161 research outputs found
Three-dimensional track reconstruction for directional Dark Matter detection
Directional detection of Dark Matter is a promising search strategy. However,
to perform such detection, a given set of parameters has to be retrieved from
the recoiling tracks : direction, sense and position in the detector volume. In
order to optimize the track reconstruction and to fully exploit the data of
forthcoming directional detectors, we present a likelihood method dedicated to
3D track reconstruction. This new analysis method is applied to the MIMAC
detector. It requires a full simulation of track measurements in order to
compare real tracks to simulated ones. We conclude that a good spatial
resolution can be achieved, i.e. sub-mm in the anode plane and cm along the
drift axis. This opens the possibility to perform a fiducialization of
directional detectors. The angular resolution is shown to range between
20 to 80, depending on the recoil energy, which is however
enough to achieve a high significance discovery of Dark Matter. On the
contrary, we show that sense recognition capability of directional detectors
depends strongly on the recoil energy and the drift distance, with small
efficiency values (50%-70%). We suggest not to consider this information either
for exclusion or discovery of Dark Matter for recoils below 100 keV and then to
focus on axial directional data.Comment: 27 pages, 20 figure
Off-shell effects on particle production
We investigate the observable effects of off-shell propagation of nucleons in
heavy-ion collisions at SIS energies. Within a semi-classical BUU transport
model we find a strong enhancement of subthreshold particle production when
off-shell nucleons are propagated.Comment: 11 pages, 3 figure
Non-Linear Mean Field Dynamics in the Nuclear Spinodal Zone
We demonstrate, by numerical simulations, that the dynamics of nuclear matter
mean field inside the spinodal region is chaotic. Spontaneous symmetry-breaking
- no explicit fluctuating term is considered - occurs leading to wild
unpredictable density fluctuations. A proper recipe to calculate an average
Lyapunov exponent in this multidimensional phase space is introduced. The
latter is calculated for different values of the density in order to
characterize in a quantitative way the chaotic and regular regions. It is
argued that the mean field chaoticity can be the main mechanism of the nuclear
multifragmentation occurring in the intermediate energy reactions.Comment: 11 pages (3 figures not included but available upon request). In
RevTex (version 3.0). Catania University preprint no.93/2
Results for the response function determination of the Compact Neutron Spectrometer
The Compact Neutron Spectrometer (CNS) is a Joint European Torus (JET)
Enhancement Project, designed for fusion diagnostics in different plasma
scenarios. The CNS is based on a liquid scintillator (BC501A) which allows good
discrimination between neutron and gamma radiation. Neutron spectrometry with a
BC501A spectrometer requires the use of a reliable, fully characterized
detector. The determination of the response matrix was carried out at the Ion
Accelerator Facility (PIAF) of the Physikalisch-Technische Bundesanstalt (PTB).
This facility provides several monoenergetic beams (2.5, 8, 10, 12 and 14 MeV)
and a 'white field'(Emax ~17 MeV), which allows for a full characterization of
the spectrometer in the region of interest (from ~1.5 MeV to ~17 MeV. The
energy of the incoming neutrons was determined by the time of flight method
(TOF), with time resolution in the order of 1 ns. To check the response matrix,
the measured pulse height spectra were unfolded with the code MAXED and the
resulting energy distributions were compared with those obtained from TOF. The
CNS project required modification of the PTB BC501A spectrometer design, to
replace an analog data acquisition system (NIM modules) with a digital system
developed by the 'Ente per le Nuove tecnologie, l'Energia e l'Ambiente' (ENEA).
