12 research outputs found

    Increased neutrophil-to-lymphocyte ratio predicts persistent coronary no-flow after wire insertion in patients with ST-elevation myocardial infarction undergoing primary percutaneous coronary intervention

    Get PDF
    OBJECTIVES: Acute ST-segment elevation myocardial infarction patients presenting persistent no-flow after wire insertion have a lower survival rate despite successful mechanical intervention. The neutrophil-to-lymphocyte ratio has been associated with increased mortality and worse clinical outcomes in ST-segment elevation myocardial infarction. We hypothesized that an elevated neutrophil-to-lymphocyte ratio would also be associated with a persistent Thrombolysis In Myocardial Infarction flow grade of 0 after wire insertion in patients undergoing primary percutaneous coronary intervention. METHODS: A total of 644 patients with ST-segment elevation myocardial infarction who underwent primary percutaneous coronary intervention within 12 hours of symptom onset were included in our study. Blood samples were drawn immediately upon hospital admission. The patients were divided into 3 groups according to their Thrombolysis In Myocardial Infarction flow grade: Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion, Thrombolysis In Myocardial Infarction flow grade 1-3 after wire insertion and Thrombolysis In Myocardial Infarction flow grade 1-3 at baseline. RESULTS: The neutrophil-to-lymphocyte ratio was significantly higher in the group with Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion compared with the group with Thrombolysis In Myocardial Infarction flow grade 1-3 after wire insertion and the group with Thrombolysis In Myocardial Infarction flow grade 1-3 at baseline. The group with Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion also had a significantly higher in-hospital mortality rate. Persistent coronary no-flow after wire insertion was independently associated with the neutrophil-to-lymphocyte ratio. CONCLUSIONS: An increased neutrophil-to-lymphocyte ratio on admission is significantly associated with persistent coronary no-flow after wire insertion in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention

    Ocular biometry and central corneal thickness in children: a hospital-based study

    No full text
    Objetivo: Investigar a distribuição do comprimento axial, profundidade da câmara anterior, espessura do cristalino, profundidade da câmara vítrea e espessura corneal central em crianças em diferentes faixas etárias. Métodos: Foram estudados 364 olhos de 182 crianças entre 1 e 12 anos de idade. O comprimento axial, a profundidade da câmara anterior , a espessura do cristalino e a profundidade da câmara vítrea foram medidos por biometria ultrassônica. A espessura corneal central foi medida por paquimetria ultrassônica em todas as crianças. Resultados: A idade média foi de 6,54 ± 3,42 anos. O comprimento axial foi 20,95 mm no grupo de 1-2 anos de idade e 22,95 mm no grupo de 11-12 anos de idade. A espessura corneal central foi 556 µm no grupo de 1-2 anos de idade e 555 µm no grupo de 11-12 anos de idade. A profundidade da câmara anterior média e profundidade da câmara vítrea aumentou com a idade (3,06 mm a 3,44 mm de profundidade da câmara anterior, 13,75 mm a 15,99 mm de profundidade da câmara vítrea) e da espessura do cristalino diminuiu com o aumento da idade (3,67 mm a 3,51 mm). Conclusões: Em nosso estudo, os valores do comprimento axial aumentou com a idade e atingiu os níveis adultos aos 9-10 anos de idade. A espessura do cristalino diminuiu gradualmente até os 12 anos de idade. As medições de espessura corneal central não seguiu um algoritmo linear

    Change in tear film characteristics in visual display terminal users

    No full text
    23rd Annual Meeting of the American-Glaucoma-Society -- FEB 28-MAR 03, 2013 -- Amer Glaucoma Soc, San Francisco, CAWOS: 000357614000004PubMed: 25363850Purpose: To evaluate changes in symptoms and tear film characteristics in young computer users. Methods: Fifty-one computer users and 26 controls were evaluated at the beginning and the end of the working day. Subjects with ocular or systemic disease, history of ocular surgery, use of contact lenses or glasses with antireflective surfaces, and use of topical or systemic medications were excluded from the study. Computer use duration, Ocular Surface Disease Index (OSDI) questionnaire, tear osmolarity, Schirmer test, tear break-up time (TBUT), and ocular surface vital dye staining were performed prevocationally and postvocationally. Results: The mean age was 31.2 +/- 6.3 years in computer users and 33.7 +/- 5.8 in controls. The mean reported computer use was 6.9 +/- 2.7 hours/day in computer users and 0.4 +/- 0.5 hours/day in controls. The mean prevocational and postvocational values in computer users for OSDI, osmolarity, TBUT, and Schirmer test were 23.2 +/- 16.6 and 27.0 +/- 17.6, 306.6 +/- 14.9 and 311.0 +/- 12.5 mOsm/L, 13.9 +/- 4.0 and 13.2 +/- 3.8 seconds, 22.7 +/- 11.8 and 20.6 +/- 12.5 mm, respectively. The vocational change was significant for all parameters in the computer user group but not in the control group. The osmolarity-based dry eye diagnosis was 27.4% in the computer users while it was 15.4% in the control group. Oxford score was only grade 1 in 5.9% of visual display terminal users and did not change at the end of the day. Conclusions: Both symptoms and signs of dry eye increased significantly with computer use. Approximately 1 of every 3-4 computer users was found to have dry eye with higher tear osmolarity values

    Increased neutrophil-to-lymphocyte ratio predicts persistent coronary no-flow after wire insertion in patients with ST-elevation myocardial infarction undergoing primary percutaneous coronary intervention

