30 research outputs found

    Ambulance response times - what is the standard?

    Get PDF
    Presentation delivered at the 33rd AvMA Annual Clinical Negligence Conference 23rd-24th March 2023, Bournemouth International Centre

    Can the British Heart Foundation PocketCPR Application Improve the Performance of Chest Compressions During Bystander Resuscitation: a Randomised Crossover Manikin Study

    Get PDF
    This study aims to determine whether the British Heart Foundation (BHF) PocketCPR application can improve the depth and rate of chest compression, and therefore be confidently recommended for bystander use. 118 candidates were recruited into a randomised crossover manikin trial. Each candidate performed CPR for two-minutes without instruction, or performed chest compressions using the PocketCPR application. Candidates then performed a further two minutes of CPR within the opposite arm. The number of chest compressions performed improved when PocketCPR was used compared to chest compressions when it was not (44.28% v40.57, P<0.001). The number of chest compressions performed to the required depth was higher in the PocketCPR group (90.86 v 66.26). The BHF PocketCPR application improved the percentage of chest compressions that were performed to the required depth. Despite this, more work is required in order to develop a feedback device that can improve bystander CPR without creating delay

    An exploration of UK Paramedics' experiences of Cardiopulmonary resuscitation induced consciousness

    Get PDF
    Introduction: Consciousness may occur during cardiopulmonary resuscitation despite the absence of a palpable pulse. This phenomenon, known as CPR-Induced Consciousness (CPR-IC) was first described over three decades ago and there has been an increase in case reports describing CPR-IC. However, there remains limited evidence in relation to the incidence of CPR-IC and to practitioners’ experiences of CPR-IC. Methods: A mixed methods, cross-sectional survey of paramedics who were registered with the Health and Care Professions Council (HCPC) and working in the United Kingdom (UK) at the time of the survey. Participants who had experienced CPR-IC were asked to provide details about the number of episodes, a description of how consciousness was manifested, and whether or not it interfered with resuscitation. Results: 293 eligible participants completed the study and 167 (57%) said that they had witnessed CPR-IC. Of those, over 56% reported that they had experienced it on at least two occasions. CPR-IC was deemed to interfere with resuscitation in nearly 50% of first experiences but this fell to around 31% by the third experience. The most common reasons for CPR-IC to interfere with resuscitation were; patient resisting clinical interventions, increased rhythm and pulse checks, distress, confusion and reluctance to perform CPR. Conclusions: The prevalence of CPR-IC in our study was similar to earlier studies; however, unlike the other studies, we did not define what constituted interfering CPR-IC. Our findings suggest that interference may be related as much to the exposure of the clinician to CPR-IC as to any specific characteristic of the phenomenon itself

    Accuracy of ECG Lead Placement by UK Paramedics

    Get PDF
    Background The use of the 12-lead ECG is common in UK paramedic practice but its value depends upon accurate placement of the ECG-electrodes. Several studies have shown widespread variation in the placement of chest electrodes by other health professionals but no studies have addressed the accuracy of paramedics. The main objective of this study was to ascertain the accuracy of the chest lead placements by registered paramedics. Methods Registered paramedics who attended the Emergency Services Show in Birmingham in September 2018 were invited to participate in this observational study. Participants were asked to place the chest electrodes on a male model in accordance with their current practice. Correct positioning was determined against the Society for Cardiological Science & Technology’s Clinical Guidelines for recording a standard 12-lead electrocardiogram (2017) with a tolerance of 19 mm being deemed acceptable based upon previous studies. Results 52 eligible participants completed the study. Measurement of electrode placement in the craniocaudal and mediolateral planes showed a high level of inaccuracy with 3/52 (5.8%) participants able to accurately place all chest leads. In leads V1 - V3, the majority of incorrect placements were related to vertical displacement with most participants able to identify the correct horizontal position. In V4, the tendency was to place the lead too low and to the left of the pre-determined position whilst V5 tended to be below the expected positioning but in the correct horizontal alignment. There was a less defined pattern of error in V6 although vertical displacement was more likely than horizontal displacement. Conclusions Our study identified a high level of variation in the placement of chest ECG electrodes which could alter the morphology of the ECG. From a patient safety perspective, we would advocate that paramedics leave the chest electrodes in situ to allow hospital staff to assess the accuracy of the placements

