149 research outputs found

    Passive mode locking of a Tm,Ho:KY(WO4)(2) laser around 2 ÎŒm

    Get PDF
    We report the first demonstration, to our knowledge, of passive mode locking in a Tm3+, Ho3+-codoped KYWO42 laser operating in the 2000-2060 nm spectral region. An InGaAsSb-based quantum well semiconductor saturable absorber mirror is used for the initiation and stabilization of the ultrashort pulse generation. Pulses as short as 3.3 ps were generated at 2057 nm with average output powers up to 315 mW at a pulse repetition frequency of 132 MHz for 1.15 W of absorbed pump power at 802 nm from a Ti:sapphire laser

    Peak flow measurements in patients with severe aortic stenosis : a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography

    Get PDF
    Background Aortic valve stenosis (AS) is the most prevalent valvular disease in the developed countries. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is an emerging imaging technique, which has been suggested to improve the evaluation of AS severity compared to two-dimensional (2D) flow and transthoracic echocardiography (TTE). We investigated the reliability of CMR 2D flow and 4D flow techniques in measuring aortic transvalvular peak systolic flow in patients with severe AS. Methods We prospectively recruited 90 patients referred for aortic valve replacement due to severe AS (73.3 +/- 11.3 years, aortic valve area 0.7 +/- 0.1 cm(2), and 54/36 tricuspid/bicuspid), and 10 non-valvular disease controls. All the patients underwent echocardiography and 2D flow and 4D flow CMR. Peak flow velocity measurements were compared using Wilcoxon signed rank sum test and Bland-Altman analysis. Results 4D flow underestimated peak flow velocity in the AS group when compared with TTE (bias - 1.1 m/s, limits of agreement +/- 1.4 m/s) and 2D flow (bias - 1.2 m/s, limits of agreement +/- 1.6 m/s). The differences between values obtained by TTE (median 4.3 m/s, range 2.7-6.1 m/s) and 2D flow (median 4.5 m/s, range 2.9-6.5 m/s) compared to 4D flow (median 3.1 m/s, range 1.7-5.1 m/s) were significant (p < 0.001). The difference between 2D flow and TTE were insignificant (bias 0.07 m/s, limits of agreement +/- 1.5 m/s). In non-valvular disease controls, peak flow velocity was measured higher by 4D flow than 2D flow (1.4 m/s, 1.1-1.7 m/s and 1.3 m/s, 1.1-1.5 m/s, respectively; bias 0.2 m/s, limits of agreement +/- 0.16 m/s). Conclusions CMR 4D flow significantly underestimates systolic peak flow velocity in patients with severe AS. 2D flow, in turn, estimated the AS velocity accurately, with measured peak flow velocities comparable to TTE.Peer reviewe

    Bombali Virus in Mops condylurus Bat, Kenya

    Get PDF
    Bombali virus (genus Ebolavirus) was identified in organs and excreta of an Angolan free-tailed bat (Mops condylurus) in Kenya. Complete genome analysis revealed 98% nucleotide sequence similarity to the prototype virus from Sierra Leone. No Ebola virus-specific RNA or antibodies were detected from febrile humans in the area who reported contact with bats.Peer reviewe

    Fixation of osteochondral fragments in the human knee using Meniscus ArrowsÂź

    Get PDF
    The aim of this study is to compare the hold in bone of Meniscus ArrowsŸ and Smart NailsŸ, followed by the report of the results of the clinical application of Meniscus ArrowsŸ as fixation devices. First, pull-out tests were performed to analyse the holdfast of both nails in bone. Statistical analysis showed no significant difference; therefore, the thinner Meniscus ArrowŸ was chosen as fixation device in the patient series of two patients with a symptomatic Osteochondritis dissecans fragment and three patients with an osteochondral fracture of a femur condyle. The cartilage margins were glued with TissuecollŸ. All fragments consolidated. Second look arthroscopy in three patients showed fixed fragments with stable, congruent cartilage edges. At an average follow-up period of 5 years no pain, effusion, locking, restricted range of motion or signs of osteoarthritis were reported. Based on the results of the pull-out tests and available clinical studies, Meniscus ArrowsŸ and Smart NailsŸ are both likely to perform adequately as fixation devices in the treatment of Osteochondritis dissecans and osteochondral fractures in the knee. They both provide the advantage of one stage surgery. However, based on their smaller diameter, the Meniscus ArrowsŸ should be preferred for this indication

