859 research outputs found

    In vivo imaging of extracellular matrix remodeling by tumor-associated fibroblasts.

    Get PDF
    Here we integrated multiphoton laser scanning microscopy and the registration of second harmonic generation images of collagen fibers to overcome difficulties in tracking stromal cell-matrix interactions for several days in live mice. We show that the matrix-modifying hormone relaxin increased tumor-associated fibroblast (TAF) interaction with collagen fibers by stimulating beta1-integrin activity, which is necessary for fiber remodeling by matrix metalloproteinases

    Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

    Full text link
    We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.Comment: 35 pages, 21 figures, 8 table

    Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter

    Get PDF
    The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.Comment: 38 pages, 19 figures, 5 tables; author list changed; submitted to JINS

    Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    Get PDF
    A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques

    Azimuthal anisotropy of neutral pion production in Au+Au collisions at sqrt(s_NN) = 200 GeV: Path-length dependence of jet quenching and the role of initial geometry

    Full text link
    We have measured the azimuthal anisotropy of pi0's for 1 < pT < 18 GeV/c for Au+Au collisions at sqrt s_NN = 200 GeV. The observed anisotropy shows a gradual decrease in 3 < pT < 7 - 10 GeV/c, but remains positive beyond 10 GeV/c. The magnitude of this anisotropy is under-predicted, up to at least 10 GeV/c, by current perturbative QCD (pQCD) energy-loss model calculations. An estimate of the increase in anisotropy expected from initial-geometry modification due to gluon saturation effects and initial-geometry fluctuations is insufficient to account for this discrepancy. Calculations which implement a path length dependence steeper than what is implied by current pQCD energy-loss models, show reasonable agreement with the data.Comment: 384 authors, 6 pages text, 3 figures. Submitted to Phys. Rev. Lett. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are (or will be) publicly available at http://www.phenix.bnl.gov/papers.htm

    Ramucirumab in elderly patients with hepatocellular carcinoma and elevated alpha-fetoprotein after sorafenib in REACH and REACH-2

    Get PDF
    Background &amp; Aims: Limited data on treatment of elderly patients with hepatocellular carcinoma (HCC) increase the unmet need. REACH and REACH-2 were global phase III studies of ramucirumab in patients with HCC after prior sorafenib, where patients with alpha-fetoprotein (AFP) ≥400&nbsp;ng/mL showed an overall ssurvival (OS) benefit for ramucirumab. These post-hoc analyses examined efficacy and safety of ramucirumab in patients with HCC and baseline AFP&nbsp;≥&nbsp;400&nbsp;ng/mL by three prespecified age subgroups (&lt;65, ≥65 to &lt;75 and ≥75&nbsp;years). Methods: Individual patient data were pooled from REACH (baseline AFP ≥400&nbsp;ng/mL) and REACH-2. Kaplan-Meier and Cox proportional hazards regression methods (stratified by study) assessed OS, progression-free survival (PFS), time to progression (TTP) and patient-reported outcomes (Functional Hepatobiliary System Index-8 [FHSI-8] score). Results: A total of 542 patients (&lt;65&nbsp;years: n&nbsp;=&nbsp;302; ≥65 to &lt;75&nbsp;years: n&nbsp;=&nbsp;160; ≥75&nbsp;years: n&nbsp;=&nbsp;80) showed similar baseline characteristics between ramucirumab and placebo. Older subgroups had higher hepatitis C and steatohepatitis incidences, and lower AFP levels, than the &lt;65&nbsp;years subgroup. Ramucirumab prolonged OS in patients &lt;65&nbsp;years (hazard ratio [HR], 0.753; 95% CI 0.581-0.975), ≥65 to &lt;75&nbsp;years (0.602; 0.419-0.866) and ≥75&nbsp;years (0.709; 0.420-1.199), PFS and TTP irrespective of age. Ramucirumab showed similar overall safety profiles across subgroups, with a consistent median relative dose intensity ≥97.8%. A trend towards a delay in symptom deterioration in FHSI-8 with ramucirumab was observed in all subgroups. Conclusions: In this post-hoc analysis, ramucirumab showed a survival benefit across age subgroups with a tolerable safety profile, supporting its use in advanced HCC with elevated AFP, irrespective of age, including ≥75&nbsp;years

    Cold Nuclear Matter Effects on J/psi Yields as a Function of Rapidity and Nuclear Geometry in Deuteron-Gold Collisions at sqrt(s_NN) = 200 GeV

    Full text link
    We present measurements of J/psi yields in d+Au collisions at sqrt(s_NN) = 200 GeV recorded by the PHENIX experiment and compare with yields in p+p collisions at the same energy per nucleon-nucleon collision. The measurements cover a large kinematic range in J/psi rapidity (-2.2 < y < 2.4) with high statistical precision and are compared with two theoretical models: one with nuclear shadowing combined with final state breakup and one with coherent gluon saturation effects. To remove model dependent systematic uncertainties we also compare the data to a simple geometric model. We find that calculations where the nuclear modification is linear or exponential in the density weighted longitudinal thickness are difficult to reconcile with the forward rapidity data.Comment: 449 authors from 66 institutions, 6 pages, 3 figures. Submitted to Physical Review Letters. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are (or will be) publicly available at http://www.phenix.bnl.gov/papers.htm

    Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter

    Full text link
    Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.Comment: 26 pages, 16 figures, JINST style, changes in the author list, typos corrected, new section added, figures regrouped. Accepted for publication in JINS

    Transverse momentum dependence of J/psi polarization at midrapidity in p+p collisions at sqrt(s)=200 GeV

    Full text link
    We report the measurement of the transverse momentum dependence of inclusive J/psi polarization in p+p collisions at sqrt(s)=200 GeV performed by the PHENIX Experiment at RHIC. The polarization is studied in the helicity, Gottfried-Jackson, and Collins-Soper frames for p_T < 5 GeV/c and |y| < 0.35. The J/psi polarization in the helicity and Gottfried-Jackson frames is consistent with zero for all transverse momenta, with a slight (1.8 sigma) trend towards longitudinal polarization for transverse momenta above 2 GeV/c. No conclusion is allowed due to the limited acceptance in the Collins-Soper frame and the uncertainties of the current data. The results are compared to observations for other collision systems and center of mass energies and to different quarkonia production models.Comment: 384 authors from 62 institutions, 11 pages, 9 figures, 2 tables. v2 is expanded version submitted to Physical Review D. Plain text data tables for the points plotted in figures are available at http://www.phenix.bnl.gov/papers.htm
    corecore