110 research outputs found

    Predictors of hyperamylasemia in patients with cholecystolithiasis after laparoscopic cholecystolithotomy with intraoperative dosed endoscopic papillotomy

    Get PDF
    The purpose of the work is to improve the early and long-term results of patients with cholecystolithiasis treatment by supplementing cholecystolithotomy with one-stage intraoperative dosed endoscopic papillosphincterotomy (EPST) and predictors of increased risk of transient hyperamylasemia after EPST identification. Material and methods. 33 patients with cholecytholithiasis were involved in the study, the average age was 46.82 ± 13.02 years, women 27 (82 %), body mass index 28.56 ± 5.85 kg/m2. We studied intraoperative, early postoperative complications and long-term results. The follow-up period of patients with cholecystolithiasis after cholecystolithotomy with intraoperative dosed endoscopic papillotomy was 1424 days (3.9 years), median follow-up – 467 days. The odds ratio was calculated using logistic regression analysis. Results. Intraoperative and early postoperative complications were not observed. During the endoscopic papillotomy and in the early postoperative period no serious complications (duodenal perforations, bleeding, pancreatitis (pancreatic necrosis)) were observed. Transient hyperamylasemia occurred in 4 (12.12 %) out of the 33 patients with choledocholithiasis who were performed laparoscopic cholecystolithotomy with intraoperative papillotomy in the first day after surgery. According to the logistic regression, the choledochus ascending diameter increase more than4.2 mm (HS = 2.31; 95% CI 1.02–6.11; P = 0.0483) is associated with transient amylasemia. One case of acute non-calculous cholecystitis requiring the surgical intervention (laparoscopic cholecystectomy) was registered during 3.9 years of follow-up. Recurrence of cholecystocholedocholithiasis and major duodenal papilla stenosis occurred in no case. Conclusions. Laparoscopic cholecystolithotomy supplemented with one-stage intraoperative dosed endoscopic papillotomy performed according to absolute indications, are safe and highly effective surgical intervention, which allows preserving the gall bladder, restoring its motor-evacuator and concentration functions, and preventing recurrence of cholecystocholedocholithiasis by restoring bile outflow to the duodenum. Transient hyperamylasemia occurred in the first day after operation in 12.12 % (4/33) patients with cholecystolithiasis, who were performed laparoscopic cholecystolithotomy with intraoperative endoscopic papillotomy. The predictor of transient hyperamylasemia after cholecystolithotomy with intraoperative dosed endoscopic papillotomy in patients with cholecystolithiasis is the ascending choledochus diameter increase more than4.2 mm (VS = 2.31; 95 % CI 1.02–6.11; P = 0.0483)

    Перешкодостійке кодування повідомлення електронного підпису

    Get PDF
    Work was carried out on the study and selection of radio links, algorithms for the formation and processing of electronic signatures. Functional blocks, which allow the possibility to carry out the transmission of the electronic signature on the radio communication lines are developed. Computational experiments were carried out to determine the characteristics of the electronic signature notification, in which high impedance is achieved.Проведена работа по изучению и выбору радиолиний связи, алгоритмов формирования и обработки электронной подписи. Разработаны функциональные блоки, которые дают возможность осуществлять передачу электронной подписи по радиолиниям связи. Проведены вычислительные эксперименты для определения характеристик сообщения электронной подписи, при которых достигается высокая помехоустойчивость.Проведено роботу з вивчення і обрання радіоліній зв’язку, алгоритмів формування і обробки електронного підпису. Розроблено функціональні блоки, які дають можливість здійснювати передачу електронного підпису по радіолініях зв’язку. Проведено обчислювальні експерименти для визначення характеристик повідомлення електронного підпису, при яких досягається висока перешкодостійкість

    Новое конструкционное решение проблемы совершенствования аппаратов биологической очистки сточных вод