    In the Shadow of Celebrity? World-Class University Policies and Public Value in Higher Education

    Get PDF
    The growing popularity of the concept of world-class universities raises the question of whether investing in such universities is a worthwhile use of public resources. Does concentrating public resources on the most excellent universities improve the overall quality of a higher education system, especially if definitions of excellence and world-class are made by external ranking organizations? This paper addresses that question by developing a framework for weighing up trade-offs between institutional and system performance, focusing on the potential system-wide improvements which world-class university programmes (WCUPs) may bring. Because WCUPs are in a relatively early stage of their development, systemic effects are not yet clear. We therefore analyse the ex ante reasons that policy makers have for adopting WCUPs to see if they at least seek to create these systemic benefit

    Revealing the nature of morphological changes in carbon nanotube-polymer saturable absorber under high-power laser irradiation

    Get PDF
    Composites of single-walled carbon nanotubes (SWNTs) and water-soluble polymers (WSP) are the focus of significant worldwide research due to a number of applications in biotechnology and photonics, particularly for ultrashort pulse generation. Despite the unique possibility of constructing non-linear optical SWNT-WSP composites with controlled optical properties, their thermal degradation threshold and limit of operational power remain unexplored. In this study, we discover the nature of the SWNT-polyvinyl alcohol (PVA) film thermal degradation and evaluate the modification of the composite properties under continuous high-power ultrashort pulse laser operation. Using high-precision optical microscopy and micro-Raman spectroscopy, we have examined SWNT-PVA films before and after continuous laser radiation exposure (up to 40 hours) with a maximum optical fluence of 2.3 mJ·cm−2. We demonstrate that high-intensity laser radiation results in measurable changes in the composition and morphology of the SWNT-PVA film due to efficient heat transfer from SWNTs to the polymer matrix. The saturable absorber modification does not affect the laser operational performance. We anticipate our work to be a starting point for more sophisticated research aimed at the enhancement of SWNT-PVA films fabrication for their operation as reliable saturable absorbers in high-power ultrafast lasers

    Current state and future of pediatric allergology in Europe: A road map

    Get PDF
    The history of pediatric allergology (PA) in Europe is relatively youthful, dating back to 1984, when a small group of pediatricians founded the European Working Group on Pediatric Allergy and Immunology—later giving rise to ESPACI (European Society on Pediatric Allergology and Clinical Immunology). In 1990, the first dedicated journal, Pediatric Allergy and Immunology (PAI), was founded. There are striking differences across Europe, and even within European countries, in relation to the training pathways for doctors seeing children with allergic disease(s). In 2016, the EAACIClemens von Pirquet Foundation (CvP) organized and sponsored a workshop with the European Academy of Allergy and Clinical Immunology (EAACI) Pediatric Section. This collaboration focussed on the future of PA and specifically on education, research, and networking/ advocacy. The delegates representing many countries across Europe have endorsed the concept that optimal care of children with allergic diseases is delivered by pediatricians who have received dedicated training in allergy, or allergists who have received dedicated training in pediatrics. In order to meet the needs of children and families with allergic disease(s), the pediatric allergist is highly encouraged to develop several networks. Our challenge is to reinforce a clear strategic approach to scientific excellence to across our member base and to ensure and enhance the relevance of European pediatric research in allergy. With research opportunities in basic, translational, clinical, and epidemiologic trials, more trainees and trained specialists are needed and it is an exciting time to be a pediatric allergologist
    • 

    corecore