484 research outputs found

    On the effects of geometry control on the performance of overtopping wave energy converters

    Get PDF
    Overtopping wave energy converters (OWECs) are designed to extract energy from ocean waves based on wave overtopping into a reservoir, which is emptied into the ocean through a set of low-head turbines, and typically feature a low crest freeboard and a smooth impermeable steep slope. In the process of optimizing the performance of OWECs, the question arises whether adapting the slope geometry to the variable wave characteristics at the deployment site (i.e., geometry control) can increase the overall hydraulic efficiency and overall hydraulic power compared to a fixed slope geometry. The effect of five different geometry control scenarios on the overall hydraulic efficiency and overall hydraulic power of OWECs has been simulated for three possible deployment sites using empirical prediction formulae. The results show that the effect of an adaptive slope angle is relatively small. On the other hand, adapting the crest freeboard of the OWECs to the wave characteristics increases the overall hydraulic efficiency and power. Based on the simulations, gains in overall hydraulic power of at least 30% are achievable when applying an adaptive crest freeboard compared to a fixed crest freeboard

    Nuclear structure and reaction studies at SPIRAL

    Get PDF
    The SPIRAL facility at GANIL, operational since 2001, is described briefly. The diverse physics program using the re-accelerated (1.2 to 25 MeV/u) beams ranging from He to Kr and the instrumentation specially developed for their exploitation are presented. Results of these studies, using both direct and compound processes, addressing various questions related to the existence of exotic states of nuclear matter, evolution of new "magic numbers", tunnelling of exotic nuclei, neutron correlations, exotic pathways in astrophysical sites and characterization of the continuum are discussed. The future prospects for the facility and the path towards SPIRAL2, a next generation ISOL facility, are also briefly presented.Comment: 48 pages, 27 figures. Accepted for publication in Journal of Physics

    Standard Model tests with trapped radioactive atoms

    Full text link
    We review the use of laser cooling and trapping for Standard Model tests, focusing on trapping of radioactive isotopes. Experiments with neutral atoms trapped with modern laser cooling techniques are testing several basic predictions of electroweak unification. For nuclear β\beta decay, demonstrated trap techniques include neutrino momentum measurements from beta-recoil coincidences, along with methods to produce highly polarized samples. These techniques have set the best general constraints on non-Standard Model scalar interactions in the first generation of particles. They also have the promise to test whether parity symmetry is maximally violated, to search for tensor interactions, and to search for new sources of time reversal violation. There are also possibilites for exotic particle searches. Measurements of the strength of the weak neutral current can be assisted by precision atomic experiments using traps of small numbers of radioactive atoms, and sensitivity to possible time-reversal violating electric dipole moments can be improved.Comment: 45 pages, 17 figures, v3 includes clarifying referee comments, especially in beta decay section, and updated figure

    Total ankle prostheses in rheumatoid arthropathy: Outcome in 52 patients followed for 1–9 years

    Get PDF
    Background and purpose The first generations of total ankle replacements (TARs) showed a high rate of early failure. In the last decades, much progress has been made in the development of TARs, with the newer generation showing better results. We evaluated TARs implanted with rheumatoid arthritis (RA) or juvenile inflammatory arthritis (JIA) as indication