    Get PDF
    Зазначено актуальність проблеми модернізації діючих міських очисних споруд у зв’язку із скороченням об’ємів стічних вод, які скидаються населенням України. Показано, що біологічний метод очищення є основним для більшості очисних споруд. Метою даної роботи є удосконалення існуючих апаратів біологічного очищення міських стічних вод задля їх обробки при скороченні об’ємів стоків, що подаються населенням. Проаналізовано класичну схему біологічного очищення стічних вод, згідно якої час перебування стоків в первинному та вторинному відстійниках перевищує проектне значення більш як у 3 рази, а в аеротенках – у 2,7. Розроблено та наведено нову конструкцію комбінованого аеротенка-відстійника, особливістю якого є компактність та можливість застосування для невеликих об’ємів стоків. Запропоновано удосконалену технологію біологічного очищення стічних вод із використанням аеротенка-відстійника, яку рекомендовано застосовувати на більшості міських очисних споруд України.Relevance of modernizing existing municipal wastewater treatment plants in connection with reduction of volumes wastewater discharged by the population of Ukraine is indicated. It is shown that the biological method is preferred for most treatment plants. The aim of this work was to improve the existing units for biological treatment of municipal wastewater for providing the population. The classical scheme of biological wastewater treatment according to which the residence time of wastewater in the primary and secondary sedimentation tanks exceeds the design value by more than 3 times, and in aeration tanks in 2,7 was analyzed. New design of the combined aerotank-settler (compact and possible for use for small volumes of wastewater) were developed and presented. An offered technology for biological wastewater treatment using aerotank-settler can be recommended for most municipal treatment plants of Ukraine.Обозначена актуальность проблемы модернизации действующих городских очистных сооружений в связи с сокращением объемов сточных вод, которые сбрасываются населением Украины. Показано, что биологический метод очистки является основным для большинства очистных сооружений. Целью данной работы является совершенствование существующих аппаратов биологической очистки городских сточных вод для их обработки при сокращении объемов стоков, которые поступают от населения. Проанализирована классическая схема биологической очистки сточных вод, согласно которой время пребывания стоков в первичном и вторичном отстойниках превышает проектное значение более чем в 3 раза, а в аэротенках – в 2,7. Разработана и приведена новая конструкция комбинированного аэротенка-отстойника, особенностью которого является компактность и возможность применения для небольших объемов стоков. Предложена усовершенствованная технология биологической очистки сточных вод с использованием аэротенка-отстойника, которую рекомендуется применять на большинстве городских очистных сооружений Украины

    Operation of a quantum dot in the finite-state machine mode: single-electron dynamic memory

    Full text link
    A single electron dynamic memory is designed based on the non-equilibrium dynamics of charge states in electrostatically-defined metallic quantum dots. Using the orthodox theory for computing the transfer rates and a master equation, we model the dynamical response of devices consisting of a charge sensor coupled to either a single and or a double quantum dot subjected to a pulsed gate voltage. We show that transition rates between charge states in metallic quantum dots are characterized by an asymmetry that can be controlled by the gate voltage. This effect is more pronounced when the switching between charge states corresponds to a Markovian process involving electron transport through a chain of several quantum dots. By simulating the dynamics of electron transport we demonstrate that the quantum box operates as a finite-state machine that can be addressed by choosing suitable shapes and switching rates of the gate pulses. We further show that writing times in the ns range and retention memory times six orders of magnitude longer, in the ms range, can be achieved on the double quantum dot system using experimentally feasible parameters thereby demonstrating that the device can operate as a dynamic single electron memory.Comment: 18 pages, 8 figure

