348 research outputs found

    Quantum Monte Carlo Study of High Pressure Solid Molecular Hydrogen

    Full text link
    We use the diffusion quantum Monte Carlo (DMC) method to calculate the ground state phase diagram of solid molecular hydrogen and examine the stability of the most important insulating phases relative to metallic crystalline molecular hydrogen. We develop a new method to account for finite-size errors by combining the use of twist-averaged boundary conditions with corrections obtained using the Kwee-Zhang-Krakauer (KZK) functional in density functional theory. To study band-gap closure and find the metallization pressure, we perform accurate quasi-particle many-body calculations using the GWGW method. In the static approximation, our DMC simulations indicate a transition from the insulating Cmca-12 structure to the metallic Cmca structure at around 375 GPa. The GWGW band gap of Cmca-12 closes at roughly the same pressure. In the dynamic DMC phase diagram, which includes the effects of zero-point energy, the Cmca-12 structure remains stable up to 430 GPa, well above the pressure at which the GWGW band gap closes. Our results predict that the semimetallic state observed experimentally at around 360 GPa [Phys. Rev. Lett. {\bf 108}, 146402 (2012)] may correspond to the Cmca-12 structure near the pressure at which the band gap closes. The dynamic DMC phase diagram indicates that the hexagonal close packed P63/mP6_3/m structure, which has the largest band gap of the insulating structures considered, is stable up to 220 GPa. This is consistent with recent X-ray data taken at pressures up to 183 GPa [Phys. Rev. B {\bf 82}, 060101(R) (2010)], which also reported a hexagonal close packed arrangement of hydrogen molecules

    Unconventional phase III of high-pressure solid hydrogen

    Get PDF
    We reassess the phase diagram of high-pressure solid hydrogen using mean-field and many-body wave function based approaches to determine the nature of phase III of solid hydrogen. To discover the best candidates for phase III, density functional theory calculations within the meta-generalized gradient approximation by means of the strongly constrained and appropriately normed (SCAN) semilocal density functional are employed. We study eleven molecular structures with different symmetries, which are the most competitive phases, within the pressure range of 100 to 500~GPa. The SCAN phase diagram predicts that the C2/c24C2/c-24 and P612236P6_122-36 structures are the best candidates for phase III with an energy difference of less than 1~meV/atom. To verify the stability of the competitive insulator structures of C2/c24C2/c-24 and P612236P6_122-36, we apply the diffusion Monte Carlo (DMC) method to optimise the percentage α\alpha of exact-exchange in the trial many-body wave function. We found that the optimised α\alpha equals to 40%40 \%, and denote the corresponding exchange and correlation functional as PBE1. The energy gain with respect to the well-known hybrid functional PBE0, where α=25%\alpha = 25\%, varies with density and structure. The PBE1-DMC enthalpy-pressure phase diagram predicts that the P612236P6_122-36 structure is stable up to 210~GPa, where it transforms to the C2/c24C2/c-24. Hence, we predict that the phase III of high-pressure solid hydrogen is polymorphic.Comment: Accepted for publication in Phys. Rev.

    In vivo potassium MRI of the human heart

    Get PDF
    PURPOSE: Potassium ions (K(+)) play a critical role in cardiac electrophysiology, and changes in their concentration reflect pathophysiological processes related to cardiovascular diseases. Here, we investigated the feasibility of in vivo (39)K MRI of the human heart. To achieve this, we developed, evaluated, and applied a (39)K/(1)H RF coil, which is tailored for (39)K MRI of human heart at 7.0T. METHODS: The performance of the (39)K/(1)H RF coil was evaluated by electromagnetic field and specific absorption ratio simulations using 2 (male/female) human voxel models. The RF coil was evaluated at the bench and applied in an in vivo proof-of-principle study involving 7 healthy volunteers. The experiments were performed using a 7.0T whole-body MR system in conjunction with a 3D density-adapted projection reconstruction imaging technique. RESULTS: For in vivo (39)K MRI of the human heart, a nominal spatial resolution of 14.5 × 14.5 × 14.5 mm(3) within a total scan time of 30 min was achieved. The average SNR within the heart was 9.6 ± 2.4. CONCLUSION: This work validates the design of a (39)K/(1)H RF coil for cardiac MR at 7.0T and demonstrates for the first time in vivo the feasibility of (39)K MRI of the human heart

    Multiband diffusion-weighted MRI of the eye and orbit free of geometric distortions using a RARE-EPI hybrid

    Get PDF
    Diffusion-weighted imaging (DWI) provides information on tissue microstructure. Single-shot echo planar imaging (EPI) is the most common technique for DWI applications in the brain, but is prone to geometric distortions and signal voids. Rapid acquisition with relaxation enhancement [RARE, also known as fast spin echo (FSE)] imaging presents a valuable alternative to DWI with high anatomical accuracy. This work proposes a multi-shot diffusion-weighted RARE-EPI hybrid pulse sequence, combining the anatomical integrity of RARE with the imaging speed and radiofrequency (RF) power deposition advantage of EPI. The anatomical integrity of RARE-EPI was demonstrated and quantified by center of gravity analysis for both morphological images and diffusion-weighted acquisitions in phantom and in vivo experiments at 3.0 T and 7.0 T. The results indicate that half of the RARE echoes in the echo train can be replaced by EPI echoes whilst maintaining anatomical accuracy. The reduced RF power deposition of RARE-EPI enabled multiband RF pulses facilitating simultaneous multi-slice imaging. This study shows that diffusion-weighted RARE-EPI has the capability to acquire high fidelity, distortion-free images of the eye and the orbit. It is shown that RARE-EPI maintains the immunity to B0 inhomogeneities reported for RARE imaging. This benefit can be exploited for the assessment of ocular masses and pathological changes of the eye and the orbit

