25 research outputs found

    Safety of in-hospital insertable cardiac monitor procedures performed outside the traditional settings: results from the Reveal LINQ in-office 2 international study

    Get PDF
    Duration; Holding area; Insertable cardiac monitorDuració; Sala d'espera; Monitor cardíac inseribleDuración; Sala de espera; Monitor cardíaco insertableBACKGROUND: Historically, the majority of insertable cardiac monitor (ICM) procedures were performed in the cardiac catheterization (cath) lab, electrophysiology (EP) lab, or operating room (OR). The miniaturization of ICMs allows the procedure to be relocated within the hospital without compromising patient safety. We sought to estimate the rate of untoward events associated with procedures performed within the hospital but outside the traditional settings and to characterize resource utilization, procedure time intervals, and physician experience. METHODS: The Reveal LINQ in-Office 2 (RIO 2) International study was a single arm, multicenter, prospective study. Patients indicated for an ICM and willing to undergo device insertion outside the cath/EP lab or OR were eligible and followed for 90 days after insertion. RESULTS: A total of 191 patients (45.5% female aged 63.8 ± 26.9 years) underwent successful Reveal LINQ ICM insertion at 17 centers in Europe, Canada and Australia. The median total visit duration was 106 min (interquartile range [IQR]: 55-61). Patient preparation and patient education accounted for 10 min (IQR: 5-20) and 10 min (IQR: 8-15) of total visit duration, respectively. Preparation and education occurred in the procedure room for 90.6 and 60.2% of patients, respectively. There were no untoward events (0.0, 95% CI: 0.0-2.1%) though four patients presented with procedure-related adverse events that did not require invasive intervention. Physicians rated procedure location as convenient or very convenient. CONCLUSIONS: The Reveal LINQ™ ICM insertion can be safely and efficiently performed in the hospital outside the cath/EP lab or OR. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT02412488 ; registered on April 9, 2015.This study was sponsored by Medtronic, Inc

    Albiglutide and cardiovascular outcomes in patients with type 2 diabetes and cardiovascular disease (Harmony Outcomes): a double-blind, randomised placebo-controlled trial

    Get PDF
    Background: Glucagon-like peptide 1 receptor agonists differ in chemical structure, duration of action, and in their effects on clinical outcomes. The cardiovascular effects of once-weekly albiglutide in type 2 diabetes are unknown. We aimed to determine the safety and efficacy of albiglutide in preventing cardiovascular death, myocardial infarction, or stroke. Methods: We did a double-blind, randomised, placebo-controlled trial in 610 sites across 28 countries. We randomly assigned patients aged 40 years and older with type 2 diabetes and cardiovascular disease (at a 1:1 ratio) to groups that either received a subcutaneous injection of albiglutide (30–50 mg, based on glycaemic response and tolerability) or of a matched volume of placebo once a week, in addition to their standard care. Investigators used an interactive voice or web response system to obtain treatment assignment, and patients and all study investigators were masked to their treatment allocation. We hypothesised that albiglutide would be non-inferior to placebo for the primary outcome of the first occurrence of cardiovascular death, myocardial infarction, or stroke, which was assessed in the intention-to-treat population. If non-inferiority was confirmed by an upper limit of the 95% CI for a hazard ratio of less than 1·30, closed testing for superiority was prespecified. This study is registered with ClinicalTrials.gov, number NCT02465515. Findings: Patients were screened between July 1, 2015, and Nov 24, 2016. 10 793 patients were screened and 9463 participants were enrolled and randomly assigned to groups: 4731 patients were assigned to receive albiglutide and 4732 patients to receive placebo. On Nov 8, 2017, it was determined that 611 primary endpoints and a median follow-up of at least 1·5 years had accrued, and participants returned for a final visit and discontinuation from study treatment; the last patient visit was on March 12, 2018. These 9463 patients, the intention-to-treat population, were evaluated for a median duration of 1·6 years and were assessed for the primary outcome. The primary composite outcome occurred in 338 (7%) of 4731 patients at an incidence rate of 4·6 events per 100 person-years in the albiglutide group and in 428 (9%) of 4732 patients at an incidence rate of 5·9 events per 100 person-years in the placebo group (hazard ratio 0·78, 95% CI 0·68–0·90), which indicated that albiglutide was superior to placebo (p<0·0001 for non-inferiority; p=0·0006 for superiority). The incidence of acute pancreatitis (ten patients in the albiglutide group and seven patients in the placebo group), pancreatic cancer (six patients in the albiglutide group and five patients in the placebo group), medullary thyroid carcinoma (zero patients in both groups), and other serious adverse events did not differ between the two groups. There were three (<1%) deaths in the placebo group that were assessed by investigators, who were masked to study drug assignment, to be treatment-related and two (<1%) deaths in the albiglutide group. Interpretation: In patients with type 2 diabetes and cardiovascular disease, albiglutide was superior to placebo with respect to major adverse cardiovascular events. Evidence-based glucagon-like peptide 1 receptor agonists should therefore be considered as part of a comprehensive strategy to reduce the risk of cardiovascular events in patients with type 2 diabetes. Funding: GlaxoSmithKline

