3,433 research outputs found

    Quantification of Degradation of Chlorinated Hydrocarbons in Saturated Low Permeability Sediments Using Compound-Specific Isotope Analysis

    Get PDF
    This field and modeling study aims to reveal if degradation of chlorinated hydrocarbons in low permeability sediments can be quantified using compound-specific isotope analysis (CSIA). For that purpose, the well-characterized Borden research site was selected, where an aquifer−aquitard system was artificially contaminated by a three component chlorinated solvent mixture (tetrachloroethene (PCE) 45 vol %, trichloroethene (TCE) 45 vol %, and chloroform (TCM) 10 vol %). Nearly 15 years after the contaminant release, several high-resolution concentration and CSIA profiles were determined for the chlorinated hydrocarbons that had diffused into the clayey aquitard. The CSIA profiles showed large shifts of carbon isotope ratios with depth (up to 24‰) suggesting that degradation occurs in the aquitard despite the small pore sizes. Simulated scenarios without or with uniform degradation failed to reproduce the isotope data, while a scenario with decreasing degradation with depth fit the data well. This suggests that nutrients had diffused into the aquitard favoring stronger degradation close to the aquifer−aquitard interface than with increasing depth. Moreover, the different simulation scenarios showed that CSIA profiles are more sensitive to different degradation conditions compared to concentration profiles highlighting the power of CSIA to constrain degradation activities in aquitards

    Increase of the mean inner Coulomb potential in Au clusters induced by surface tension and its implication for electron scattering

    Full text link
    Electron holography in a transmission electron microscope was applied to measure the phase shift induced by Au clusters as a function of the cluster size. Large phase shifts Df observed for small Au clusters cannot be described by the well-known equation Df=C_E V_0 t (C_E: interaction constant, V_0: mean inner Coulomb potential (MIP) of bulk gold, t: cluster thickness). The rapid increase of the Au MIP with decreasing cluster size derived from Df, can be explained by the compressive strain of surface atoms in the cluster

    Effects of EDTA-Induced Hypocalcaemia and Stress on Plasma TNF-α, IL-1-ra, G-CSF, GM-CSF and S-100 in Dairy Cows

    Get PDF
    The pathophysiology of postparturient paresis is still not completely understood. Knowledge recently acquired in immunology, endocrinology and cell physiology has still to be integrated in order to elucidate the aetiopathogenesis of the disease. For that purpose, the effect of the EDTA infusion model on the plasma concentrations of selected cytokines and growth factors, and of a calcium binding protein was examined in dairy cows. Six 6- to 11-year-old Brown Swiss cows in mid lactation were infused with a 5% solution of Na2EDTA in one jugular vein over a period of 5 h. Blood samples were collected from the contralateral side daily two days before, and then hourly for five hours during the infusion, hourly for five hours after the end of the infusion, and once daily for 10 days thereafter. The plasma concentrations of cortisol, tumour necrosis factor-α, interleukin-1 receptor antagonist, granulocyte colony-stimulating factor, granulocyte and macrophage colony-stimulating factor, and the calcium binding protein S-100 were determined. Before the EDTA infusion, during the infusion and for two days thereafter, the mean plasma concentrations of cortisol were significantly higher than those from days 4 to 10 after the infusion. The plasma concentrations of tumour necrosis factor-α and interleukin-1 receptor antagonist followed a similar profile. At the end of EDTA infusion, low concentrations of granulocyte colony-stimulating factor were detected in one cow only. On days 3 and 4, the mean plasma concentrations of granulocyte colony-stimulating factor were significantly higher than the pre-infusion values, but this was followed by a significant decrease on post-infusion day 5. From day 4 to 7, the plasma concentrations of S-100 were significantly lower than the pre-infusion values. The importance of these findings in the pathophysiology of postparturient paresis remains to be establishe

    Design and construction of an optical test bed for LISA imaging systems and tilt-to-length coupling

