171 research outputs found

    Challenges in QCD matter physics - The Compressed Baryonic Matter experiment at FAIR

    Full text link
    Substantial experimental and theoretical efforts worldwide are devoted to explore the phase diagram of strongly interacting matter. At LHC and top RHIC energies, QCD matter is studied at very high temperatures and nearly vanishing net-baryon densities. There is evidence that a Quark-Gluon-Plasma (QGP) was created at experiments at RHIC and LHC. The transition from the QGP back to the hadron gas is found to be a smooth cross over. For larger net-baryon densities and lower temperatures, it is expected that the QCD phase diagram exhibits a rich structure, such as a first-order phase transition between hadronic and partonic matter which terminates in a critical point, or exotic phases like quarkyonic matter. The discovery of these landmarks would be a breakthrough in our understanding of the strong interaction and is therefore in the focus of various high-energy heavy-ion research programs. The Compressed Baryonic Matter (CBM) experiment at FAIR will play a unique role in the exploration of the QCD phase diagram in the region of high net-baryon densities, because it is designed to run at unprecedented interaction rates. High-rate operation is the key prerequisite for high-precision measurements of multi-differential observables and of rare diagnostic probes which are sensitive to the dense phase of the nuclear fireball. The goal of the CBM experiment at SIS100 (sqrt(s_NN) = 2.7 - 4.9 GeV) is to discover fundamental properties of QCD matter: the phase structure at large baryon-chemical potentials (mu_B > 500 MeV), effects of chiral symmetry, and the equation-of-state at high density as it is expected to occur in the core of neutron stars. In this article, we review the motivation for and the physics programme of CBM, including activities before the start of data taking in 2022, in the context of the worldwide efforts to explore high-density QCD matter.Comment: 15 pages, 11 figures. Published in European Physical Journal

    Low-energy Calibration of XENON1T with an Internal 37^{37}Ar Source

    Get PDF
    A low-energy electronic recoil calibration of XENON1T, a dual-phase xenontime projection chamber, with an internal 37^{37}Ar source was performed. Thiscalibration source features a 35-day half-life and provides two mono-energeticlines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keVare measured to be (32.3±\pm0.3) photons/keV and (40.6±\pm0.5) electrons/keV,respectively, in agreement with other measurements and with NEST predictions.The electron yield at 0.27 keV is also measured and it is(68.03.7+6.3^{+6.3}_{-3.7}) electrons/keV. The 37^{37}Ar calibration confirms thatthe detector is well-understood in the energy region close to the detectionthreshold, with the 2.82 keV line reconstructed at (2.83±\pm0.02) keV, whichfurther validates the model used to interpret the low-energy electronic recoilexcess previously reported by XENON1T. The ability to efficiently remove argonwith cryogenic distillation after the calibration proves that 37^{37}Ar can beconsidered as a regular calibration source for multi-tonne xenon detectors.<br

    Effective Field Theory and Inelastic Dark Matter Results from XENON1T

    Get PDF
    In this work, we expand on the XENON1T nuclear recoil searches to study theindividual signals of dark matter interactions from operators up todimension-eight in a Chiral Effective Field Theory (ChEFT) and a model ofinelastic dark matter (iDM). We analyze data from two science runs of theXENON1T detector totaling 1\,tonne×\timesyear exposure. For these analyses, weextended the region of interest from [4.9, 40.9]\,keVNR_{\text{NR}} to [4.9,54.4]\,keVNR_{\text{NR}} to enhance our sensitivity for signals that peak atnonzero energies. We show that the data is consistent with the background-onlyhypothesis, with a small background over-fluctuation observed peaking between20 and 50\,keVNR_{\text{NR}}, resulting in a maximum local discoverysignificance of 1.7\,σ\sigma for the Vector\otimesVectorstrange_{\text{strange}}(VVsVV_s) ChEFT channel for a dark matter particle of 70\,GeV/c2^2, and1.8σ1.8\,\sigma for an iDM particle of 50\,GeV/c2^2 with a mass splitting of100\,keV/c2^2. For each model, we report 90\,\% confidence level (CL) upperlimits. We also report upper limits on three benchmark models of dark matterinteraction using ChEFT where we investigate the effect of isospin-breakinginteractions. We observe rate-driven cancellations in regions of theisospin-breaking couplings, leading to up to 6 orders of magnitude weaker upperlimits with respect to the isospin-conserving case.<br

    The Triggerless Data Acquisition System of the XENONnT Experiment

    Get PDF
    The XENONnT detector uses the latest and largest liquid xenon-based timeprojection chamber (TPC) operated by the XENON Collaboration, aimed atdetecting Weakly Interacting Massive Particles and conducting other rare eventsearches. The XENONnT data acquisition (DAQ) system constitutes an upgraded andexpanded version of the XENON1T DAQ system. For its operation, it reliespredominantly on commercially available hardware accompanied by open-source andcustom-developed software. The three constituent subsystems of the XENONnTdetector, the TPC (main detector), muon veto, and the newly introduced neutronveto, are integrated into a single DAQ, and can be operated both independentlyand as a unified system. In total, the DAQ digitizes the signals of 698photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPCare digitized twice, at ×10\times10 and ×0.5\times0.5 gain. The DAQ for the mostpart is a triggerless system, reading out and storing every signal that exceedsthe digitization thresholds. Custom-developed software is used to process theacquired data, making it available within O(10 s)\mathcal{O}\left(10\text{ s}\right)for live data quality monitoring and online analyses. The entire system withall the three subsystems was successfully commissioned and has been operatingcontinuously, comfortably withstanding readout rates that exceed 500\sim500 MB/sduring calibration. Livetime during normal operation exceeds 99%99\% and is90%\sim90\% during most high-rate calibrations. The combined DAQ system hascollected more than 2 PB of both calibration and science data during thecommissioning of XENONnT and the first science run.<br

    Search for New Physics in Electronic Recoil Data from XENONnT

    Get PDF
    We report on a blinded analysis of low-energy electronic recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 ton liquid xenon target reduced the background in the (1, 30) keV search region to (15.8±1.3)  events/(ton×year×keV), the lowest ever achieved in a dark matter detector and ∼5 times lower than in XENON1T. With an exposure of 1.16 ton-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter

    Low-energy calibration of XENON1T with an internal 37^{{\textbf {37}}}Ar source

    Get PDF
    A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal 37Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3±0.3) photons/keV and (40.6±0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0+6.3−3.7) electrons/keV. The 37Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83±0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that 37Ar can be considered as a regular calibration source for multi-tonne xenon detectors
    corecore