23 research outputs found

    Reducing discomfort while measuring crown Á heel length in neonates

    Get PDF
    Abstract Aim: To assess the degree of discomfort caused by length measurement in neonates, performed with one or both lower limbs extended, on the first and second day after birth, with either one or both lower limbs extended. Methods: Healthy full-term neonates were systematically sampled during the months of February and March 2004. Crown Áheel length was measured, using a 1-mm precision neonatometer, at approximately 8 h and 32 h after birth, with one and both lower limbs extended. The Neonatal Facial Coding System was used to assess discomfort during measurements. Data were analysed by parametric and non-parametric tests as appropriate. Results: Whatever the measurement technique, discomfort scores are significantly higher during the length measurement than at baseline. Whenever length measurements are performed, discomfort scores are significantly higher when extending both lower limbs rather than one lower limb (p B/0.006). The measured length is greater with one lower limb extended; however, the difference decreases over time, being 0.19 cm (95% CI 0.1 Á0.3; p B/0.001) at approximately 32 h of age. No significant differences in length were found between measurements at approximately 8 or 32 h, regardless of the technique used. The best correlation between length measurements with one or both lower limbs extended was observed at approximately 32 h after birth (r 0/0.98). Conclusion: Measuring crown Áheel length is a distressful procedure for the neonate. Measurements with one lower limb extended result in less discomfort than when both lower limbs are extended, without decreasing the accuracy

    Analytical protocols for separation and electron microscopy of nanoparticles interacting with bacterial cells

    Get PDF
    An important step toward understanding interactions between nanoparticles (NPs) and bacteria is the ability to directly observe NPs interacting with bacterial cells. NPbacteria mixtures typical in nanomedicine, however, are not yet amendable for direct imaging in solution. Instead, evidence of NPcell interactions must be preserved in derivative (usually dried) samples to be subsequently revealed in high-resolution images, e.g., via scanning electron microscopy (SEM). Here, this concept is realized for a mixed suspension of model NPs and Staphylococcus aureus bacteria. First, protocols for analyzing the relative colloidal stabilities of NPs and bacteria are developed and validated based on systematic centrifugation and comparison of colony forming unit (CFU) counting and optical density (OD) measurements. Rate-dependence of centrifugation efficiency for each component suggests differential sedimentation at a specific predicted rate as an effective method for removing free NPs after co-incubation; the remaining fraction comprises bacteria with any associated NPs and can be examined, e.g., by SEM, for evidence of NPbacteria interactions. These analytical protocols, validated by systematic control experiments and high-resolution SEM imaging, should be generally applicable for investigating NPbacteria interactions.financial support from the following sources: grant SFRH/BPD/47693/2008 from the Portuguese Foundation for Science and Technology (FCT); FCT Strategic Project PEst-OE/EQB/LA0023/2013; project “BioHealth Biotechnology and Bioengineering approaches to improve health quality”, Ref. NORTE-07-0124-FEDER-000027, cofunded by the Programa Operacional Regional do Norte (ON.2−O Novo Norte), QREN, FEDER; project “Consolidating Research Expertise and Resources on Cellular and Molecular Biotechnology at CEB/IBB”, ref. FCOMP-01-0124-FEDER- 027462

    Protocol for Translabial 3D-Ultrasonography for diagnosing levator defects (TRUDIL): a multicentre cohort study for estimating the diagnostic accuracy of translabial 3D-ultrasonography of the pelvic floor as compared to MR imaging

    Get PDF
    Contains fulltext : 96237.pdf (publisher's version ) (Open Access)BACKGROUND: Pelvic organ prolapse (POP) is a condition affecting more than half of the women above age 40. The estimated lifetime risk of needing surgical management for POP is 11%. In patients undergoing POP surgery of the anterior vaginal wall, the re-operation rate is 30%. The recurrence risk is especially high in women with a levator ani defect. Such defect is present if there is a partially or completely detachment of the levator ani from the inferior ramus of the symphysis. Detecting levator ani defects is relevant for counseling, and probably also for treatment. Levator ani defects can be imaged with MRI and also with Translabial 3D ultrasonography of the pelvic floor. The primary aim of this study is to assess the diagnostic accuracy of translabial 3D ultrasonography for diagnosing levator defects in women with POP with Magnetic Resonance Imaging as the reference standard. Secondary goals of this study include quantification of the inter-observer agreement about levator ani defects and determining the association between levator defects and recurrent POP after anterior repair. In addition, the cost-effectiveness of adding translabial ultrasonography to the diagnostic work-up in patients with POP will be estimated in a decision analytic model. METHODS/DESIGN: A multicentre cohort study will be performed in nine Dutch hospitals. 140 consecutive women with a POPQ stage 2 or more anterior vaginal wall prolapse, who are indicated for anterior colporapphy will be included. Patients undergoing additional prolapse procedures will also be included. Prior to surgery, patients will undergo MR imaging and translabial 3D ultrasound examination of the pelvic floor. Patients will be asked to complete validated disease specific quality of life questionnaires before surgery and at six and twelve months after surgery. Pelvic examination will be performed at the same time points. Assuming a sensitivity and specificity of 90% of 3D ultrasound for diagnosing levator defects in a population of 120 women with POP, with a prior probability of levator ani defects of 40%, we will be able to estimate predictive values with good accuracy (i.e. confidence limits of at most 10% below or above the point estimates of positive and negative predictive values).Anticipating 3% unclassifiable diagnostic images because of technical reasons, and a further safety margin of 10% we plan to recruit 140 patients. TRIAL REGISTRATION: Nederlands trial register NTR2220

    Erratum to: 36th International Symposium on Intensive Care and Emergency Medicine

    Get PDF
    [This corrects the article DOI: 10.1186/s13054-016-1208-6.]

    Why do microorganisms produce rhamnolipids?

    Full text link
    corecore