    Variability in Avian Eggshell Colour: A Comparative Study of Museum Eggshells

    Get PDF
    Background: The exceptional diversity of coloration found in avian eggshells has long fascinated biologists and inspired a broad range of adaptive hypotheses to explain its evolution. Three main impediments to understanding the variability of eggshell appearance are: (1) the reliable quantification of the variation in eggshell colours; (2) its perception by birds themselves, and (3) its relation to avian phylogeny. Here we use an extensive museum collection to address these problems directly, and to test how diversity in eggshell coloration is distributed among different phylogenetic levels of the class Aves. Methodology and Results: Spectrophotometric data on eggshell coloration were collected from a taxonomically representative sample of 251 bird species to determine the change in reflectance across different wavelengths and the taxonomic level where the variation resides. As many hypotheses for the evolution of eggshell coloration assume that egg colours provide a communication signal for an avian receiver, we also modelled reflectance spectra of shell coloration for the avian visual system. We found that a majority of species have eggs with similar background colour (long wavelengths) but that striking differences are just as likely to occur between congeners as between members of different families. The region of greatest variability in eggshell colour among closely related species coincided with the medium-wavelength sensitive region around 500 nm. Conclusions: The majority of bird species share similar background eggshell colours, while the greatest variability among species aligns with differences along a red-brown to blue axis that most likely corresponds with variation in the presence and concentration of two tetrapyrrole pigments responsible for eggshell coloration. Additionally, our results confirm previous findings of temporal changes in museum collections, and this will be of particular concern for studies testing intraspecific hypotheses relating temporal patterns to adaptation of eggshell colour. We suggest that future studies investigating the phylogenetic association between the composition and concentration of eggshell pigments, and between the evolutionary drivers and functional impacts of eggshell colour variability will be most rewarding.Phillip Cassey, Steven J. Portugal, Golo Maurer, John G. Ewen, Rebecca L. Boulton, Mark E. Hauber and Tim M. Blackbur

    Ten-year mortality, disease progression, and treatment-related side effects in men with localised prostate cancer from the ProtecT randomised controlled trial according to treatment received

    Get PDF
    Background The ProtecT trial reported intention-to-treat analysis of men with localised prostate cancer randomly allocated to active monitoring (AM), radical prostatectomy, and external beam radiotherapy. Objective To report outcomes according to treatment received in men in randomised and treatment choice cohorts. Design, setting, and participants This study focuses on secondary care. Men with clinically localised prostate cancer at one of nine UK centres were invited to participate in the treatment trial comparing AM, radical prostatectomy, and radiotherapy. Intervention Two cohorts included 1643 men who agreed to be randomised and 997 who declined randomisation and chose treatment. Outcome measurements and statistical analysis Analysis was carried out to assess mortality, metastasis and progression and health-related quality of life impacts on urinary, bowel, and sexual function using patient-reported outcome measures. Analysis was based on comparisons between groups defined by treatment received for both randomised and treatment choice cohorts in turn, with pooled estimates of intervention effect obtained using meta-analysis. Differences were estimated with adjustment for known prognostic factors using propensity scores. Results and limitations According to treatment received, more men receiving AM died of PCa (AM 1.85%, surgery 0.67%, radiotherapy 0.73%), whilst this difference remained consistent with chance in the randomised cohort (p = 0.08); stronger evidence was found in the exploratory analyses (randomised plus choice cohort) when AM was compared with the combined radical treatment group (p = 0.003). There was also strong evidence that metastasis (AM 5.6%, surgery 2.4%, radiotherapy 2.7%) and disease progression (AM 20.35%, surgery 5.87%, radiotherapy 6.62%) were more common in the AM group. Compared with AM, there were higher risks of sexual dysfunction (95% at 6 mo) and urinary incontinence (55% at 6 mo) after surgery, and of sexual dysfunction (88% at 6 mo) and bowel dysfunction (5% at 6 mo) after radiotherapy. The key limitations are the potential for bias when comparing groups defined by treatment received and changes in the protocol for AM during the lengthy follow-up required in trials of screen-detected PCa. Conclusions Analyses according to treatment received showed increased rates of disease-related events and lower rates of patient-reported harms in men managed by AM compared with men managed by radical treatment, and stronger evidence of greater PCa mortality in the AM group. Patient summary More than 95 out of every 100 men with low or intermediate risk localised prostate cancer do not die of prostate cancer within 10 yr, irrespective of whether treatment is by means of monitoring, surgery, or radiotherapy. Side effects on sexual and bladder function are better after active monitoring, but the risks of spreading of prostate cancer are more common