    CHALLENGES OF DYNAMIC SIMULATION OF HIGH-SPEED ELECTROMAGNETIC VALVES OF GAS DISTRIBUTION DEVICES

    Get PDF
    High-speed electromagnetic valves of gas distribution devices are used in modern missile and space technology as jet micro-motors of the executive elements of missile stabilization systems, as well as to control the movement of spacecrafts in space. The problem of creating such valves which are simple and reliable in the operation is relevant. In this work, it is proposed at the development and design stage to perform computer modelling of mutually coupled electromechanical processes, such as: distribution of transient electromagnetic field, transients in an electric circuit, and movement of an electromagnet armature. Besides, the calculation of the force with which the compressed gas acts on the corresponding structural elements of the valve is proposed to be performed by solving the system of Navier-Stokes equations. All problems are solved by numerical methods in axisymmetrical formulation with the corresponding initial and boundary conditions. Improvement of the accuracy of electromagnetic calculations and taking into account the movement of the armature of an electromagnet in the process of multiphysics numerical simulation is achieved using so-called tunable elastic meshes. The paper presents a comparative analysis of the numerical results obtained for several designs of electromagnets. The features of the dynamics of high-speed electromagnets of gas distribution valves during on and off operations are analyzed, the corresponding dynamic characteristics calculated using the proposed technique are presented. Быстродействующие электромагнитные клапаны газораспределительных устройств применяются в современной ракетно-космической технике в качестве реактивных микродвигателей исполнительных органов систем стабилизации ракет, а также для управления движением космическими летательными аппаратами в пространстве. Проблема создания простых в эксплуатации и надежных в работе указанных клапанов является актуальной. В настоящей работе предлагается на стадии разработки и проектирования выполнять компьютерное моделирование взаимосвязанных электромеханических процессов, таких как: распределение нестационарного электромагнитного поля, переходные процессы в электрической цепи, движение якоря электромагнита. При этом расчет силы, с которой сжатый газ действует на соответствующие конструктивные элементы клапана, предлагается выполнять путем решения системы уравнений Навье-Стокса. Все задачи решаются численными методами в осесимметричной постановке с соответствующими начальными и граничными условиями. Повышение точности электромагнитных расчетов и учет движения якоря электромагнита в процессе мультифизического численного моделирования достигается благодаря использованию так называемых перестраиваемых упругих сеток. В работе приведен сравнительный анализ численных результатов, полученных для нескольких конструкций электромагнитов. Проанализированы особенности динамики быстродействующих электромагнитов газораспределительных клапанов при выполнении операций включения и отключения, приведены соответствующие динамические характеристики, рассчитанные по предложенной методике.

    СПОСІБ РОЗРАХУНКУ ЛОКАЛІЗАЦІЇ ДЖЕРЕЛА ШУМІВ У ТРИВИМІРНОМУ ПРОСТОРІ ДЛЯ ДІАГНОСТИКИ ПНЕВМОНІЇ У ДІТЕЙ МОЛОДШОГО ВІКУ

    Get PDF
    The theoretical justification for using of the GPS-technology principle for the pneumonia diagnosis was made in the article. The sensor's matrix is located on a patient's chest and it's an inactive system's component unlike satellites used in GPS. The method is i mplemented using t he GPS-navigation formula with some variables replacements. For determining of the coordinates of the sounds source in the three-dimensional space it's necessary to calculate time from sound's source to each sensor of matrix. According to the obtained coordinates the conclusion about the depth and location of the inflammation process (pneumonia) in the patient lungs can be made.В статье теоретически обосновано использование принципа GPS-технологии для диагностики пневмоний. Матрица датчиков, располагающаяся на грудной клетке пациента, является неактивной составляющей системы, в отличие от спутников, которые использован ы в GPS. Способ реализуется при помощи уравнений GPS-навигации, в которых производится замена переменных. Рассчитывая время прихода респираторного аускультативного шума к каждому из датчиков матрицы получают координаты источника воспалительного процесса в трёхмерном пространстве. По полученным координатам делают вывод о глубине и месте положения воспалительного процесса (пневмонии) в лёгких пациента.У статті теоретично обґрунтоване використання принципу GPS-технології для діагностики пневмоній. Матриця датчиків, розташована на грудній клітці пацієнта, є неактивною складовою системи, на відміну від супутників, що використовуються у GPS. Спосіб реалізується за допомогою рівнянь GPS-навігації, у яких замінюються змінні. Розраховуючи час приходу респіраторного аускультативного шуму до кожного з датчиків матриці отримують координати джерела запального процесу у тривимірному просторі. За отриманими координатами роблять висновок про глибину та місце положення запального процесу (пневмонії) у легенях пацієнта