    Anaemia and renal dysfunction are independently associated with BNP and NT-proBNP levels in patients with heart failure

    No full text
    Background: Anaemia may affect 13-type natriuretic peptide (BNP) and N-terminal proBNP (NT-proBNP) levels, but this has not been well described in heart failure (1417) patients without the exclusion of patients with renal dysfunction. Aims: To study the influence of both anaemia and renal function on BNP and NT-proBNP levels in a large group of hospitalised HF patients. Methods and results: We studied 541 patients hospitalised for HF (mean age 71 +/- 11 years, 62% male, and left ventricular ejection fraction 0.33 +/- 0.14). Of these patients, 30% (n= 159) were anaemic (women: Hb <7.5 mmol/l, men: Hb <8.1 mmol/1). Of the 159 anaemic patients, 73% had renal dysfunction (eGFR <60 ml/min/1.73 m(2)) and of the non-anaemic patients, 57% had renal dysfunction. BNP and NT-proBNP levels were measured in all patients before discharge. In multivariable analyses both plasma haemoglobin and eGFR were independently related to the levels of BNP and NT-proBNP (standardised beta's of -0.16, -0.14 [BNP] and -0.19, -0.26 [NT-proBNP] respectively, P-values <0.01). Conclusion: Anaemia and renal dysfunction are related to increased BNP and NT-proBNP levels, independent of the severity of HE These results indicate that both anaemia and renal dysfunction should be taken into consideration during the interpretation of BNP and NT-proBNP levels in HF patients. (c) 2007 European Society of Cardiology. Published by Elsevier B.V. All rights reserved

    Reschedule break for Chinese New Year

    No full text
    This study was performed to gain further insight in the heterogeneity of monocytes in the different categories of acute coronary syndrome (ACS), especially between patients with unstable angina pectoris, ST-elevation myocardial infarction (STEMI), and non-ST-elevation myocardial infarction (NSTEMI). For this purpose, blood samples were collected in the acute phase from patients presenting with an ACS. These samples were examined with multiparameter flow cytometry to identify the different monocyte subsets and to analyze the expression of monocyte-associated molecules. Leukocytes, as well as an absolute number of monocytes, showed a clear and significant increase in patients with STEMI. This increase was seen in all subtypes of monocytes. The classical monocytes (CD14++CD16-) of patients with an NSTEMI had a significantly increased CD11b expression when compared to the control group, while these cells showed a decreased expression pattern in STEMI patients. This increased CD11b-expression was also seen in the intermediate monocytes of NSTEMI, while it was almost completely downregulated on the intermediate monocytes of STEMI. Finally, CX3CR1, which is almost exclusively expressed on intermediate and nonclassical monocytes, showed a significant decrease in expression in patients with STEMI. In conclusion, intermediate and nonclassical monocytes have a different immunophenotypic pattern in patients with STEMI versus NSTEMI. These differences reflect the pro-inflammatory state of the monocytes in NSTEMI and can be used as target molecules for novel therapeutic strategies to diminish the migration of proinflammatory monocytes into the myocardial tissue. (c) 2017 International Society for Advancement of Cytometry</p