    Erytrocyte membrane anionic charge in type 2 diabetic patients with retinopathy

    Get PDF
    BACKGROUND: The Steno hypothesis states that changes in basement membrane anionic charge leads to diabetic microvascular complications. In diabetic nephropathy, loss of basement membrane glycosaminoglycans and the association between glomerular basement membrane heparan sulphate and proteinuria has been documented. A correlation between erythrocyte surface and the glomerular capillary wall charges has also been observed. The aim of this study is to evaluate the relationship between retinopathy and erythrocyte anionic charge and urinary glycosaminoglycan excretion in type 2 diabetic patients. METHODS: 49 subjects (58 ± 7 yrs, M/F 27/22) with type 2 diabetes with proliferative retinopathy (n = 13), nonproliferative retinopathy (n = 13) and without retinopathy (n = 23) were included in the study. 38 healthy subjects were selected as control group (57 ± 5 yrs, M/F 19/19). Erythrocyte anionic charge (EAC) was determined by the binding of the cationic dye, alcian blue. Urinary glycosaminoglycan and microalbumin excretion were measured. RESULTS: EAC was significantly decreased in diabetic patients with retinopathy (255 ± 30 ng alcian blue/10(6 )RBC, 312 ± 30 ng alcian blue/10(6 )RBC for diabetic and control groups respectively, p < 0.001). We did not observe an association between urinary GAG and microalbumin excretion and diabetic retinopathy. EAC is found to be negatively corralated with microalbuminuria in all groups. CONCLUSIONS: We conclude that type 2 diabetic patients with low erythrocyte anionic charge are associated with diabetic retinopathy. Reduction of negative charge of basement membranes may indicate general changes in microvasculature rather than retinopathy. More prospective and large studies needs to clarify the role of glycosaminoglycans on progression of retinopathy in type 2 diabetic patients

    Clinical quantitative cardiac imaging for the assessment of myocardial ischaemia

    Get PDF
    Cardiac imaging has a pivotal role in the prevention, diagnosis and treatment of ischaemic heart disease. SPECT is most commonly used for clinical myocardial perfusion imaging, whereas PET is the clinical reference standard for the quantification of myocardial perfusion. MRI does not involve exposure to ionizing radiation, similar to echocardiography, which can be performed at the bedside. CT perfusion imaging is not frequently used but CT offers coronary angiography data, and invasive catheter-based methods can measure coronary flow and pressure. Technical improvements to the quantification of pathophysiological parameters of myocardial ischaemia can be achieved. Clinical consensus recommendations on the appropriateness of each technique were derived following a European quantitative cardiac imaging meeting and using a real-time Delphi process. SPECT using new detectors allows the quantification of myocardial blood flow and is now also suited to patients with a high BMI. PET is well suited to patients with multivessel disease to confirm or exclude balanced ischaemia. MRI allows the evaluation of patients with complex disease who would benefit from imaging of function and fibrosis in addition to perfusion. Echocardiography remains the preferred technique for assessing ischaemia in bedside situations, whereas CT has the greatest value for combined quantification of stenosis and characterization of atherosclerosis in relation to myocardial ischaemia. In patients with a high probability of needing invasive treatment, invasive coronary flow and pressure measurement is well suited to guide treatment decisions. In this Consensus Statement, we summarize the strengths and weaknesses as well as the future technological potential of each imaging modality

    Diagnosis of obstructive coronary artery disease using computed tomography angiography in patients with stable chest pain depending on clinical probability and in clinically important subgroups: meta-analysis of individual patient data

