542 research outputs found

    Gravastar energy conditions revisited

    Full text link
    We consider the gravastar model where the vacuum phase transition between the de Sitter interior and the Schwarzschild or Schwarzschild-de Sitter exterior geometries takes place at a single spherical delta-shell. We derive sharp analytic bounds on the surface compactness (2m/r) that follow from the requirement that the dominant energy condition (DEC) holds at the shell. In the case of Schwarzschild exterior, the highest surface compactness is achieved with the stiff shell in the limit of vanishing (dark) energy density in the interior. In the case of Schwarzschild-de Sitter exterior, in addition to the gravastar configurations with the shell under surface pressure, gravastar configurations with vanishing shell pressure (dust shells), as well as configurations with the shell under surface tension, are allowed by the DEC. Respective bounds on the surface compactness are derived for all cases. We also consider the speed of sound on the shell as derived from the requirement that the shell is stable against the radial perturbations. The causality requirement (sound speed not exceeding that of light) further restricts the space of allowed gravastar configurations.Comment: LaTeX/IOP-style, 16 pages, 2 figures, changes wrt v1: motivation for eq. (6) clarified, several referecnes added (to appear in Class. Quantum Grav.

    Biologically Inspired Monocular Vision Based Navigation and Mapping in GPS-Denied Environments

    Get PDF
    This paper presents an in-depth theoretical study of bio-vision inspired feature extraction and depth perception method integrated with vision-based simultaneous localization and mapping (SLAM). We incorporate the key functions of developed visual cortex in several advanced species, including humans, for depth perception and pattern recognition. Our navigation strategy assumes GPS-denied manmade environment consisting of orthogonal walls, corridors and doors. By exploiting the architectural features of the indoors, we introduce a method for gathering useful landmarks from a monocular camera for SLAM use, with absolute range information without using active ranging sensors. Experimental results show that the system is only limited by the capabilities of the camera and the availability of good corners. The proposed methods are experimentally validated by our self-contained MAV inside a conventional building

    The Schro¨\ddot{o}dinger-Poisson equations as the large-N limit of the Newtonian N-body system: applications to the large scale dark matter dynamics

    Get PDF
    In this paper it is argued how the dynamics of the classical Newtonian N-body system can be described in terms of the Schro¨\ddot{o}dinger-Poisson equations in the large NN limit. This result is based on the stochastic quantization introduced by Nelson, and on the Calogero conjecture. According to the Calogero conjecture, the emerging effective Planck constant is computed in terms of the parameters of the N-body system as M5/3G1/2(N/)1/6\hbar \sim M^{5/3} G^{1/2} (N/)^{1/6}, where is GG the gravitational constant, NN and MM are the number and the mass of the bodies, and is their average density. The relevance of this result in the context of large scale structure formation is discussed. In particular, this finding gives a further argument in support of the validity of the Schro¨\ddot{o}dinger method as numerical double of the N-body simulations of dark matter dynamics at large cosmological scales.Comment: Accepted for publication in the Euro. Phys. J.

    Long-lasting XUV activation of helium nanodroplets for avalanche ionization

    Full text link
    We study the dynamics of avalanche ionization of pure helium nanodroplets activated by a weak extreme-ultraviolet (XUV) pulse and driven by an intense near-infrared (NIR) pulse. In addition to a transient enhancement of ignition of a nanoplasma at short delay times 200\sim200~fs, long-term activation of the nanodroplets lasting up to a few nanoseconds is observed. Molecular dynamics simulations suggest that the short-term activation is caused by the injection of seed electrons into the droplets by XUV photoemission. Long-term activation appears due to electrons remaining loosely bound to photoions which form stable `snowball' structures in the droplets. Thus, we show that XUV irradiation can induce long-lasting changes of the strong-field optical properties of nanoparticles, potentially opening new routes to controlling avalanche-ionization phenomena in nanostructures and condensed-phase systems

    Exploring the genetics of irritable bowel syndrome: A GWA study in the general population and replication in multinational case-control cohorts

