33 research outputs found

    Small bowel MR enterography: problem solving in Crohn’s disease

    Get PDF
    Magnetic resonance enterography (MRE) is fast becoming the first-line radiological investigation to evaluate the small bowel in patients with Crohn’s disease. It can demonstrate both mural and extramural complications. The lack of ionizing radiation, together with high-contrast resolution, multiplanar capability and cine-imaging make it an attractive imaging modality in such patients who need prolonged follow-up. A key question in the management of such patients is the assessment of disease activity. Clinical indices, endoscopic and histological findings have traditionally been used as surrogate markers but all have limitations. MRE can help address this question. The purpose of this pictorial review is to (1) detail the MRE protocol used at our institution; (2) describe the rationale for the MR sequences used and their limitations; (3) compare MRE with other small bowel imaging techniques; (4) discuss how MRE can help distinguish between inflammatory, stricturing and penetrating disease, and thus facilitate management of this difficult condition

    Small bowel MRI in adult patients: not just Crohn’s disease—a tutorial

    Get PDF
    To provide an overview of less well-known small bowel and mesenteric diseases found at small bowel magnetic resonance (MR) enterography/enteroclysis and to review the imaging findings. MR enterography and enteroclysis are important techniques for evaluation of small bowel diseases. In most centres these techniques are primarily used in Crohn's disease, and most radiologists are familiar with these MRI findings. However, the knowledge of findings in other diseases is often sparse, including diseases that may cause similar clinical symptoms to those of Crohn's disease. We present a spectrum of less common and less well-known bowel and mesenteric diseases (e.g. internal hernia, intussusception, neuroendocrine tumour) from our small bowel MR database of over 2,000 cases. These diseases can be found in patients referred for bowel obstruction, abdominal pain or rectal blood loss. Further, in patients with (or suspected to have) Crohn's disease, some of these diseases (e.g. neuroendocrine tumour, familial Mediterranean fever) may mislead radiologists to erroneously diagnose active Crohn's disease. Radiologists should be familiar with diseases affecting the small bowel other than Crohn's disease, including diseases that may mimic Crohn's diseas

    Kaposi's Sarcoma-Associated Herpesvirus K7 Induces Viral G Protein-Coupled Receptor Degradation and Reduces Its Tumorigenicity

    Get PDF
    The Kaposi's sarcoma-associated herpesvirus (KSHV) genome encodes a G protein-coupled receptor (vGPCR). vGPCR is a ligand-independent, constitutively active signaling molecule that promotes cell growth and proliferation; however, it is not clear how vGPCR is negatively regulated. We report here that the KSHV K7 small membrane protein interacts with vGPCR and induces its degradation, thereby dampening vGPCR signaling. K7 interaction with vGPCR is readily detected in transiently transfected human cells. Mutational analyses reveal that the K7 transmembrane domain is necessary and sufficient for this interaction. Biochemical and confocal microscopy studies indicate that K7 retains vGPCR in the endoplasmic reticulum (ER) and induces vGPCR proteasomeal degradation. Indeed, the knockdown of K7 by shRNA-mediated silencing increases vGPCR protein expression in BCBL-1 cells that are induced for KSHV lytic replication. Interestingly, K7 expression significantly reduces vGPCR tumorigenicity in nude mice. These findings define a viral factor that negatively regulates vGPCR protein expression and reveal a post-translational event that modulates GPCR-dependent transformation and tumorigenicity

    Electron Microscopy as a Tool for Assessment of Anticoagulation Strategies during Extracorporeal Life Support : The Proof Is on the Membrane

    No full text
    Extracorporeal life support (ECLS) is fast becoming more common place for use in adult patients failing mechanical ventilation. Management of coagulation and thrombosis has long been a major complication in the use of ECLS therapies. Scanning electron microscopy (SEM) of membrane oxygenators (MOs) after use in ECLS circuits can offer novel insight into any thrombotic material deposition on the MO. In this pilot study, we analyzed five explanted MOs immediately after use in a sheep model of different acute respiratory distress syndrome (ARDS). We describe our methods of MO dissection, sample preparation, image capture, and results. Of the five MOs analyzed, those that received continuous heparin infusion showed very little thrombosis formation or other clot material, whereas those that were used with only initial heparin bolus showed readily apparent thrombotic material

    Primary retroperitoneal lymph node dissection as treatment for low-volume metastatic seminoma in a population-based cohort : the Swedish Norwegian testicular cancer group experience

    Get PDF
    Background and objective: There is an unmet need to avoid long-term morbidity associated with standard cytotoxic treatment for low-volume metastatic seminoma. Our aim was to assess the oncological efficacy and surgical safety of retroperitoneal lymph node dissection (RPLND) as treatment in a population-based cohort of metastatic seminoma patients with limited retroperitoneal lymphadenopathy. Methods: Sixty-two seminoma patients in Norway and Sweden were included in the cohort from 2019 to 2022. Patients with lymphadenopathy ≤3 cm, having primary clinical stage (CS) IIA/B or CS I with a relapse, were operated with uni- or bilateral template RPLND, open or robot assisted. The outcome measures included surgical complications as per Clavien-Dindo, and Kaplan-Meier survival estimates for 24-mo progression-free survival (PFS) and overall survival (OS). Key findings and limitations: In the cohort, 33 (53%) had CS I with a relapse during surveillance, six (10%) CS I with a relapse following adjuvant chemotherapy, and 23 (37%) initial CS IIA/B. Metastatic seminoma was verified in 58 patients (94%) with a median largest diameter of 18 mm (interquartile range [IQR] 13–24). Robot-assisted RPLND was performed in 40 patients (65%). Clavien-Dindo III complications were observed in three patients (5%); no grade ≥IV complications occurred. Eighteen patients (29%) received adjuvant chemotherapy after surgery. The median follow-up was 23 mo (IQR 16–30), and recurrence occurred in six patients (10%) after a median of 8 mo (IQR 4–14). PFS was 90% (95% confidence interval: 0.86–1) and OS was 100% at 24 mo. Conclusions and clinical implications: RPLND as primary treatment is an option for selected low-stage seminomas with a limited burden of disease, showing low complications and low relapse rates, with the potential to reduce long-term morbidity. Patient summary: In seminoma patients with limited metastatic spread, surgery is a treatment option offering an alternative to chemotherapy or radiation. This paper covers the first 62 patients operated in Norway and Sweden

    Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    Get PDF
    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P < 0.001), homogeneity of the luminal content (P < 0.001), delineation of the bowel-wall to the lumen (P < 0.001) and to the mesentery (P < 0.001) and artifacts (P < 0.001), leading to a significant better overall image quality (P < 0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P < 0.001) and wall to lumen delineation (P < 0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population
    corecore