5 research outputs found

    Canagliflozin and Cardiovascular and Renal Events in Type 2 Diabetes

    Get PDF
    BACKGROUND Canagliflozin is a sodium–glucose cotransporter 2 inhibitor that reduces glycemia as well as blood pressure, body weight, and albuminuria in people with diabetes. We report the effects of treatment with canagliflozin on cardiovascular, renal, and safety outcomes. METHODS The CANVAS Program integrated data from two trials involving a total of 10,142 participants with type 2 diabetes and high cardiovascular risk. Participants in each trial were randomly assigned to receive canagliflozin or placebo and were followed for a mean of 188.2 weeks. The primary outcome was a composite of death from cardiovascular causes, nonfatal myocardial infarction, or nonfatal stroke. RESULTS The mean age of the participants was 63.3 years, 35.8% were women, the mean duration of diabetes was 13.5 years, and 65.6% had a history of cardiovascular disease. The rate of the primary outcome was lower with canagliflozin than with placebo (occurring in 26.9 vs. 31.5 participants per 1000 patient-years; hazard ratio, 0.86; 95% confidence interval [CI], 0.75 to 0.97; P<0.001 for noninferiority; P=0.02 for superiority). Although on the basis of the prespecified hypothesis testing sequence the renal outcomes are not viewed as statistically significant, the results showed a possible benefit of canagliflozin with respect to the progression of albuminuria (hazard ratio, 0.73; 95% CI, 0.67 to 0.79) and the composite outcome of a sustained 40% reduction in the estimated glomerular filtration rate, the need for renal-replacement therapy, or death from renal causes (hazard ratio, 0.60; 95% CI, 0.47 to 0.77). Adverse reactions were consistent with the previously reported risks associated with canagliflozin except for an increased risk of amputation (6.3 vs. 3.4 participants per 1000 patient-years; hazard ratio, 1.97; 95% CI, 1.41 to 2.75); amputations were primarily at the level of the toe or metatarsal. CONCLUSIONS In two trials involving patients with type 2 diabetes and an elevated risk of cardiovascular disease, patients treated with canagliflozin had a lower risk of cardiovascular events than those who received placebo but a greater risk of amputation, primarily at the level of the toe or metatarsal. (Funded by Janssen Research and Development; CANVAS and CANVAS-R ClinicalTrials.gov numbers, NCT01032629 and NCT01989754, respectively.

    Efficacy and safety of canagliflozin when used in conjunction with incretin-mimetic therapy in patients with type 2 diabetes

    Get PDF
    Aims: To assess the efficacy and safety of canagliflozin, a sodium glucose co-transporter 2 (SGLT2) inhibitor, in patients with type 2 diabetes enrolled in the CANagliflozin cardioVascular Assessment Study (CANVAS) who were on an incretin mimetic [dipeptidyl peptidase-4 (DPP-4) inhibitor or glucagon-like peptide-1 (GLP-1) receptor agonist]. Methods: CANVAS is a double-blind, placebo-controlled study that randomized participants to canagliflozin 100 or 300 mg or placebo added to routine therapy. The present post hoc analysis assessed the efficacy and safety of canagliflozin 100 and 300 mg compared with placebo in subsets of patients from CANVAS who were taking background DPP-4 inhibitors or GLP-1 receptor agonists with or without other antihyperglycaemic agents at week 18. Results: Of the 4330 patients in CANVAS, 316 were taking DPP-4 inhibitors and 95 were taking GLP-1 receptor agonists. At 18 weeks, canagliflozin 100 and 300 mg provided larger placebo-subtracted reductions in glycated haemoglobin (HbA1c) in patients taking DPP-4 inhibitors [-0.56% (95% confidence interval [CI]: -0.77, -0.35), and -0.75% (95% CI: -0.95, -0.54), respectively] and GLP-1 receptor agonists [-1.00% (95% CI: -1.35, -0.65), and -1.06% (95% CI: -1.43, -0.69), respectively]. Body weight and blood pressure (BP) reductions were seen with canagliflozin versus placebo in both subsets. Higher incidences of genital mycotic infections and osmotic diuresis-related adverse events (AEs) were seen with canagliflozin compared with placebo. The incidence of hypoglycaemia was numerically higher with canagliflozin versus placebo; nearly all events occurred in patients on background insulin or insulin secretagogues. Conclusions: In patients on background incretin mimetics, canagliflozin improved HbA1c, body weight and BP, with an increased incidence of AEs related to SGLT2 inhibition

