114 research outputs found

    Sequential bipolar radiofrequency lumbar sympathectomy in Raynaud's disease -A case report-

    Get PDF
    A 39-year-old female was suffering from cold-induced Raynaud's attacks in both hands and feet, with symptoms being most severe in her left foot. The patient did not respond to medical treatments and was referred to our department of pain medicine. We performed sequential bipolar radiofrequency lumbar sympathectomy to the patient, which offered a long duration of symptom relief. Sequential bipolar radiofrequency lesions could create continuous strip lesion, and thus, could achieve better results, while the potential risk of liquid neurolytic agents could be avoided

    Symptomatic epidural gas cyst treated with epidural block and percutaneous needle aspiration -A case report-

    Get PDF
    A 68-year-old woman suffered from lower back and radiating pain on her right buttock and posterior calf. Axial magnetic resonance imaging showed a 7 × 7 mm nodular lesion (T1 and, T2 low signal intensity) at the epidural space between the L5-S1 level and computed tomography revealed it was an epidural gas cyst. The authors performed an epidural block and percutaneous needle aspiration of the epidural gas cyst. The patient showed almost complete resolution of symptoms one year later. The authors suggest that an epidural nerve block with needle aspiration of a gas cyst could be an alternative treatment option for patients with a symptomatic epidural gas cyst before surgery

    Percutaneous aspiration of lumbar zygapophyseal joint synovial cyst under fluoroscopic guidance -A case report-

    Get PDF
    A 51-year-old man with a 1-month history of lower back pain and radiating pain visited to our pain clinic. A magnetic resonance imaging (MRI) scan demonstrated a cyst like mass at the level of the L4-5 interspace and compression of the thecal sac and the nerve root on the right side. We performed percutaneous needle aspiration of the lumbar zygapophyseal joint synovial cyst under fluoroscopic guidance. The patient felt an immediate relief of symptoms after the aspiration, and had no signs or symptoms of recurrence at the follow-up 6 months later. No demonstrable lesion was found in the 6 months follow-up MRI

    Comparison between Occlusal Errors of Single Posterior Crowns Adjusted Using Patient Specific Motion or Conventional Methods

    Get PDF
    Recently, digital technology has been used in dentistry to enhance accuracy and to reduce operative time. Due to advances in digital technology, the integration of individual mandibular motion into the mapping of the occlusal surface is being attempted. The Patient Specific Motion (PSM) is one such method. However, it is not clear whether the occlusal design that is adjusted using PSM could clinically show reduced occlusal error compared to conventional methods based on static occlusion. In this clinical comparative study including fifteen patients with a single posterior zirconia crown treatment, the occlusal surface after a clinical adjustment was compared to no adjustment (NA; design based on static occlusion), PSM (adjusted using PSM), and adjustment using a semi-adjustable articulator (SA) for the assessment of occlusal error. The root mean square (RMS; mu m), average deviation value (+/- AVG; mu m), and proportion inside the tolerance (in Tol; %) were calculated using the entire, subdivided occlusal surface and the out of tolerance area. Using a one-way ANOVA, the RMS and +AVG from the out of tolerance area showed a statistical difference between PSM (202.3 +/- 39.8 for RMS, 173.1 +/- 31.3 for +AVG) and NA (257.0 +/- 73.9 for RMS, 210.9 +/- 48.6 for +AVG). For the entire and subdivided occlusal surfaces, there were no significant differences. In the color-coded map analysis, PSM demonstrated a reduced occlusal error compared to NA. In conclusion, adjustment occlusal design using PSM is a simple and effective method for reducing occlusal errors that are difficult to identify in a current computer-aided design (CAD) workflow with static occlusion.11Nsciescopu

    Partial-Thickness Rotator Cuff Tears

    Get PDF
    Although the incidence of partial-thickness rotator cuff tears (PTRCTs) was reported to be from 13% to 32% in cadaveric studies, the actual incidence is not yet known. The causes of PTRCTs can be explained by either extrinsic or intrinsic theories. Studies suggest that intrinsic degeneration within the rotator cuff is the principal factor in the pathogenesis of rotator cuff tears. Extrinsic causes include subacromial impingement, acute traumatic events, and repetitive microtrauma. However, acromially initiated rotator cuff pathology does not occur and extrinsic impingement does not cause pathology on the articular side of the tendon. An arthroscopic classification system has been developed based on the location and depth of the tear. These include the articular, bursal, and intratendinous areas. Both ultrasound and magnetic resonance image are reported with a high accuracy of 87%. Conservative treatment, such as subacromial or intra-articular injections and suprascapular nerve block with or without block of the articular branches of the circumflex nerve, should be considered prior to operative treatment for PTRCTs

    Erratum to: Population attributable risks of modifiable reproductive factors for breast and ovarian cancers in Korea

    Get PDF
    This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made

    Population attributable risks of modifiable reproductive factors for breast and ovarian cancers in Korea

    Get PDF
    This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.Abstract Background Breast and ovarian cancers are predominant female cancers with increasing prevalence. The purpose of this study was to estimate the population attributable risks (PARs) of breast and ovarian cancer occurrence based on the relative risks (RRs) of modifiable reproductive factors and population-specific exposure prevalence. Methods The PAR was calculated by using the 1990 standardized prevalence rates, the 2010 national cancer incidence with a 20 year lag period, the meta-analyzed RRs from studies conducted in the Korean population for breast cancer, and the meta-analyzed RRs from a Korean epithelial ovarian cancer study and a prior meta-analysis, and ovarian cancer cohort results up to 2012. For oral contraceptive and hormone replacement therapy use, we did not consider lag period. Results The summary PARs for modifiable reproductive factors were 16.7 % (95 % CI 15.8–17.6) for breast cancer (2404 cases) and 81.9 % (95 % CI 55.0–100.0) for ovarian cancer (1579 cases). The modifiable reproductive factors included pregnancy/age at first birth (8.0 %), total period of breastfeeding (3.1 %), oral contraceptive use (5.3 %), and hormone replacement therapy use (0.3 %) for breast cancer and included breastfeeding experience (2.9 %), pregnancy (1.2 %), tubal ligation (24.5 %), and oral contraceptive use (53.3 %) for ovarian cancer. Conclusions Despite inherent uncertainties in the risk factors for breast and ovarian cancers, we suggest that appropriate long-term control of modifiable reproductive factors could reduce breast and ovarian cancer incidences and their related burdens by 16.7 % and 81.9 %, respectively