    No full text
    OBJECTIVES: Acute ST-segment elevation myocardial infarction patients presenting persistent no-flow after wire insertion have a lower survival rate despite successful mechanical intervention. The neutrophil-to-lymphocyte ratio has been associated with increased mortality and worse clinical outcomes in ST-segment elevation myocardial infarction. We hypothesized that an elevated neutrophil-to-lymphocyte ratio would also be associated with a persistent Thrombolysis In Myocardial Infarction flow grade of 0 after wire insertion in patients undergoing primary percutaneous coronary intervention. METHODS: A total of 644 patients with ST-segment elevation myocardial infarction who underwent primary percutaneous coronary intervention within 12 hours of symptom onset were included in our study. Blood samples were drawn immediately upon hospital admission. The patients were divided into 3 groups according to their Thrombolysis In Myocardial Infarction flow grade: Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion, Thrombolysis In Myocardial Infarction flow grade 1-3 after wire insertion and Thrombolysis In Myocardial Infarction flow grade 1-3 at baseline. RESULTS: The neutrophil-to-lymphocyte ratio was significantly higher in the group with Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion compared with the group with Thrombolysis In Myocardial Infarction flow grade 1-3 after wire insertion and the group with Thrombolysis In Myocardial Infarction flow grade 1-3 at baseline. The group with Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion also had a significantly higher in-hospital mortality rate. Persistent coronary no-flow after wire insertion was independently associated with the neutrophil-to-lymphocyte ratio. CONCLUSIONS: An increased neutrophil-to-lymphocyte ratio on admission is significantly associated with persistent coronary no-flow after wire insertion in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention

    The protective effect of selenium in cisplatin-related retinotoxicity

    No full text
    Purpose: The aim of this study is to evaluate the retinal toxicity of cisplatin and neuroprotective effect of selenium in cisplatin-related retinal toxicity

    Selenium Protects Retinal Cells from Cisplatin-Induced Alterations in Carbohydrate Residues

    No full text
    Background: Investigate alterations in the expression and localization of carbohydrate units in rat retinal cells exposed to cisplatin toxicity

    The prevalence of 4G/5G polymorphism of plasminogen activator inhibitor-1 ( PAI

    No full text
    Context: Central serous chorioretinopathy (CSCR) is a poorly understood disease and the choroidal circulation abnormality induced by the plasminogen activator inhibitor type 1 (PAI-1) seems to be associated with the pathogenesis. There are many reports indicating that 4G/5G polymorphism of the PAI-1 gene is a risk factor for several diseases related to the elevated serum levels of PAI-1. Objective: To evaluate the 4G/5G polymorphism of the PAI-1 gene and its association with serum levels of PAI-1 in acute CSCR patients. Materials and methods: Sixty CSCR patients and 50 healthy control patients were included. The PAI-1 4G/5G was genotyped using the polymerase chain reaction-restriction technique. Serum PAI-1 level was measured using enzyme-linked immunosorbent assay. Demographic data consisting of age, sex, body mass index (BMI) as well as genotype disturbances and serum PAI-1 levels were compared between the groups. Statistical significance for differences in the serum PAI-1 levels of each group with different genotypes was also analyzed. Results: The CSCR group consisted of 40 male (66.7%) and 20 female (33.3%) patients with a mean age of 46.7 +/- 8.39 years. The control group consisted of 32 male (64%) and 18 female (36%) healthy subjects with a mean age of 45.8 +/- 8.39 years. There was no statistically significant difference between the groups in terms of age, sex and BMI. In the CSCR group the genotype frequencies were 4G/4G: 30% (n = 18), 4G/5G: 50% (n = 30), 5G/5G: 20% (n = 12) and in the control group genotype frequencies were 34% (n = 17), 42% (n = 21) and 24% (n = 12), respectively. There was no statistically significant difference in the distribution of genotypes among the groups (chi-squared, p = 0.70). The CSCR group had a significantly higher serum PAI-1 concentration than the control group (p = 0.001). In both groups the mean plasma PAI-1 concentration did not vary significantly among the different genotypes (p > 0.05). Discussion and conclusion: Although our results demonstrated that the patients with acute CSCR have higher serum PAI-1 concentrations than the controls, no significant difference was found in the genotype disturbances of the PAI-1 gene between the groups. The current study indicates that 4G/5G polymorphism in the promoter of the PAI-1 gene cannot be considered a risk factor for the elevated serum PAI-1 levels and consequent development of CSCR

    CEPC Conceptual Design Report: Volume 2 - Physics & Detector

    No full text
    The Circular Electron Positron Collider (CEPC) is a large international scientific facility proposed by the Chinese particle physics community to explore the Higgs boson and provide critical tests of the underlying fundamental physics principles of the Standard Model that might reveal new physics. The CEPC, to be hosted in China in a circular underground tunnel of approximately 100 km in circumference, is designed to operate as a Higgs factory producing electron-positron collisions with a center-of-mass energy of 240 GeV. The collider will also operate at around 91.2 GeV, as a Z factory, and at the WW production threshold (around 160 GeV). The CEPC will produce close to one trillion Z bosons, 100 million W bosons and over one million Higgs bosons. The vast amount of bottom quarks, charm quarks and tau-leptons produced in the decays of the Z bosons also makes the CEPC an effective B-factory and tau-charm factory. The CEPC will have two interaction points where two large detectors will be located. This document is the second volume of the CEPC Conceptual Design Report (CDR). It presents the physics case for the CEPC, describes conceptual designs of possible detectors and their technological options, highlights the expected detector and physics performance, and discusses future plans for detector R&D and physics investigations. The final CEPC detectors will be proposed and built by international collaborations but they are likely to be composed of the detector technologies included in the conceptual designs described in this document. A separate volume, Volume I, recently released, describes the design of the CEPC accelerator complex, its associated civil engineering, and strategic alternative scenarios
    corecore