    СИСТЕМА ДЛЯ РЕАЛІЗАЦІЇ МЕТОДА ДІАГНОСТИКИ ПНЕВМОНІЙ ПАСИВНОЮ ЕХОЛОКАЦІЄЮ

    Get PDF
    The article describes the design of equipment for implementing the method of diagnosis of pneumonia by the method of passive echolocation. Diagnosis is done through listening, identify and determine the place of the provisions of pathological noise sources in the respiratory system of the patient. The device is specially designed for implementation of the method of diagnosis of pneumonia by the method of passive echolocation and tested. The recordings of acoustic signals of respiratory pattern are of high quality, the device itself is convenient and easy to use.В статье описана конструкция оборудования для реализации способа диагностики пневмонии методом пассивной эхолокации. Диагностика осуществляется благодаря прослушиванию, идентификации и выявлению местоположения источников патологических шумов в дыхательной системе пациента. Устройство разработано специально для реализации способа диагностики пневмонии методом пассивной эхолокации и испытано. Полученные записи акустических сигналов дыхательного паттерна имеют высокое качество, само устройство удобно и просто в использовании.У статті описано конструкцію обладнання для реалізації способу діагностики пневмонії методом пасивної ехолокації. Діагностика здійснюється завдяки прослуховуванню, ідентифікації та виявленню місця положення джерел патологічних шумів у дихальній системі пацієнта. Пристрій розроблено спеціально для реалізації способу діагностики пневмонії методом пасивної ехолокації та випробувано. Отримані записи акустичних сигналів дихального патерну мають високу якість, сам пристрій зручний та простий у використанні

    Патоморфологічні зміни в паренхіматозних органах кролів за хро-нічного перебігу пасалурозу

    Get PDF
    Pathomorphological changes, developing in case of pasalurosis chronic course in rabbits are described in the article. The research was held on ten rabbits of Large Grey breed, which were held on household farms of Poltava region. The diagnosing was complex: based on anamnesis data, clinical symptoms’ analysis, and the results of pathomorphological examination. The fragments of the liver, spleen, and kidneys were taken for histological analysis. While making histological analysis of the spleen it was revealed that lymphoid nodules were enlarged, some of them were of uniform structure, and others were in the state of hyperplasia. Non-uniformity of structure in addition to changing the size was registered in those nodules: there was less concentration of lymphoid cells in their central part and more concentration on the periphery. The situation was contrary in separate lymphoid nodules. The red pulp consisted of a large number of lymphoid cells and erythrocytes, the largest number of which were registered in the zones adjoining the places of lymphoid nodules’ location. Sometimes there were megakaryocytes in the field of vision. It was established, that blood filling of arteries was less than normal. In case of using some preparations, bilirubin inclusions were found at having big enlargements in red pulp. Grainy and fatty hepatocytes’ dystrophies, and also lymphohistiocytic interstitial hepatitis were also registered. At the same time, renal corpuscles were enlarged. Rather big spaces, filled with transparent substance containing vessel and cellular fragments (detritus), were revealed in the majority of them between glomeruli and the capsule.Capsule epithelial cells were destroyed in some places. Petechial hemorrhages were registered inside glomeruli. The destruction of separate podocytes and deep cells was noticed. The tubular epithelial cells were enlarged in size, and in some cases they were of cylinder, but not cubic shape; the spaces of such tubular were becoming correspondingly less. The epithelial cell cytoplasm of the tubular in some cases was not uniformand it was of cloudy-grey color: in other cases it had rather large colorless areas and, probably, looked like lipid inclusions (which were washed out from the cells as a result solvent impact during making histological preparations). Concentrations of eosinophilic masses (protein cylinders) sometimes containing certain amount of erythrocytes were often found in canaliculi spaces. Sometimes the destruction of epithelial cells was registered in the tubulеs, and their fragments were found in spaces. As a result of histological examination, the diffuse lymphohistiocytic infiltration in the renal interstitial tissue was found.У статті описано патоморфологічні зміни, що розвиваються за хронічного перебігу пасалурозу кролів. Дослідження проведено на 10 кролях породи сірий велетень, які утримувались у домашніх умовах в одноосібних господарствах Полтавської області. Діагноз встановлено комплексно: на основі даних анамнезу, аналізу клінічних ознак, результатів патолого-анатомічного дослідження. Для мікроскопії відібрано зразки печінки, селезінки та нирок. За гістологічного дослідження селезінки встановлено, що лімфоїдні вузлики збільшені в розмірах, деякі з них мали однорідну будову, деякі були в стані гіперплазії. В таких вузликах, окрім змін в розмірах, зареєстровано неоднорідність структури: в центральній їхній частині виявлено меншу концентрацію лімфоїдних клітин, по периферії – більшу концентрацію. В окремих лімфоїдних вузликах – навпаки. Червона пульпа складалася з великої кількості лімфоїдних клітин та еритроцитів, найбільшу кількість яких зафіксовано у зонах, що прилягали до місць розташування лімфоїдних вузликів. Подекуди в полі зору траплялися мегакаріоцити. Встановлено, що кровонаповнення артерій менше, ніж у нормі. На деяких препаратах за великих збільшень в червоній пульпі виявлено включення білірубіну. Також реєстрували зернисту й жирову дистрофії гепатоцитів та лімфогістіоцитарний інтерстиційний гепатит. Водночас ниркові тільця збільшені в розмірах. У більшості з них між судинними клубочками та капсулою виявлено досить великі простори, заповнені прозорою субстанцією, що містила фрагменти судин та клітин (детрит). Епітеліоцити капсули подекуди зруйновані. Всередині клубочків зареєстровано крапкові крововиливи. Спостерігали руйнування окремих подоцитів та мезангіоцитів. Епітеліоцити канальців збільшені в розмірах і подекуди мали не кубічну, а циліндричну форму, просвіти таких канальців відповідно зменшені. Цитоплазма епітеліоцитів канальців в одних випадках була неоднорідною, мутно-сірою; в інших – мала досить великі ділянки, які не зафарбовувалися і, вочевидь, являли собою включення ліпідів (які вимиваються з клітин внаслідок дії розчинників під час виготовлення гістопрепаратів). У просвітах канальців часто виявляли скупчення еозинофільної маси (білкові циліндри), які інколи містили й певну кількість еритроцитів. Іноді в канальцях спостерігали руйнування епітеліоцитів, фрагменти яких містилися в просвіті. Гістологічним дослідженням встановлено наявність дифузної лімфогістіоцитарної інфільтрації в інтерстиційній тканині нирок