Results for the new digital system were evaluated using new software developed
specifically for this project.Comment: Proceedings of FNDA 201
Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator
Various neutron diagnostic tools are used in fusion reactors to evaluate
different aspects of plasma performance, such as fusion power, power density,
ion temperature, fast ion energy, and their spatial distributions. The stilbene
scintillator has been proposed for use as a neutron diagnostic system to
measure the characteristics of neutrons from the Korea Superconducting Tokamak
Advanced Research (KSTAR) fusion reactor. Specially designed electronics are
necessary to measure fast neutron spectra with high radiation from a gamma-ray
background. The signals from neutrons and gamma-rays are discriminated by the
digital charge pulse shape discrimination (PSD) method, which uses total to
partial charge ratio analysis. The signals are digitized by a flash
analog-to-digital convertor (FADC). To evaluate the performance of the
fabricated stilbene neutron diagnostic system, the efficiency of 10 mm
soft-iron magnetic shielding and the detection efficiency of fast neutrons were
tested experimentally using a 252Cf neutron source. In the results, the
designed and fabricated stilbene neutron diagnostic system performed well in
discriminating neutrons from gamma-rays under the high magnetic field
conditions during KSTAR operation. Fast neutrons of 2.45 MeV were effectively
measured and evaluated during the 2011 KSTAR campaign.Comment: 15 pages, 14 figures, conferenc
Application of coded apertures in tomographic head scanning
A circular ring tomograph, designated SPRINT, is under development for single photon emission tomography of the human head. Most data to date have been gathered using a single rotating slit inside the detector ring to define ray directions. As an alternative method, we have also investigated the use of multiplexed slit patterns consisting of a pseudorandom binary code. From theoretical considerations, one would expect that the substitution of the code for the single slit would have potential advantages in reducing statistical noise in tomographic images of small objects. It has been our experience that this improvement is marginal at best for the types of source distributions encountered in clinical brain imaging. However, the code shows substantial advantage in suppressing uncorrelated backgrounds and the effects of highly penetrating gamma ray components in the source.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/24867/1/0000294.pd
Micromegas operation in high pressure xenon: charge and scintillation readout
The operational characteristics of a Micromegas operating in pure xenon at
the pressure range of 1 to 10 bar are investigated. The maximum charge gain
achieved in each pressure is approximately constant, around 4x10^2, for xenon
pressures up to 5 bar and decreasing slowly above this pressure down to values
somewhat above 10^2 at 10 bar. The MM presents the highest gains for xenon
pressures above 4 bar, when compared to other micropattern gaseous multipliers.
The lowest energy resolution obtained for X-rays of 22.1 keV exhibits a steady
increase with pressure, from 12% at 1bar to about 32% at 10 bar. The effective
scintillation yield, defined as the number of photons exiting through the MM
mesh holes per primary electron produced in the conversion region was
calculated. This yield is about 2x10^2 photons per primary electron at 1 bar,
increasing to about 6x10^2 at 5 bar and, then, decreasing again to 2x10^2 at 10
bar. The readout of this scintillation by a suitable photosensor will result in
higher gains but with increased statistical fluctuations.Comment: 22 pages, 11 figure
Time-Dependent Hartree-Fock simulation of the expansion of abraded nuclei
A recent interpretation of the caloric curve based on the expansion of the
abraded spectator nucleus is re-analysed in the framework of the Time-Dependent
Hartree-Fock (TDHF) evolution. It is shown that the TDHF dynamics is more
complex than a single monopolar collective motion at moderate energy. The
inclusion of other important collective degrees of freedom may lead to the
dynamical creation of hollow structure. Then, low density regions could be
locally reached after a long time by the creation of these exotic density
profiles. In particular the systematic of the minimum density reached during
the expansion (the so-called turning points) appears to be different.Comment: 30 Latex pages including 9 figure
Calculated gamma ray photofractions for well-type scintillation detectors
Monte Carlo calculations for the photofractions of well-type gamma ray scintillation crystals are described. Leakage of secondary gamma rays, bremsstrahlung and electrons is considered. Calculated photofractions are tabulated for two commonly used well crystals. Comparisons are made between photofractions for NaI, CsI and CaI2 scintillation crystals. Absorption and scattering within a homogeneous cylindrical source have been considered and results are given for aqueous solutions of monoenergetic sources.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/33471/1/0000876.pd
Axes determination for segmented true-coaxial HPGe detectors
A fast method to determine the crystallographic axes of segmented
true-coaxial high-purity germanium detectors is presented. It is based on the
analysis of segment-occupancy patterns obtained by irradiation with radioactive
sources. The measured patterns are compared to predictions for different axes
orientations. The predictions require a simulation of the trajectories of the
charge carriers taking the transverse anisotropy of their drift into account.Comment: 18 pages, 1 table, 31 figures; included background contribution to
the occupancy patterns and systematic uncertainties, results slightly change
- âŠ