    Get PDF
    OBJECTIVE: IBS shows genetic predisposition, but adequately powered gene-hunting efforts have been scarce so far. We sought to identify true IBS genetic risk factors by means of genome-wide association (GWA) and independent replication studies. DESIGN: We conducted a GWA study (GWAS) of IBS in a general population sample of 11\u2005326 Swedish twins. IBS cases (N=534) and asymptomatic controls (N=4932) were identified based on questionnaire data. Suggestive association signals were followed-up in 3511 individuals from six case-control cohorts. We sought genotype-gene expression correlations through single nucleotide polymorphism (SNP)-expression quantitative trait loci interactions testing, and performed in silico prediction of gene function. We compared candidate gene expression by real-time qPCR in rectal mucosal biopsies of patients with IBS and controls. RESULTS: One locus at 7p22.1, which includes the genes KDELR2 (KDEL endoplasmic reticulum protein retention receptor 2) and GRID2IP (glutamate receptor, ionotropic, delta 2 (Grid2) interacting protein), showed consistent IBS risk effects in the index GWAS and all replication cohorts and reached p=9.31 710(-6) in a meta-analysis of all datasets. Several SNPs in this region are associated with cis effects on KDELR2 expression, and a trend for increased mucosal KDLER2 mRNA expression was observed in IBS cases compared with controls. CONCLUSIONS: Our results demonstrate that general population-based studies combined with analyses of patient cohorts provide good opportunities for gene discovery in IBS. The 7p22.1 and other risk signals detected in this study constitute a good starting platform for hypothesis testing in future functional investigations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions

    Glial and neuronal markers in cerebrospinal fluid in different types of multiple sclerosis

    Get PDF
    In the present study, CSF concentrations of NFL, t-tau, p-tau, GFAP, S-100B, YKL-40, MCP-1, α-sAPP, β-sAPP, and Aβ38, Aβ40, Aβ42 were measured in 324 MS patients to test whether a correlation among the biomarkers exists and whether the profile of CSF biomarkers varies among the different types of MS. The CSF concentrations of NFL were significantly higher in RRMS while CSF concentrations of GFAP were higher in PPMS. CSF concentrations of NFL correlated with YKL-40 in CIS patients while CSF concentrations of GFAP correlated with YKL-40 in RRMS patients

    Time-resolved XUV Opacity Measurements of Warm-Dense Aluminium

    Full text link
    The free-free opacity in plasmas is fundamental to our understanding of energy transport in stellar interiors and for inertial confinement fusion research. However, theoretical predictions in the challenging dense plasma regime are conflicting and there is a dearth of accurate experimental data to allow for direct model validation. Here we present time-resolved transmission measurements in solid-density Al heated by an XUV free-electron laser. We use a novel functional optimization approach to extract the temperature-dependent absorption coefficient directly from an oversampled pool of single-shot measurements, and find a pronounced enhancement of the opacity as the plasma is heated to temperatures of order the Fermi energy. Plasma heating and opacity-enhancement is observed on ultrafast time scales, within the duration of the femtosecond XUV pulse. We attribute further rises in the opacity on ps timescales to melt and the formation of warm-dense matter

    Adult Consequences of Late Adolescent Alcohol Consumption: A Systematic Review of Cohort Studies

    Get PDF
    In a systematic review of cohort studies of adolescent drinking and later outcomes, Jim McCambridge and colleagues show that although studies suggest links to worse adult physical and mental health and social consequences, existing evidence is of poor quality

    The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve

    Get PDF
    Background: 112 patients who received small and medium sized St.Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. Material and methods: 46 woman and 66 men, aged 61.8 +/- 9.7 (18-75) years, were operated on for aortic regurgitation (17), stenosis (65), or mixed dysfunction (30). Valve sizes were 19 mm (6), 21 mm (33), 23 mm (41), 25 mm (30). Two patients receiving size 27 valves were excluded from the hemodynamic evaluation. Pledgets were used in 100 patients, everted mattress in 66 and simple interrupted sutures in 21. Valve orientation varied and was dependent on the surgeons' choice. 34 patients (30.4%) underwent concomitant coronary artery surgery. Results: There were two early deaths (1.8%) and three late deaths, one because of pancreatic cancer. Late events during follow-up were: non structural dysfunction (1), bleeding (2), thromboembolism (2). At one year follow up 93% of the patients were in NYHA classes 1-2 versus 47.8% preoperatively. Dobutamine stress echocardiography (DSE) was performed in a total of 66 and maximal peak stress was reached in 61 patients. During DSE testing, the following statistically significant changes took place: Heart rate increased by 73.0%, cardiac output by 85.5%, left ventriclular ejection fraction by 19.6%, and maximal mean prosthetic transvalvular gradient by 133.8%, whereas the effective orifice area index did not change. Left ventricular mass fell during one year from 215 +/- 63 to 197 +/- 62 g (p < 0.05). Conclusion: The Dobutamine test induces a substantial stress, well suitable for echocardiographic assessment of prosthesis valve function and can be performed in the majority of the patients. The changes in pressure gradients add to the hemodynamic characteristics of the various valve sizes. In our patients the St. Jude Regent valve performed satisfactory at rest and under pharmacological stress situation
    corecore