    Metody rehabilitacji ruchowej i psychologicznej policjantów w warunkach ich aktywności służbowej

    Get PDF
    Means of police officers’ physical and psychological rehabilitation in the conditions of their service activities / V. Bondarenko, I. Okhrimenko, N. Lyakhova, I. Klymenko, D. Shvets, Y. Aleksandrov // Acta Balneologica. – 2021. – Num. 4 (166), Т. LXIII. – С. 273-278. – DOI: https://doi.org/10.36740/ABAL202104105.Визначені негативні фактори службової діяльності працівників поліції та теоретично обґрунтувані наявні засоби фізичної та психологічної реабілітації працівників поліції в умовах їх службової діяльності. Висновки: Встановлено, що негативні фактори службової діяльності працівників поліції в сукупності призводять до стомлення, надмірної стомлюваності, призводять до погіршення фізичної працездатності, психічного стану та потребують застосування засобів фізичної та психологічної реабілітації.To determine the negative factors of police officers’ service activities and to theoretically substantiate the available means of policeofficers’ physical and psychological rehabilitation in the conditions of their service activities.Materials and Methods_To analyse the peculiarities of police service activities, we conducted the survey of police officers (n=237) of variousstructural units of the National Police of Ukraine. The expert assessment was conducted in order to determine the effective means of policeofficers’ physical and psychological rehabilitation, which involved 18 experts. The research was conducted in 2016-2021.Results_ Negative factors were identified that lead to a deterioration in police officers’ service activities, including_ overtime at work, frequentinvolvement in public safety and public order maintenance, day’s duties, frequent injuries and injurious effects during the detention of offendersand other events. The expert survey of the specialists involved in professional training, medical examination, psychological support of policeofficers showed that pedagogical (33.2%), physical (39.6%), psychological (39.2%) means are highly effective in police officers’ physical andpsychological rehabilitation.Conclusions_ It was found that the negative factors of police officers’ service activities collectively result in fatigue, excessive fatigue, lead todeterioration of physical working ability, mental status and require introduction of physical and psychological rehabilitation means_Определены негативные факторы служебной деятельности работников полиции и теоретически обоснованы средства физической и психологической реабилитации работников полиции в условиях их служебной деятельности. Установлено, что негативные факторы служебной деятельности работников полиции в совокупности приводят к утомлению, излишней утомляемости, приводят к ухудшению физической работоспособности, психического состояния и требуют применения средств физической и психологической реабилитации