    Atrasentan and renal events in patients with type 2 diabetes and chronic kidney disease (SONAR): a double-blind, randomised, placebo-controlled trial

    Get PDF
    Background: Short-term treatment for people with type 2 diabetes using a low dose of the selective endothelin A receptor antagonist atrasentan reduces albuminuria without causing significant sodium retention. We report the long-term effects of treatment with atrasentan on major renal outcomes. Methods: We did this double-blind, randomised, placebo-controlled trial at 689 sites in 41 countries. We enrolled adults aged 18–85 years with type 2 diabetes, estimated glomerular filtration rate (eGFR)25–75 mL/min per 1·73 m 2 of body surface area, and a urine albumin-to-creatinine ratio (UACR)of 300–5000 mg/g who had received maximum labelled or tolerated renin–angiotensin system inhibition for at least 4 weeks. Participants were given atrasentan 0·75 mg orally daily during an enrichment period before random group assignment. Those with a UACR decrease of at least 30% with no substantial fluid retention during the enrichment period (responders)were included in the double-blind treatment period. Responders were randomly assigned to receive either atrasentan 0·75 mg orally daily or placebo. All patients and investigators were masked to treatment assignment. The primary endpoint was a composite of doubling of serum creatinine (sustained for ≥30 days)or end-stage kidney disease (eGFR <15 mL/min per 1·73 m 2 sustained for ≥90 days, chronic dialysis for ≥90 days, kidney transplantation, or death from kidney failure)in the intention-to-treat population of all responders. Safety was assessed in all patients who received at least one dose of their assigned study treatment. The study is registered with ClinicalTrials.gov, number NCT01858532. Findings: Between May 17, 2013, and July 13, 2017, 11 087 patients were screened; 5117 entered the enrichment period, and 4711 completed the enrichment period. Of these, 2648 patients were responders and were randomly assigned to the atrasentan group (n=1325)or placebo group (n=1323). Median follow-up was 2·2 years (IQR 1·4–2·9). 79 (6·0%)of 1325 patients in the atrasentan group and 105 (7·9%)of 1323 in the placebo group had a primary composite renal endpoint event (hazard ratio [HR]0·65 [95% CI 0·49–0·88]; p=0·0047). Fluid retention and anaemia adverse events, which have been previously attributed to endothelin receptor antagonists, were more frequent in the atrasentan group than in the placebo group. Hospital admission for heart failure occurred in 47 (3·5%)of 1325 patients in the atrasentan group and 34 (2·6%)of 1323 patients in the placebo group (HR 1·33 [95% CI 0·85–2·07]; p=0·208). 58 (4·4%)patients in the atrasentan group and 52 (3·9%)in the placebo group died (HR 1·09 [95% CI 0·75–1·59]; p=0·65). Interpretation: Atrasentan reduced the risk of renal events in patients with diabetes and chronic kidney disease who were selected to optimise efficacy and safety. These data support a potential role for selective endothelin receptor antagonists in protecting renal function in patients with type 2 diabetes at high risk of developing end-stage kidney disease. Funding: AbbVie

    New Era of Air Quality Monitoring from Space: Geostationary Environment Monitoring Spectrometer (GEMS)

    Get PDF
    GEMS will monitor air quality over Asia at unprecedented spatial and temporal resolution from GEO for the first time, providing column measurements of aerosol, ozone and their precursors (nitrogen dioxide, sulfur dioxide and formaldehyde). Geostationary Environment Monitoring Spectrometer (GEMS) is scheduled for launch in late 2019 - early 2020 to monitor Air Quality (AQ) at an unprecedented spatial and temporal resolution from a Geostationary Earth Orbit (GEO) for the first time. With the development of UV-visible spectrometers at sub-nm spectral resolution and sophisticated retrieval algorithms, estimates of the column amounts of atmospheric pollutants (O3, NO2, SO2, HCHO, CHOCHO and aerosols) can be obtained. To date, all the UV-visible satellite missions monitoring air quality have been in Low Earth orbit (LEO), allowing one to two observations per day. With UV-visible instruments on GEO platforms, the diurnal variations of these pollutants can now be determined. Details of the GEMS mission are presented, including instrumentation, scientific algorithms, predicted performance, and applications for air quality forecasts through data assimilation. GEMS will be onboard the GEO-KOMPSAT-2 satellite series, which also hosts the Advanced Meteorological Imager (AMI) and Geostationary Ocean Color Imager (GOCI)-2. These three instruments will provide synergistic science products to better understand air quality, meteorology, the long-range transport of air pollutants, emission source distributions, and chemical processes. Faster sampling rates at higher spatial resolution will increase the probability of finding cloud-free pixels, leading to more observations of aerosols and trace gases than is possible from LEO. GEMS will be joined by NASA&apos;s TEMPO and ESA&apos;s Sentinel-4 to form a GEO AQ satellite constellation in early 2020s, coordinated by the Committee on Earth Observation Satellites (CEOS)
    corecore