    Get PDF
    OBJECTIVE: To determine whether coronary computed tomography angiography (CTA) should be performed in patients with any clinical probability of coronary artery disease (CAD), and whether the diagnostic performance differs between subgroups of patients. DESIGN: Prospectively designed meta-analysis of individual patient data from prospective diagnostic accuracy studies. DATA SOURCES: Medline, Embase, and Web of Science for published studies. Unpublished studies were identified via direct contact with participating investigators. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Prospective diagnostic accuracy studies that compared coronary CTA with coronary angiography as the reference standard, using at least a 50% diameter reduction as a cutoff value for obstructive CAD. All patients needed to have a clinical indication for coronary angiography due to suspected CAD, and both tests had to be performed in all patients. Results had to be provided using 2Ă—2 or 3Ă—2 cross tabulations for the comparison of CTA with coronary angiography. Primary outcomes were the positive and negative predictive values of CTA as a function of clinical pretest probability of obstructive CAD, analysed by a generalised linear mixed model; calculations were performed including and excluding non-diagnostic CTA results. The no-treat/treat threshold model was used to determine the range of appropriate pretest probabilities for CTA. The threshold model was based on obtained post-test probabilities of less than 15% in case of negative CTA and above 50% in case of positive CTA. Sex, angina pectoris type, age, and number of computed tomography detector rows were used as clinical variables to analyse the diagnostic performance in relevant subgroups. RESULTS: Individual patient data from 5332 patients from 65 prospective diagnostic accuracy studies were retrieved. For a pretest probability range of 7-67%, the treat threshold of more than 50% and the no-treat threshold of less than 15% post-test probability were obtained using CTA. At a pretest probability of 7%, the positive predictive value of CTA was 50.9% (95% confidence interval 43.3% to 57.7%) and the negative predictive value of CTA was 97.8% (96.4% to 98.7%); corresponding values at a pretest probability of 67% were 82.7% (78.3% to 86.2%) and 85.0% (80.2% to 88.9%), respectively. The overall sensitivity of CTA was 95.2% (92.6% to 96.9%) and the specificity was 79.2% (74.9% to 82.9%). CTA using more than 64 detector rows was associated with a higher empirical sensitivity than CTA using up to 64 rows (93.4% v 86.5%, P=0.002) and specificity (84.4% v 72.6%, P<0.001). The area under the receiver-operating-characteristic curve for CTA was 0.897 (0.889 to 0.906), and the diagnostic performance of CTA was slightly lower in women than in with men (area under the curve 0.874 (0.858 to 0.890) v 0.907 (0.897 to 0.916), P<0.001). The diagnostic performance of CTA was slightly lower in patients older than 75 (0.864 (0.834 to 0.894), P=0.018 v all other age groups) and was not significantly influenced by angina pectoris type (typical angina 0.895 (0.873 to 0.917), atypical angina 0.898 (0.884 to 0.913), non-anginal chest pain 0.884 (0.870 to 0.899), other chest discomfort 0.915 (0.897 to 0.934)). CONCLUSIONS: In a no-treat/treat threshold model, the diagnosis of obstructive CAD using coronary CTA in patients with stable chest pain was most accurate when the clinical pretest probability was between 7% and 67%. Performance of CTA was not influenced by the angina pectoris type and was slightly higher in men and lower in older patients. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42012002780

    Early pyloric stenosis: a case control study

    Get PDF
    Pyloric stenosis (PS) is rare in the first 2 weeks of life, often leading to delays in diagnosis and treatment. We conducted a case control study to delineate the characteristics of patients with early PS (EPS). In addition, we tested the hypothesis that patients with EPS present with a smaller pylorus than older patients. A database of all patients presenting with PS to a children’s hospital over a 5-year period (2002–2006) was obtained. Each patient admitted during the first 2 weeks of life (subject) was matched to a patient admitted after 4 weeks of age (control), with the same gender, electrolyte status, and treating surgeon. A single pediatric radiologist, blinded to patient age, reviewed all available ultrasounds retrospectively. Demographic, clinical, diagnostic, therapeutic, and outcome data were compared. During the study period, 278 pyloromyotomies were performed for PS. Sixteen patients (5.8%) presented with EPS between 2 and 14 days of life. EPS patients had a higher prevalence of positive family history (31 vs. 0%, P = 0.043), and breast milk feeding (75 vs. 31%, P = 0.045). Sonographic measurements showed a pylorus that was of significantly less length (17.1 ± 0.6 vs. 20.5 ± 0.9 mm, P = 0.006) and muscle thickness (3.5 ± 0.2 vs. 4.9 ± 0.2 mm, P &lt; 0.001) in patients with EPS. Hospital stay was significantly longer for EPS patients (4.3 ± 0.9 vs. 2.0 ± 0.1 days, P = 0.19) Babies presenting with EPS are more likely to be breast fed and to have a positive family history. EPS is associated with a longer hospital stay. Use of sonographic diagnostic measurements specific to this age group may prevent delays in diagnosis and treatment, and improve outcomes
    • …
    corecore