    ОСОБЕННОСТИ УПРАВЛЕНИЯ ЭЛЕКТРОПНЕВМАТИЧЕСКИМИ КЛАПАНАМИ ИСПОЛНИТЕЛЬНОГО МЕХАНИЗМА УПРАВЛЕНИЯ СЦЕПЛЕНИЕМ С УСКОРИТЕЛЬНЫМ КЛАПАНОМ

    Get PDF
    The article deals with one of the ways to control an actuator of the automated clutch control system. The aim is to design control of the electropneumatic actuator, to control its coupling with the acceleration valve on the basis of experimental research as well as to provide rational parameters of the automated clutch control system for the robotic transmission. The feature of the system is an acceleration valve in the design of the electropneumatic actuator to control the clutch. New links demand to adjust the way to control the actuator. The connection of Pulse-Width Modulation (PWM) with single power supply pulses to control electropneumatic valves is substantiated. The quantitative characteristics of single control pulses and PWM ones are determined. The error of operation accuracy for various ways of the control of the electropneumatic actuator to control the clutch of the robotic transmission is determined. Obtained separate PWM area is designed to suppress the initial hysteresis when the rod of the clutch actuator is moved. An algorithm for the operation of a clutch control system is proposed, taking into account the use of two modes of operation of solenoid valves. A graphical interpretation of the clutch control algorithm is presented, which gives an idea of the location of the constant signal feeding zones to the solenoid valve, as well as the operation areas of the solenoid valve in PWM mode. The control algorithm of the clutch booster provides a mode of guaranteed absence of excess pressure in the pneumatic cylinder after releasing the clutch pedal, provided that two normally closed solenoid valves are used. This configuration of the electro-pneumatic clutch control system allows the use of an emergency clutch release system in case of voltage absence. The reference algorithm for filtering the array of data coming from the feedback sensor, as well as the numerical values of the delay caused by the presence of a filter, are given.В статье рассмотрен один из способов управления исполнительным механизмом автоматизированной системы управления сцеплением. На основе экспериментальных исследований предложены способ управления электропневматическим исполнительным устройством управления сцеплением с ускорительным клапаном, а также рациональные параметры автоматизированной системы управления сцеплением для роботизированной трансмиссии. Особенностью рассматриваемой системы является наличие в конструкции электропневматического исполнительного механизма управления сцеплением ускорительного клапана. Наличие новых связей требует корректировки способа управления исполнительным механизмом. Обосновано объединение широтно-импульсной модуляции с одиночными импульсами питания для управления электропневматическими клапанами. Определены количественные характеристики управляющих импульсов как для случая одиночных, так и в случае использования широтно-импульсной модуляции. Определена ошибка точности работы во время разных способов управления электропневматическим исполнительным устройством управления сцеплением роботизированной трансмиссии. Выделена отдельная зона широтно-импульсной модуляции, предназначенная для подавления начального гистерезиса при перемещении штока исполнительного устройства управления сцеплением. Предложен алгоритм работы системы управления сцеплением с учетом использования двух режимов работы электромагнитных клапанов. Представлена графическая интерпретация алгоритма управления сцеплением, дающая представление о расположении зон подачи постоянного сигнала на электромагнитный клапан, а также зон работы электромагнитного клапана в режиме широтно-импульсной модуляции. В алгоритме управления усилителем предусмотрен режим гарантированного сброса давления из пневматического цилиндра после отпускания педали сцепления при условии использования двух нормально закрытых электромагнитных клапанов. Такая конфигурация электропневматической системы управления сцеплением позволяет задействовать систему аварийного выключения сцепления при отсутствии электропитания. Приведены опорный алгоритм фильтрации массива данных, поступающих от датчика обратной связи, а также численные значения запаздывания, вызванного наличием фильтра
    corecore