    Measuring The Evolutionary Rate Of Cooling Of ZZ Ceti

    Get PDF
    We have finally measured the evolutionary rate of cooling of the pulsating hydrogen atmosphere (DA) white dwarf ZZ Ceti (Ross 548), as reflected by the drift rate of the 213.13260694 s period. Using 41 yr of time-series photometry from 1970 November to 2012 January, we determine the rate of change of this period with time to be dP/dt = (5.2 +/- 1.4) x 10(-15) s s(-1) employing the O - C method and (5.45 +/- 0.79) x 10(-15) s s(-1) using a direct nonlinear least squares fit to the entire lightcurve. We adopt the dP/dt obtained from the nonlinear least squares program as our final determination, but augment the corresponding uncertainty to a more realistic value, ultimately arriving at the measurement of dP/dt = (5.5 +/- 1.0) x 10(-15) s s(-1). After correcting for proper motion, the evolutionary rate of cooling of ZZ Ceti is computed to be (3.3 +/- 1.1) x 10(-15) s s(-1). This value is consistent within uncertainties with the measurement of (4.19 +/- 0.73) x 10(-15) s s(-1) for another similar pulsating DA white dwarf, G 117-B15A. Measuring the cooling rate of ZZ Ceti helps us refine our stellar structure and evolutionary models, as cooling depends mainly on the core composition and stellar mass. Calibrating white dwarf cooling curves with this measurement will reduce the theoretical uncertainties involved in white dwarf cosmochronometry. Should the 213.13 s period be trapped in the hydrogen envelope, then our determination of its drift rate compared to the expected evolutionary rate suggests an additional source of stellar cooling. Attributing the excess cooling to the emission of axions imposes a constraint on the mass of the hypothetical axion particle.NSF AST-1008734, AST-0909107Norman Hackerman Advanced Research Program 003658-0252-2009Astronom

    Measuring The Evolutionary Rate Of Cooling Of ZZ Ceti

    Get PDF
    We have finally measured the evolutionary rate of cooling of the pulsating hydrogen atmosphere (DA) white dwarf ZZ Ceti (Ross 548), as reflected by the drift rate of the 213.13260694 s period. Using 41 yr of time-series photometry from 1970 November to 2012 January, we determine the rate of change of this period with time to be dP/dt = (5.2 +/- 1.4) x 10(-15) s s(-1) employing the O - C method and (5.45 +/- 0.79) x 10(-15) s s(-1) using a direct nonlinear least squares fit to the entire lightcurve. We adopt the dP/dt obtained from the nonlinear least squares program as our final determination, but augment the corresponding uncertainty to a more realistic value, ultimately arriving at the measurement of dP/dt = (5.5 +/- 1.0) x 10(-15) s s(-1). After correcting for proper motion, the evolutionary rate of cooling of ZZ Ceti is computed to be (3.3 +/- 1.1) x 10(-15) s s(-1). This value is consistent within uncertainties with the measurement of (4.19 +/- 0.73) x 10(-15) s s(-1) for another similar pulsating DA white dwarf, G 117-B15A. Measuring the cooling rate of ZZ Ceti helps us refine our stellar structure and evolutionary models, as cooling depends mainly on the core composition and stellar mass. Calibrating white dwarf cooling curves with this measurement will reduce the theoretical uncertainties involved in white dwarf cosmochronometry. Should the 213.13 s period be trapped in the hydrogen envelope, then our determination of its drift rate compared to the expected evolutionary rate suggests an additional source of stellar cooling. Attributing the excess cooling to the emission of axions imposes a constraint on the mass of the hypothetical axion particle.NSF AST-1008734, AST-0909107Norman Hackerman Advanced Research Program 003658-0252-2009Astronom

    Development of clinical simultaneous SPECT/MRI

    Get PDF
    There is increasing clinical use of combined positron emission tomography (PET) and magnetic resonance imaging (MRI) but to date there has been no clinical system developed capable of simultaneous single photon emission computed tomography (SPECT) and MRI. There has been development of preclinical systems, but there are several challenges faced by researchers who are developing a clinical prototype including the need for the system to be compact and stationary with MRI-compatible components. The limited work in this area is described with specific reference to the Integrated SPECT/MRI for Enhanced stratification in Radio-chemo Therapy (INSERT) project, which is at an advanced stage of developing a clinical prototype. Issues of SPECT/MRI compatibility are outlined and the clinical appeal of such a system is discussed, especially in the management of brain tumour treatment

    臨床応用の可能なマウス型モノクローナル抗体の作製 - 早期癌診断へのモノクローナル抗体2H6の応用 -

    Get PDF
    Here we present a facile synthetic method yielding a linear form of polydopamine via Kumada-coupling, which can be converted into water-soluble melanin, generating high contrast in photoacoustic imaging
    corecore