    Get PDF
    The laser interferometer space antenna (LISA) is a future space-based interferometric gravitational-wave detector consisting of three spacecraft in a triangular configuration. The interferometric measurements of path length changes between satellites will be performed on optical benches in the satellites. Angular misalignments of the interfering beams couple into the length measurement and represent a significant noise source. Imaging systems will be used to reduce this tilt-to-length coupling. We designed and constructed an optical test bed to experimentally investigate tilt-to-length coupling. It consists of two separate structures, a minimal optical bench and a telescope simulator. The minimal optical bench comprises the science interferometer where the local laser is interfered with light from a remote spacecraft. In our experiment, a simulated version of this received beam is generated on the telescope simulator. The telescope simulator provides a tilting beam, a reference interferometer and an additional static beam as a phase reference. The tilting beam can either be a flat-top beam or a Gaussian beam. We avoid tilt-to-length coupling in the reference interferometer by using a small photo diode placed at an image of the beam rotation point. We show that the test bed is operational with an initial measurement of tilt-to-length coupling without imaging systems. Furthermore, we show the design of two different imaging systems whose performance will be investigated in future experiments

    Smooth stable and unstable manifolds for stochastic partial differential equations

    Full text link
    Invariant manifolds are fundamental tools for describing and understanding nonlinear dynamics. In this paper, we present a theory of stable and unstable manifolds for infinite dimensional random dynamical systems generated by a class of stochastic partial differential equations. We first show the existence of Lipschitz continuous stable and unstable manifolds by the Lyapunov-Perron's method. Then, we prove the smoothness of these invariant manifolds

    The novel mTOR inhibitor RAD001 (Everolimus) induces antiproliferative effects in human pancreatic neuroendocrine tumor cells

    Get PDF
    Background/Aim: Tumors exhibiting constitutively activated PI(3) K/Akt/mTOR signaling are hypersensitive to mTOR inhibitors such as RAD001 (everolimus) which is presently being investigated in clinical phase II trials in various tumor entities, including neuroendocrine tumors (NETs). However, no preclinical data about the effects of RAD001 on NET cells have been published. In this study, we aimed to evaluate the effects of RAD001 on BON cells, a human pancreatic NET cell line that exhibits constitutively activated PI(3) K/Akt/mTOR signaling. Methods: BON cells were treated with different concentrations of RAD001 to analyze its effect on cell growth using proliferation assays. Apoptosis was examined by Western blot analysis of caspase-3/PARP cleavage and by FACS analysis of DNA fragmentation. Results: RAD001 potently inhibited BON cell growth in a dose-dependent manner which was dependent on the serum concentration in the medium. RAD001-induced growth inhibition involved G0/G1-phase arrest as well as induction of apoptosis. Conclusion: In summary, our data demonstrate antiproliferative and apoptotic effects of RAD001 in NET cells in vitro supporting its clinical use in current phase II trials in NET patients. Copyright (c) 2007 S. Karger AG, Basel

    Beyond the required LISA free-fall performance: new LISA pathfinder results down to 20  μHz

    Get PDF
    In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20  μHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.05)  fm s^{-2}/sqrt[Hz] above 2 mHz and (6±1)×10  fm s^{-2}/sqrt[Hz] at 20  μHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency

    Equilibrium Constants of Various Polyol-borate Systems

    Get PDF
    This 26 page thesis examines the polyol-borate system

    Sub-femto-g free fall for space-based gravitational wave observatories: LISA pathfinder results

    Get PDF
    We report the first results of the LISA Pathfinder in-flight experiment. The results demonstrate that two free-falling reference test masses, such as those needed for a space-based gravitational wave observatory like LISA, can be put in free fall with a relative acceleration noise with a square root of the power spectral density of 5.2 ± 0.1 fm s−2/√Hz or (0.54 ± 0.01) × 10−15 g/√Hz, with g the standard gravity, for frequencies between 0.7 and 20 mHz. This value is lower than the LISA Pathfinder requirement by more than a factor 5 and within a factor 1.25 of the requirement for the LISA mission, and is compatible with Brownian noise from viscous damping due to the residual gas surrounding the test masses. Above 60 mHz the acceleration noise is dominated by interferometer displacement readout noise at a level of (34.8 ± 0.3) fm/√Hz, about 2 orders of magnitude better than requirements. At f ≤ 0.5 mHz we observe a low-frequency tail that stays below 12 fm s−2/√Hz down to 0.1 mHz. This performance would allow for a space-based gravitational wave observatory with a sensitivity close to what was originally foreseen for LISA
    corecore