    Atrasentan and renal events in patients with type 2 diabetes and chronic kidney disease (SONAR): a double-blind, randomised, placebo-controlled trial

    Get PDF
    Background: Short-term treatment for people with type 2 diabetes using a low dose of the selective endothelin A receptor antagonist atrasentan reduces albuminuria without causing significant sodium retention. We report the long-term effects of treatment with atrasentan on major renal outcomes. Methods: We did this double-blind, randomised, placebo-controlled trial at 689 sites in 41 countries. We enrolled adults aged 18–85 years with type 2 diabetes, estimated glomerular filtration rate (eGFR)25–75 mL/min per 1·73 m 2 of body surface area, and a urine albumin-to-creatinine ratio (UACR)of 300–5000 mg/g who had received maximum labelled or tolerated renin–angiotensin system inhibition for at least 4 weeks. Participants were given atrasentan 0·75 mg orally daily during an enrichment period before random group assignment. Those with a UACR decrease of at least 30% with no substantial fluid retention during the enrichment period (responders)were included in the double-blind treatment period. Responders were randomly assigned to receive either atrasentan 0·75 mg orally daily or placebo. All patients and investigators were masked to treatment assignment. The primary endpoint was a composite of doubling of serum creatinine (sustained for ≥30 days)or end-stage kidney disease (eGFR <15 mL/min per 1·73 m 2 sustained for ≥90 days, chronic dialysis for ≥90 days, kidney transplantation, or death from kidney failure)in the intention-to-treat population of all responders. Safety was assessed in all patients who received at least one dose of their assigned study treatment. The study is registered with ClinicalTrials.gov, number NCT01858532. Findings: Between May 17, 2013, and July 13, 2017, 11 087 patients were screened; 5117 entered the enrichment period, and 4711 completed the enrichment period. Of these, 2648 patients were responders and were randomly assigned to the atrasentan group (n=1325)or placebo group (n=1323). Median follow-up was 2·2 years (IQR 1·4–2·9). 79 (6·0%)of 1325 patients in the atrasentan group and 105 (7·9%)of 1323 in the placebo group had a primary composite renal endpoint event (hazard ratio [HR]0·65 [95% CI 0·49–0·88]; p=0·0047). Fluid retention and anaemia adverse events, which have been previously attributed to endothelin receptor antagonists, were more frequent in the atrasentan group than in the placebo group. Hospital admission for heart failure occurred in 47 (3·5%)of 1325 patients in the atrasentan group and 34 (2·6%)of 1323 patients in the placebo group (HR 1·33 [95% CI 0·85–2·07]; p=0·208). 58 (4·4%)patients in the atrasentan group and 52 (3·9%)in the placebo group died (HR 1·09 [95% CI 0·75–1·59]; p=0·65). Interpretation: Atrasentan reduced the risk of renal events in patients with diabetes and chronic kidney disease who were selected to optimise efficacy and safety. These data support a potential role for selective endothelin receptor antagonists in protecting renal function in patients with type 2 diabetes at high risk of developing end-stage kidney disease. Funding: AbbVie

    International Large Detector: Interim Design Report

    No full text
    The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design and eventually propose a fully integrated detector, primarily for the International Linear Collider, ILC. In this report the fundamental ideas and concepts behind the ILD detector are discussed and the technologies needed for the realisation of the detector are reviewed. The document starts with a short review of the science goals of the ILC, and how the goals can be achieved today with the detector technologies at hand. After a discussion of the ILC and the environment in which the experiment will take place, the detector is described in more detail, including the status of the development of the technologies foreseen for each subdetector. The integration of the different sub-systems into an integrated detector is discussed, as is the interface between the detector and the collider. This is followed by a concise summary of the benchmarking which has been performed in order to find an optimal balance between performance and cost. To the end the costing methodology used by ILD is presented, and an updated cost estimate for the detector is presented. The report closes with a summary of the current status and of planned future actions

    The ILD detector at the ILC

    No full text
    The International Large Detector, ILD, is a detector concept which has been developed for the electron-positron collider ILC. The detector has been optimized for precision physics in a range of energies between 90 GeV and 1 TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a 3.5 T solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. In this document the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed. This is done in the framework of the ILC collider proposal, now under consideration in Japan, and includes site specific aspects needed to build and operate the detector at the proposed ILC site in Japan
    corecore