the railway systems

    Get PDF
    BACKGROUND: A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. METHODS: Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. RESULTS: The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. CONCLUSION: The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well
    • 

    corecore