    Factor XIa and Thrombin Generation Are Elevated in Patients with Acute Coronary Syndrome and Predict Recurrent Cardiovascular Events

    No full text
    In acute coronary syndrome (ACS) cardiac cell damage is preceded by thrombosis. Therefore, plasma coagulation markers may have additional diagnostic relevance in ACS. By using novel coagulation assays this study aims to gain more insight into the relationship between the coagulation system and ACS.We measured plasma thrombin generation, factor XIa and D-dimer levels in plasma from ACS (n = 104) and non-ACS patients (n = 42). Follow-up measurements (n = 73) were performed at 1 and 6 months. Associations between coagulation markers and recurrent cardiovascular events were calculated by logistic regression analysis.Thrombin generation was significantly enhanced in ACS compared to non-ACS patients: peak height 148±53 vs. 122±42 nM. There was a significantly diminished ETP reduction (32 vs. 41%) and increased intrinsic coagulation activation (25 vs. 7%) in ACS compared to non-ACS patients. Furthermore, compared to non-ACS patients factor XIa and D-dimer levels were significantly elevated in ACS patients: 1.9±1.1 vs. 1.4±0.7 pM and 495(310-885) vs. 380(235-540) μg/L. Within the ACS spectrum, ST-elevated myocardial infarction patients had the highest prothrombotic profile. During the acute event, thrombin generation was significantly increased compared to 1 and 6 months afterwards: peak height 145±52 vs. 100±44 vs. 98±33 nM. Both peak height and factor XIa levels on admission predicted recurrent cardiovascular events (OR: 4.9 [95%CI 1.2-20.9] and 4.5 [1.1-18.9]).ACS patients had an enhanced prothrombotic profile, demonstrated by an increased thrombin generation potential, factor XIa and D-dimer levels. This study is the first to demonstrate the positive association between factor XIa, thrombin generation and recurrent cardiovascular events

    Safety of in-hospital insertable cardiac monitor procedures performed outside the traditional settings: results from the Reveal LINQ in-office 2 international study

    No full text
    Abstract Background Historically, the majority of insertable cardiac monitor (ICM) procedures were performed in the cardiac catheterization (cath) lab, electrophysiology (EP) lab, or operating room (OR). The miniaturization of ICMs allows the procedure to be relocated within the hospital without compromising patient safety. We sought to estimate the rate of untoward events associated with procedures performed within the hospital but outside the traditional settings and to characterize resource utilization, procedure time intervals, and physician experience. Methods The Reveal LINQ in-Office 2 (RIO 2) International study was a single arm, multicenter, prospective study. Patients indicated for an ICM and willing to undergo device insertion outside the cath/EP lab or OR were eligible and followed for 90 days after insertion. Results A total of 191 patients (45.5% female aged 63.8 ± 26.9 years) underwent successful Reveal LINQ ICM insertion at 17 centers in Europe, Canada and Australia. The median total visit duration was 106 min (interquartile range [IQR]: 55–61). Patient preparation and patient education accounted for 10 min (IQR: 5–20) and 10 min (IQR: 8–15) of total visit duration, respectively. Preparation and education occurred in the procedure room for 90.6 and 60.2% of patients, respectively. There were no untoward events (0.0, 95% CI: 0.0–2.1%) though four patients presented with procedure-related adverse events that did not require invasive intervention. Physicians rated procedure location as convenient or very convenient. Conclusions The Reveal LINQ™ ICM insertion can be safely and efficiently performed in the hospital outside the cath/EP lab or OR. Trial registration ClinicalTrials.gov identifier NCT02412488 ; registered on April 9, 2015
    corecore