3,057 research outputs found

    The influence of the aortic valve angle on the hemodynamic features of the thoracic aorta

    Get PDF
    Since the first observation of a helical flow pattern in aortic blood flow, the existence of helical blood flow has been found to be associated with various pathological conditions such as bicuspid aortic valve, aortic stenosis, and aortic dilatation. However, an understanding of the development of helical blood flow and its clinical implications are still lacking. In our present study, we hypothesized that the direction and angle of aortic inflow can influence helical flow patterns and related hemodynamic features in the thoracic aorta. Therefore, we investigated the hemodynamic features in the thoracic aorta and various aortic inflow angles using patient-specific vascular phantoms that were generated using a 3D printer and time-resolved, 3D, phase-contrast magnetic resonance imaging (PC-MRI). The results show that the rotational direction and strength of helical blood flow in the thoracic aorta largely vary according to the inflow direction of the aorta, and a higher helical velocity results in higher wall shear stress distributions. In addition, right-handed rotational flow conditions with higher rotational velocities imply a larger total kinetic energy than left-handed rotational flow conditions with lower rotational velocities.115Ysciescopu

    Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications

    Get PDF
    Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Various fluid dynamic biomarkers for possible clinical usage are also described, including wall shear stress, turbulent kinetic energy, and relative pressure. Lastly, this article provides an overview of the clinical applications of 4D PC-MRI in various cardiovascular regions.113Ysciescopuskc

    The Role of Repeated Exposure to Multimodal Input in Incidental Acquisition of Foreign Language Vocabulary

    Get PDF
    Prior research has reported incidental vocabulary acquisition with complete beginners in a foreign language (FL), within 8 exposures to auditory and written FL word forms presented with a picture depicting their meaning. However, important questions remain about whether acquisition occurs with fewer exposures to FL words in a multimodal situation and whether there is a repeated exposure effect. Here we report a study where the number of exposures to FL words in an incidental learning phase varied between 2, 4, 6, and 8 exposures. Following the incidental learning phase, participants completed an explicit learning task where they learned to recognize written translation equivalents of auditory FL word forms, half of which had occurred in the incidental learning phase. The results showed that participants performed better on the words they had previously been exposed to, and that this incidental learning effect occurred from as little as 2 exposures to the multimodal stimuli. In addition, repeated exposure to the stimuli was found to have a larger impact on learning during the first few exposures and decrease thereafter, suggesting that the effects of repeated exposure on vocabulary acquisition are not necessarily constant

    Application of Ozone-Assisted Membrane Cleaning for Natural Organic Matter Fouled Membranes

    Get PDF
    The popularity of membrane technology in water treatment has been rising for over last 50 years due to wide range of filtration processes and applications, cost effective production and installation as well as safe and efficient water production. However, the development and improvement of membranes is ongoing due to number of weaknesses. Membrane fouling is a major drawback of membrane application in water and waste water treatment. Mostly caused by natural organic matter (NOM), fouling forms a layer on top of the membrane and blocks pores reducing the water permeation and can be potentially destructive to the membrane structure. The issue of membrane fouling can be addressed during membrane manufacturing, maintenance and operation. In the current study, the graphene-based nanomaterials (GBN) were incorporated in polyvinylidene fluoride (PVDF) to manufacture membranes via the phase-inversion technique. The resulting membranes show significant improvement to the properties of the pure PVDF membranes and their antifouling ability. The addition of GBN enhanced the water permeation by over 79% as a result of increased membrane hydrophilicity. Although this enhancement is beneficial, membrane fouling remained an issue despite the observed improvement. In this study, ozone, which is an effective oxidant, was evaluated as a novel technique for the cleaning of humic acid-fouled membranes. When ozone cleaning was applied to the humic acid-fouled membranes, reestablishment of close to original flux values was observed after just 30 min of cleaning. This statement is supported by SEM images that give an insight into the fouling of the membrane surface after the application of the cleaning methods. The data indicate that ozone is an effective technique for membrane cleaning against NOM-induced fouling

    Centrality dependence of charged hadron production in deuteron+gold and nucleon+gold collisions at sqrt(s_NN)=200 GeV

    Full text link
    We present transverse momentum (p_T) spectra of charged hadrons measured in deuteron-gold and nucleon-gold collisions at \sqrts = 200 GeV for four centrality classes. Nucleon-gold collisions were selected by tagging events in which a spectator nucleon was observed in one of two forward rapidity detectors. The spectra and yields were investigated as a function of the number of binary nucleon-nucleon collisions, \nu, suffered by deuteron nucleons. A comparison of charged particle yields to those in p+p collisions show that the yield per nucleon-nucleon collision saturates with \nu for high momentum particles. We also present the charged hadron to neutral pion ratios as a function of p_T.Comment: 330 authors, 15 pages text, 16 figures, 3 tables. Submitted to Phys. Rev. Lett. v2 has minor changes to reflect revisions during review process. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are (or will be) publicly available at http://www.phenix.bnl.gov/papers.htm

    Azimuthal Angle Correlations for Rapidity Separated Hadron Pairs in d+Au Collisions at sqrt(s_NN) = 200 GeV

    Get PDF
    We report on two-particle azimuthal angle correlations between charged hadrons at forward/backward (deuteron/gold going direction) rapidity and charged hadrons at mid-rapidity in deuteron-gold (d+Au) and proton-proton (p+p) collisions at sqrt(s_NN) = 200 GeV. Jet structures are observed in the correlations which we quantify in terms of the conditional yield and angular width of away side partners. The kinematic region studied here samples partons in the gold nucleus carrying nucleon momentum fraction x~0.1 to x~0.01. Within this range, we find no x dependence of the jet structure in d+Au collisions.Comment: 330 authors, 6 pages text, 4 figures, no tables. Submitted to Phys. Rev. Lett. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are (or will be) publicly available at http://www.phenix.bnl.gov/papers.htm

    Deuteron and antideuteron production in Au+Au collisions at sqrt(s_NN)=200 GeV

    Get PDF
    The production of deuterons and antideuterons in the transverse momentum range 1.1 < p_T < 4.3 GeV/c at mid-rapidity in Au + Au collisions at sqrt(s_NN)=200 GeV has been studied by the PHENIX experiment at RHIC. A coalescence analysis comparing the deuteron and antideuteron spectra with those of protons and antiprotons, has been performed. The coalescence probability is equal for both deuterons and antideuterons and increases as a function of p_T, which is consistent with an expanding collision zone. Comparing (anti)proton yields p_bar/p = 0.73 +/- 0.01, with (anti)deuteron yields: d_bar/d = 0.47 +/- 0.03, we estimate that n_bar/n = 0.64 +/- 0.04.Comment: 326 authors, 6 pages text, 5 figures, 1 Table. Submitted to PRL. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are (or will be) publicly available at http://www.phenix.bnl.gov/papers.htm
    corecore